Anti-Neutrophil Cytoplasmic Antibodies (ANCA) are a heterogeneous group of autoantibodies with a broad spectrum of clinically associated diseases. The diagnostic value is established for Proteinase 3 (PR3)-ANCA as well as Myeloperoxidase (MPO)-ANCA. To estimate the frequency of anti-neutrophile cytoplasmic antibodies (ANCA) in sera from a group of Iraqi patients with some autoimmune diseases compared with a healthy control group. Serum samples were collected from one hundred patient, 47 males and 53 females; with age range of 16-70 years; 20 specimens from patients with systemic lupus erythematosus (SLE), 30 from patients with ulcerative colitis (UC), and 50 from patients with rheumatoid arthritis (RA). A group of 40 apparently healthy b
... Show MoreThe Gender study is consider one of the concepts which the Postmodernism reached
after the end of Modernism, where the first one has limited the criticism study choices before
the second after closed many doors of subjects which was enriched by researches.
It is pretty clear that the root of this concept belongs to the Linguistics which provided
the Criticism with a countable reasons of it is growth.
The attention in the study of gender in Feminine Literature and Criticism increased in
Arabic studies since the early years of twenty one century, so this research is presented to be
an introduction to this subject which could pave the way to more studies.
In addition to the Gender studies this research deals with ano
The goal of this work is demonstrating, through the gradient observation of a of type linear ( -systems), the possibility for reducing the effect of any disturbances (pollution, radiation, infection, etc.) asymptotically, by a suitable choice of related actuators of these systems. Thus, a class of ( -system) was developed based on finite time ( -system). Furthermore, definitions and some properties of this concept -system and asymptotically gradient controllable system ( -controllable) were stated and studied. More precisely, asymptotically gradient efficient actuators ensuring the weak asymptotically gradient compensation system ( -system) of known or unknown disturbances are examined. Consequently, under convenient hypo
... Show MoreIn this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).
This paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show MoreThe research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.
Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL
Sensibly highlighting the hidden structures of many real-world networks has attracted growing interest and triggered a vast array of techniques on what is called nowadays community detection (CD) problem. Non-deterministic metaheuristics are proved to competitively transcending the limits of the counterpart deterministic heuristics in solving community detection problem. Despite the increasing interest, most of the existing metaheuristic based community detection (MCD) algorithms reflect one traditional language. Generally, they tend to explicitly project some features of real communities into different definitions of single or multi-objective optimization functions. The design of other operators, however, remains canonical lacking any inte
... Show More