The study investigated the behaviour of asphalt concrete mixes for aggregate gradations, according to the Iraqi specification using the Bailey method designed by an Excel spreadsheet. In mixing aggregates with varying gradations (coarse and fine aggregate), The Bailey method is a systematic methodology that offers aggregate interlocking as the backbone of the framework and a controlled gradation to complete the blends. Six types of gradation are used according to the bailey method considered in this study. Two-course prepared Asphalt Concrete Wearing and Asphalt Concrete binder, the Nominal Maximum Aggregate Sizes (NMAS) of the mixtures are 19 and 12.5 mm, respectively. The total number of specimens was 240 for both layers (15 samples) for each Chosen Unit Weight (CUW). The Marshall Test results show the increase in stability and decrease in flow and bulk density when the rise in CUW for both courses. In volumetric properties, VMA increases when the increase in CUW. When an increase in CUW air void increases gradually. The permanent deformation for the coarse aggregate (95, 100, 105% CUW) has more resistances than the fine aggregate (80, 85, 90%) wearing and binder coarse. The CUW (105%) blend of wearing, and binder course has a high value of stability and resistance to permanent deformation (11.9, 11.1 kN). The CUW above mentioned is considered a good design aggregate structure and produces improvement to the Marshall properties, leading to better performance for pavement roads and higher resistance to distresses.
In the present work effect of recycled heating and cooling on the values of concrete compressive strength due to high temperature of 4000C was studied.
The tests show that the percent of reduction in compressive strength of the samples which exposed to a temperature of 4000C for one cycle was 32.5%, while the reduction was 52.7% for the samples which were exposed to recycled heating and cooling of ten times .
Moreover a study of the effect of specimen sizes on the percentages of compressive strength reduction due to high temperature
... Show MoreThis paper aims to propose a hybrid approach of two powerful methods, namely the differential transform and finite difference methods, to obtain the solution of the coupled Whitham-Broer-Kaup-Like equations which arises in shallow-water wave theory. The capability of the method to such problems is verified by taking different parameters and initial conditions. The numerical simulations are depicted in 2D and 3D graphs. It is shown that the used approach returns accurate solutions for this type of problems in comparison with the analytic ones.
The aim of the study is to identify the stage of both decentralized performance and organizational confidence with through those responsible the decentralized work of officials in organizing and managing local championships affiliated with the Iraqi Athletics Federation from their perspective. The study employed a descriptive approach using a correlational method on a sample of those managing local championships of the Iraqi Athletics Federation, including members , coaches, referees, and the president of the central administrative board, as well as the members and presidents of the subfederations for the sports (2020/2021).
The present study aimed to identify the exact location and its relation to cognitive
method (risk_caution) to university students. The sample consisted of (300) students who
were chosen randomly and equally. The study results indicated that students possess an
internal exact location and they also use risk cognitive method. The study also indicated that
there is a prophesies which is an exact location for others to reach to caution cognitive
method. Depending on these results, the study recommended to benefit from the results of the
study variables and from the measurement of the exact location and method of cognitive
(risk_caution) to identify male and female students and especially by consulting units at
college
In this work, we construct projectively distinct (k,3)-arcs in the projective plane PG(2,9) by applying a geometrical method. The cubic curves have been been constructed by using the general equation of the cubic. We found that there are complete (13,3)-arcs, complete (15,3)-arcs and we found that the only (16,3)-arcs lead to maximum completeness
In this paper a modified approach have been used to find the approximate solution of ordinary delay differential equations with constant delay using the collocation method based on Bernstien polynomials.
Abstract
The project of balad's major sewerage system is one of the biggest projects who is still in progress in salahulddin province provincial - development plan that was approved in 2013 . This project works in two parts ; the 1st is installing the sewerage networks (both of heavy sewerage & rain sewerage) and the 2nd is installing the life – off units (for heavy sewerage & rain sewerage , as well) . the directorate of salahuiddin is aiming that at end of construction it will be able to provide services for four residential quarters , one of the main challenges that project's management experience is how to achieve thes
... Show MoreHartree-Fock calculations for even-even Tin isotopes using
Skyrme density dependent effective nucleon-nucleon interaction are
discussed systematically. Skyrme interaction and the general formula
for the mean energy of a spherical nucleus are described. The charge
and matter densities with their corresponding rms radii and the
nuclear skin for Sn isotopes are studied and compared with the
experimental data. The potential energy curves obtained with
inclusion of the pairing force between the like nucleons in Hartree-
Fock-Bogoliubov approach are also discussed.
The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.
Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In
... Show More