<p>Photovoltaic (PV) systems are becoming increasingly popular; however, arc faults on the direct current (DC) side are becoming more widespread as a result of the effects of aging as well as the trend toward higher DC voltage levels, posing severe risk to human safety and system stability. The parallel arc faults present higher level of current as compared with the series arc faults, making it more difficult to spot the series arc. In this paper and for the aim of condition monitoring, the features of a DC series arc fault are analyzed by analysing the arc features, performing model’s simulation in PSCAD, and carrying out experimental studies. Various arc models are simulated and investigated; for low current arcs, the heuristic model is used where a set of parameters established. Moreover, the heuristic model’s simulated arc has been shown to be compatible with the experimental data. The features of arc noise in the electrode separation region and steady-arcing states with varied gap widths are investigated. It has been discovered that after an arc fault occurs, arc noise increases, notably in the frequency range below 50 kHz; where this property is useful for detecting DC series arc faults. Besides that, variations in air gap width are more sensitive to frequencies under 5 kHz.</p>
Abstract:
The researcher shed light on a diet in Iraq before 2003 became in this period. And how the ration card has a variety of vocabulary and cover the need of the population of commodities and have a key role in saving Iraq from a real crisis in the period of economic siege, especially in light of the State's direction to support the agricultural sector, which in that period able to fill half of the market needs of food the basic. As well as providing strategic storage at the Ministry of Commerce enough for six months But after the events of 2003 and the crises that hit the country and the unstable security situation began to rise voices calling for reform of the ration card system as a system that is a burden on the
... Show MoreThe removal of fluoride ions from aqueous solution onto algal biomass as biosorbent in batch and continuous fluidized bed systems was studied. Batch system was used to study the effects of process parameters such as, pH (2-3.5), influent fluoride ions concentration (10- 50 mg/l), algal biomass dose (0–1.5 g/ 200 ml solution), to determine the best operating conditions. These conditions were pH=2.5, influent fluoride ions concentration= 10 mg/l, and algal biomass dose=3.5 mg/l. While, in continuous fluidized bed system, different operating conditions were used; flow rate (0.667- 0.800 l/min), bed depth (8-15 cm) corresponded to bed weight of (80- 150 g). The results show that the breakthrough time increases with the inc
... Show MoreThis paper studies the oscillation properties and asymptotic behavior of all solutions of the 2×2 system of second-order half-linear neutral differential equations. Four results are obtained in this research. The first and second results are auxiliary results while the third and fourth results are main results. All possible cases of non-oscillating bounded solutions for this system are estimated and analyzed. It is noted that the parameters that affect the volatility of the solutions are Qi,Ri on the one hand and r1 and r2 on the other hand. For this purpose, and through investigation, it is shown that there are only fourteen possible cases of non-oscillating bounded solutions for this system, so all these cases must be treated, in the fir
... Show MoreGas lift is one of the most important artificial lift methods for increasing oil production, as wells often require this method after the reservoir's energy has decreased. In this research, an optimal gas lift system is designed for five horizontal wells in the Ahdab oil field, which suffers from low production. At the same time, water cut in some of these wells reaches 66%, while the productivity index is low in others, which makes the challenges clear, and a deep analysis is needed to find an optimal system. The Pipesim program is used to design the optimal gas lift system, which contains features that facilitate the implementation of the appropriate design and provide the ability to analyze and determine the optimal design v
... Show MoreThe present study aims to present a proposed realistic and comprehensive cyber strategy for the Communications Directorate for the next five years (2022-2026) based on the extent of application and documentation of cybersecurity measures in the Directorate and the scientific bases formulating the strategy. The present study is significant in that it provides an accurate diagnosis of the capabilities of the cyber directorate in terms of strengths and weaknesses in its internal environment and the opportunities and threats that surround it in the external environment, based on the results of the assessment of the reality of cybersecurity according to the global Cybersecurity index, which provides a strong basis for building its strategic dire
... Show MoreBackground: Oral squamous cell carcinoma (OSCC) remains a lethal and deforming disease, with a significant mortality and a rising incidence in younger and female patients. It is thus imperative to identify potential risk factors for OSCC and oral PMDs and to design an accurate data collection tool to try to identify patients at high risk of OSCC development. 14 factors consistently found to be associated with the pathogenesis of OSCC and oral PMDs. Eight of themwere identified as high risk (including tobacco, alcohol, betel quid, marijuana, genetic factors, age, diet and immunodeficiency) and 6 low risk (such as oral health, socioeconomic status, HPV, candida infection, alcoholic mouth wash and diabetes) were stratified according to severit
... Show More