Background: Coronary artery disease (CAD) is one of the leading causes of death worldwide. Clopidogrel, antiplatelet drug, has been widely used for management of CAD. Arylesterase, the activity of Paraoxonase-1 (PON-1), is mainly contributed in the biotransformation of clopidogrel to its active thiol form. The purpose of this study was to investigate the effect of receiving clopidogrel drug on the arylesterase activities in CAD patients. The effect of receiving clopidogrel drug on the antioxidant activity of arylesterase was also monitored by determination of malondialdehyde (MDA) level. Methods: One hundred CAD patients, who were followed-up for 5 days after reciving clopidogrel, and 50 healthy volunteers were included in our study. The activities of arylesterase using two (phenyl acetate and p-nitrophenyl acetate) substrates, lipid profile, MDA, and total protein concentration (Tp) were determined spectrophotometrically. Results: PON-1 arylesterase activities, HDL-C, and Tp were significantly decreased (P<0.0001) in patients with CAD before receiving clopidogrel drug (CAD-pre-Clp) compared to baseline (non-CAD) and the levels of these parameters were returned to baseline (P>0.05) after 5 days of receiving clopidogrel (CAD-post-Clp).
This study deals with the elimination of methyl orange (MO) from an aqueous solution by utilizing the 3D electroFenton process in a batch reactor with an anode of porous graphite and a cathode of copper foam in the presence of granular activated carbon (GAC) as a third pole, besides, employing response surface methodology (RSM) in combination with Box-Behnk Design (BBD) for studying the effects of operational conditions, such as current density (3–8 mA/cm2), electrolysis time (10–20 min), and the amount of GAC (1–3 g) on the removal efficiency beside to their interaction. The model was veiled since the value of R2 was high (>0.98) and the current density had the greatest influence on the response. The best removal efficiency (MO Re%)
... Show MoreThe study was conducted in the fields of the Department of Horticulture and Landscaping/College of Agriculture/University of Al-Qadisiyah/Al-Nouriah district - for the 2019-2020 agricultural season to study the effect of spraying with organic sulfur and hydrogen peroxide on the growth and yield of onions, Allium cepa L, where the study included two factors: the first factor was spraying organic sulfur at concentration (0, 2)., 4 ml. L-1) and symbol S1, S2, S3 and the second factor spraying with hydrogen peroxide at a concentration (0, 2, 4 ml. L-1) and symbolized by B1, B2, B3 and the interaction between them. A factorial experiment was conducted according to the randomized complete b
Series of new complexes of the type [M2 (L)Cl4 ] are prepared from the new ligand[N1 ,N4 -bis(benzo[d]thiazol-2- yl)succinamide (L) derived from ethan-1,2-dicarbonyl chloride and 2-aminobenzothiozole,where, M= Ni(ii), Cu(ii) and Zn(ii) alsocomplexes of mix-ligands, the type [M(L)(8-HQ)]Cl, where, M = Ni(ii), Cu(ii) and Zn(ii),8-HQ= 8-Hydroxyquinoline. Chemical forms are obtained from their 1 H, 13CNMR, Mass spectra (for (L)), FT-IR and U.V spectrum, melting point, molar conduct.Using flame (AA), % M is determined in the complexes.The content of C, H, N and S in the (L) and its complexes was specified. Magnetic susceptibility and thermal analysis (TGA) of prepared compounds were measured.The propose geometry for all complexes[M2 (L)Cl4 ] wa
... Show MoreThe preparation, spectroscopic characterisation of complexes derived from the mixed ligands with CdII, ZnII and CoII metal ions with Schiff base, Dithiocarbamates (DTCs) and 8-Hydroxyquinoline are reported. The compounds that prepared have been defined via; chloride content, F.T-IR, UV-Vis 1H-NMR spectroscopy and C.H.N.S, as well as conductance and magnetic susceptibility.All data which collected from such methods specified complexes with 6 coordinates in solution and solid states. The biologicalactivity that is related to all the prepared compounds which were screened for their antimicrobial activitiesagainst (G+ and (G- )). The data that collected from biological activity indicate that complexes will have extra activity against such teste
... Show MoreInvestigating the thermal and electrical gains and efficiencies influence the designed photovoltaic thermal hybrid collector (PVT) under different weather conditions. The designed system was manufactured by attaching a fabricated cooling system made of serpentine tubes to a single PV panel and connecting it to an automatic controlling system for measuring, monitoring, and simultaneously collecting the required data. A removable glass cover had been used to study the effects of glazed and unglazed PVT panel situations. The research was conducted in February (winter) and July (summer), and March for daily solar radiation effects on efficiencies. The results indicated that electrical and thermal gains increased by the incre
... Show MoreA filed experiment was carried out at one of the private farms at Al-Suwaira District, Wasit Governorate during the spring season 2021, in order to evaluate the effect of adding Fulyzme plus (biofertilizer) and the foliar application of green tea extract (organic nutrient) on growth and yield of pepper plant cv. California wonder. A factorial experiment (43) was carried out using RCBD Design with three replicates. The Fulyzme plus treatment was applied with four concentrations (0, 10, 20. and 30 g. L-1). The foliar application of green tea extract was applied with three concentrations which were 0, 2 and 4 ml. L-1. Results revealed significant effects of Fulyzme plus at 30 g. L-1 and the foliar application of green tea extract at
... Show MoreAn in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still res
... Show More