This paper proposed a theoretical treatment to study underwater wireless optical communications (UWOC) system with different modulation schemes by multiple input-multiple output (MIMO) technology in coastal water. MIMO technology provides high-speed data rates with longer distance link. This technique employed to assess the system by BER, Q. factor and data rate under coastal water types. The reliability of the system is examined by the techniques of 1Tx/1Rx, 2Tx/2Rx, 3Tx/3Rx and 4Tx/4Rx. The results shows the proposed technique by MIMO can get the better performance compared with the other techniques in terms of BER. Theoretical results were obtained to compare between PIN and APD
Abstract:
Under the state scenario, fiscal policy will not be able to use the oil surpluses optimally and economically and society, as long as these surpluses are not directed by public expenditure towards new productive investments and by following the path of fiscal policy after one year 2003 and until 2013 we note that it is based on the method of spending (excessive) consumption, and did not take any action towards the budget deficit planned at the beginning of the fiscal year, and the actual surplus at the end of the fiscal year, which represents the highest expenditure in the budget, Salaries and wages of workers in various government agencies with the expansion of spending on the security side.&n
... Show MoreThere is a relationship between the sizes of urban centers and regional
development, concerning the role that these centers are playing in
developmental process.
The research assume that the urban system in the governorate, has
been affected by the external environment due to the religious dominance of
Kerbla city.
The research is composed of three sections, the first is a theoretical
background, which focus upon the general directions of the models and
theories that have a relationship with the subject. The second is a practical
part aims at determination the characteristics of the sizes of the cities in the
governorate. Depending upon of previous part, i.e., the practical part section three deals with
The reticuloendothelial system (RES) play an important role in immunity against bacterial infection and Klebsiella pneumoniae one of the most common causes of hospital-acquired infections. Dextran70 (D70), a polysaccharide, may alter functions of this system through changing many biological activities in the tissues.
This paper is concerned with the blow-up solutions of a system of two reaction-diffusion equations coupled in both equations and boundary conditions. In order to understand how the reaction terms and the boundary terms affect the blow-up properties, the lower and upper blow-up rate estimates are derived. Moreover, the blow-up set under some restricted assumptions is studied.
A mathematical eco-epidemiological model consisting of harvested prey–predator system involving fear and disease in the prey population is formulated and studied. The prey population is supposed to be separated into two groups: susceptible and infected. The susceptible prey grows logistically, whereas the infected prey cannot reproduce and instead competes for the environment’s carrying capacity. Furthermore, the disease is transferred through contact from infected to susceptible individuals, and there is no inherited transmission. The existence, positivity, and boundedness of the model’s solution are discussed. The local stability analysis is carried out. The persistence requirements are established. The global behavior of th
... Show MoreThe mark at the Children's Theater did not receive as much attention as in the adult theater, despite the great attention given to its visual system, but some of the directors of the Children's Theater approached the application of the same system of marking in the adult theater, without limiting a certain mechanism that identifies the mechanisms of mark operation and the modalities of its transformation in the visual display system, which called on the researcher to shed light in this study on the scientific shift in the visual display system and its functions in the children's theater. The researcher formulated a title for his research (the mark transformation of the visual display system in the chi
... Show MoreExperimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre
... Show MoreIn this paper, we deal with a dynamical system that can demonstrate a chaotic attractor of Rossleroscillator. We simulate the Rosslerequations numerically then we investigate the model experimentally. Numerically, the Rossler parameter a and b were fixed and c was changed.The evolution of the system exhibits period, period-doubling, second period doubling, and chaos when control parameters are changed. This evolution can be seen by analyze the time series, the bifurcation diagrams and phase space. Experimentally, the evolution of the system exhibited the same numerical behavior by changing the resistance (Rv) in Rossler circuit that represent as control parameter.
In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show More