Background: Lateral sinus augmentation and simultaneous insertion of dental implants is a highlypredictable procedure and associated with high rate of implants success.Aims: To evaluate implant stability changes following maxillary sinus augmentation utilizing deproteinizedbovine bone alone or mixed with platelet-rich fibrin.Materials and Methods: A total of 34 lateral sinus augmentation procedures were performed and 50 dentalimplants simultaneously installed. The lateral sinus augmentation cases were allocated randomly into 3groups: Group A comprised 13 procedures and 21 dental implants utilizing solely deproteinized bovine bone.Group B involved 10 cases and 16 dental implants using deproteinized bovine bone mixed with leukocyteand platelet-rich fibrin. Group C included 11 operations and 13 dental implants employing deproteinizedbovine bone mixed with advanced platelet-rich fibrin. Resonance frequency analysis test was performedimmediately after implant installation and 24 weeks postoperatively for the measurement of the implantstability.Results: Implant stability quotient values increased significantly for all study groups 24 weeks after dentalimplants installation (P= 0.001). The implant stability quotient at T1 (day of implant installation) was 56.93±12.01 for group A, 58.34 ±12.82 for group B, and 61.35 ±8.47 for group C. The implant stability quotientat T2 (24 weeks after implant insertion) was 69.17 ±5.10, 69.43 ±5.32, and 68.50 ±7.44, respectively.Conclusion: The addition of leukocyte and platelet-rich fibrin or advanced platelet-rich fibrin to the bovinebone for sinus floor augmentation did not increased the implant stability quotient value in comparison to thebovine bone alone.
Objectives: to evaluate the role of conservative, decompression, spine fixation in management of closed spinal injury.
Methods: The study was conducted at Specialized Surgical hospital and Al-Kadhemayia Teaching Hospital, in the period between July 2003 and July 2005.The study included 61 patients categorized Into many groups according level of vertebral injury (cervical, cervicodorsal, dorsal, dorsolumbar, Lumbar and lumbosacral), type of injury (compressed fracture, burst fracture and fracture dislocation) And according the severity into three groups as G1( complete motor paralysis and sensory loss ) G2 ( complete motor paralysis and incomplete sensory loss) and G3 ( incomplete motor paralysis And incomplete sensory loss ).The metho
The research aims to define the images of financial aid that it provides within their tasks (central banks to governments) and how it can affect the indicators of banking stability, as well as monitoring the levels of banking stability in the Iraqi economy through the indicators used by the Central Bank of Iraq, and the importance of research in banking stability lies in Iraq, because any decrease in the movement of the aggregate banking stability index will reflect negatively on the financial sector in Iraq. Therefore, the Central Bank sought to provide financial aid to the government through a group of components, some of which are represented by initiatives that contribute to revitalizing the national economy and the other hel
... Show MoreThe analytical results of the failure types of six limestone islands in the Ha Long bay of Vietnam have been identified. The calculated results of safety factor for 03 plane failure blocks lie within 0.9 and 2, have high potential failure. The analytical results have been also simulated these islands in three-dimensional space and have been also analyzed their potential failure on the fracture surfaces. The results obtained in this paper have important significance for planning and development of the Ha Long bay area, as World Natural Heritage, Quang Ninh province of Vietnam.
The research work was conducted to investigate the effect of oral administration of water extract of black pepper at doses of (1, 5) mg/kg body weight for two weeks daily by determining the genotoxic effect (mitotic index), evaluation of immunological effect (IgG, IgM, IgA, C3, C4) and measuring fertility hormones (follicles stimulation hormone/FSH, lutenising hormone/LH) levels with histopathological examinations of female albino swiss mice ovaries in comparison with control (normal saline). A clear effect in increasing mitotic activity was reveled for both doses in comparison with control. Results also showed a significant increase in the value of the all immunological parameters at both doses in comparison with control. Also obvious rais
... Show MoreThe ligand [Potassium (E)-(4-(((2-((1-(3-aminophenyl) ethylidene) amino)-4-oxo-1, 4-dihydropteridin-6-yl) methyl) amino) benzoyl)-L-glutamate] was prepared from the condensation reaction of folic acid with (3-aminoacetophenone) through Schiff reaction to give a new Schiff base ligand [H2L]. The ligand [H2L] was characterized by elemental analysis CHN, atomic absorption (AA),(FT-IR),(UV-Vis), TLC, ES mass (for spectroscopes), molar conductance, and melting point. The new Schiff base ligand [H2L], reacts with Mn (II), Co (II), Ni (II), Cu (II), Cr (III) and Cd (II) metal ions and (2-aminophenol),(metal: derivative ligand: 2-aminophenol) to give a series of new mixed complexes in the general formula:-K3 [M2 (HL)(HA) 2],(where M= Mn (II) and Cd
... Show MoreBackground: Prolonged use of low-dose estrogen ''20 micrograms or less" Combined oral contraceptive pill (that have estrogen and progesterone steroid hormone) had an effect on bone turnover .Bone mineral density is used in clinical medicine as an indirect indicator of osteoporosis and fracture risk. The aim of the study: The aim of this study was to investigate the effect of low dose oral contraceptive pill on the cortical thickness (in millimeter) and bone mineral density at the mandibular cortex of mental and gonial regions in Hounsfield unit(HU) using spiral computed tomography. Material and method: This prospective study was conducted on computed tomographic image of 100 women aged between (20-40) years .The collected sample includes
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show More