In practical engineering problems, uncertainty exists not only in external excitations but also in structural parameters. This study investigates the influence of structural geometry, elastic modulus, mass density, and section dimension uncertainty on the stochastic earthquake response of portal frames subjected to random ground motions. The North-South component of the El Centro earthquake in 1940 in California is selected as the ground excitation. Using the power spectral density function, the two-dimensional finite element model of the portal frame’s base motion is modified to account for random ground motions. A probabilistic study of the portal frame structure using stochastic finite elements utilizing Monte Carlo simulation is presented using the finite element program ABAQUS. The dynamic reliability and probability of failure of stochastic and deterministic structures based on the first-passage failure were examined and evaluated. The results revealed that the probability of failure increases due to the randomness of stiffness and mass of the structure. The influence of uncertain parameters on reliability analysis depends on the extent of variance in structural parameters.
Bored piles settlement behavior under vertical loaded is the main factor that affects the design requirements of single or group of piles in soft soils. The estimation of bored pile settlement is a complicated problem because it depends upon many factors which may include ground conditions, validation of bored pile design method through testing and validation of theoretical or numerical prediction of the settlement value. In this study, a prototype single and bored pile group model of arrangement (1*1, 1*2 and 2*2) for total length to diameter ratios (L/D) is 13.33 and clear spacing three times of diameter, subjected to vertical axial loads. The bored piles model used for the test was 2000
... Show MoreThe dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (μCT) was used to quantify apparent voids within the root-canal space. The data were statistically analys
... Show MoreThe diagnoses system of varicose disease has a good level of performance due to the complexity and uniqueness in patterns of vein of the leg. In addition, the patterns of vein are internal of the body, and its features are hard to duplicate, this reason make this method not easy to fake, and thus make it contains of a good features for varicose disease diagnoses. The proposed system used more than one type of algorithms to produce diagnoses system of varicose disease with high accuracy, in addition, this multi-algorithm technique based on veins as a factor to recognize varicose infection. The obtained results indicate that the design of varicose diagnoses system by applying multi- algorithms (Naïve Bayes and Back-Propagation) produced new
... Show MoreIn this paper it is required to enhance the performance of a mechanical system (here: a Hoisting System) where it is preferred to lift a different payloads with approximately the same speed of lifting and keeping at the same time the good performance, and this of course needs some intelligence of the system which will be responsible on measuring the present load and taking into account the speed and performance desired in order to achieve the requirements or the criteria. The process therefore is a Mechatronics System design which includes a measuring system, a control or automation technique, and an actuating system. The criteria built here in this research using a given Hoist system's characteristics and parameters and changing one of
... Show MoreFumonisin B1 is toxic secondary metabolites compound produced by Fusarium spp. on maize and maize products causes health problems to human and animal. Therefore, this research is planned to study the effect of FB1 on the expression of TLR-2 & 4 in liver and kidney cells of mice. Four group of male mice were orally administrated with single dose of FB1 toxin as the following: 0 ppb, 800 ppb, 1200 ppb and 1600 ppb. After two weeks all animals were sacrificed, liver and kidney autopsies were taken and the level of TLR-2 & 4 detected in each four group by immunohistochemistry technique (IHC). According to the IHC examination of groups (1, 2, 3 and 4) strong expression of TLR2 in liver and kidney were (0%, 33.3%, 100%, 100%), respectively. This
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronid
... Show MoreIncremental sheet metal forming process is an advanced flexible manufacturing process to produce various 3D products without using dedicated tool as in conventional metal forming. There are a lot of process parameters that have effect on this process, studying the effect of some parameters on the strain distributions of the product over the length of deformation is the aim of this study.
In order to achieve this goal, three factors (tool forming shape, feed rate and incremental step size) are examined depending on three levels on the strain distributions over the wall of the product. Strain measurement was accomplished by using image processing technique using MATALB program. The significance of the control factors are explored u
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronidazole. The data
... Show More