We consider the problem of calibrating range measurements of a Light Detection and Ranging (lidar) sensor that is dealing with the sensor nonlinearity and heteroskedastic, range-dependent, measurement error. We solved the calibration problem without using additional hardware, but rather exploiting assumptions on the environment surrounding the sensor during the calibration procedure. More specifically we consider the assumption of calibrating the sensor by placing it in an environment so that its measurements lie in a 2D plane that is parallel to the ground. Then, its measurements come from fixed objects that develop orthogonally w.r.t. the ground, so that they may be considered as fixed points in an inertial reference frame. Moreover, we consider the intuition that moving the distance sensor within this environment implies that its measurements should be such that the relative distances and angles among the fixed points above remain the same. We thus exploit this intuition to cast the sensor calibration problem as making its measurements comply with this assumption that “fixed features shall have fixed relative distances and angles”. The resulting calibration procedure does thus not need to use additional (typically expensive) equipment, nor deploy special hardware. As for the proposed estimation strategies, from a mathematical perspective we consider models that lead to analytically solvable equations, so to enable deployment in embedded systems. Besides proposing the estimators we moreover analyze their statistical performance both in simulation and with field tests. We report the dependency of the MSE performance of the calibration procedure as a function of the sensor noise levels, and observe that in field tests the approach can lead to a tenfold improvement in the accuracy of the raw measurements.
The influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.
Objective: The study aims to evaluate nurses' knowledge toward care of unconscious adult patients and identify the relationship between nurses’ knowledge toward care of unconscious adult patient and their demographic characteristics of age, gender, Marital Status, level of qualification and years of experience. Methodology: A descriptive study (quantitative design) was carried out by using quasi experimental design to study nurses' knowledge, attitudes and practices toward care of unconscious adult patients at teaching hospitals in Al-Hilla City from September 2018 up to June 2019. A purposively sample has been chosen in which included 60 nurses who work in ICUs within two hospitals (Imam Al-Sadiq teaching hospital and Al-Hilla general
... Show More<p>The demand for internet applications has increased rapidly. Providing quality of service (QoS) requirements for varied internet application is a challenging task. One important factor that is significantly affected on the QoS service is the transport layer. The transport layer provides end-to-end data transmission across a network. Currently, the most common transport protocols used by internet application are TCP (Transmission Control Protocol) and UDP (User Datagram Protocol). Also, there are recent transport protocols such as DCCP (data congestion control protocol), SCTP (stream congestion transmission protocol), and TFRC (TCP-friendly rate control), which are in the standardization process of Internet Engineering Task
... Show MoreBackground: The aim of this study was to evaluate the expression of ?broblast growth factor-2 and Heparanase in oral squamous cell carcinoma, and to correlate the two studied marker with each other and with clinicopathologicalfinding including grade, stage. Methods: Sections of 30 formalin-fixed paraffin embedded blocks specimens of oral squamous cell carcinoma were immunostained to assess the expression of ?broblast growth factor-2 and Heparanse in oral squamous cell carcinoma cases. Results: The expression of fibroblast growth factor-2 and Heparanase were positive in all oral squamous cell carcinoma cases (100%). The positive expression of fibroblast growth factor-2 was significantly correlated with tumor site (p=0.016),and clinical pres
... Show MoreIn this paper, we deal with a dynamical system that can demonstrate a chaotic attractor of Rossleroscillator. We simulate the Rosslerequations numerically then we investigate the model experimentally. Numerically, the Rossler parameter a and b were fixed and c was changed.The evolution of the system exhibits period, period-doubling, second period doubling, and chaos when control parameters are changed. This evolution can be seen by analyze the time series, the bifurcation diagrams and phase space. Experimentally, the evolution of the system exhibited the same numerical behavior by changing the resistance (Rv) in Rossler circuit that represent as control parameter.
This research has been applied on 100 children (age 4 – 6 years) from three kindergartens distributed on basis of 43 children from the college of Education for women kindergarten (A) , 27 children from the governmental Al- Mustafa kindergarten (B) , and 30 children from the private Al – Baraom kindergarten (C) . Details concerning their school meals, already prepared at home , have been analyzed according to their dietary components taken from the tables of the dietary values .The statistical analysis results have shown no significant difference (p< 0.01) in the intake of energy , protein and thiamin between the children of A and C kindergartens while these children have significantly recieved higher amounts of the above nutrien
... Show MoreIn this paper, tunable optical band-pass filters based on Polarization Maintaining Fiber –Mach Zehnder Interferometer presented. Tunability of the band-pass filter implemented by applying different mechanical forces N on the micro-cavities splicing regions (MCSRs). The micro-cavity formed by using three variable-lengths of single-mode polarization-maintaining fiber with (8, 16, 24) cm lengths, splice between two segments of (SMF-28) with (26, 13) cm lengths, using the fusion splicing technique. Ellipsoidal shape micro-cavities experimentally achieved parallel to the propagation axis having dimensions between (12-24) μm of width and (4-12) μm of length. A micro-cavity with width and length as high as 24 μm and 12 μ
... Show Moreتناولنا في هذه الدراسة التأكيد على تطوير المناهج الدراسية بأتجاه تنمية قيم التسامح والتعايش السلمي ، لان ثقافة التسامح باتت من الضرورات الملحة التي يفرضها الواقع الراهن لمواجهة العنف المجتمعي ، مما يوجب الحرص على ترسيخ القيم الانسانية ، لان التسامح من الصفات التي تحبها النفوس وتنجذب اليها القلوب .
والقيم الاخلاقية والسلوكية كالتسامح وغيرها ، من الامور الرئيسية لعمليتي التربية والتعليم في المدارس وال
... Show MoreThe expression of the Proprotein Convertase Subtilisin/Kexin Type 9 gene (PCSK9) is inextricably related to lipid levels and a risk of atherosclerotic coronary artery disease (ASCAD). The present study aims to measure the quantity of PCSK9 gene expression and the effect of methylation on its expression level taking part in the pathogenesis of acute coronary artery disorder.
A current study included 150 subjects from the Iraqi population, 100 ASCAD patients and 50 healthy controls. The concentration of PCSK9 in each serum sample was determined by the ELISA technique, the expression levels of the PCSK9 gene in whole blood were estimated by RT-qPCR – Quantitative Reverse Transcription PCR method, and DNA
... Show More