Preferred Language
Articles
/
bBgPZZUBVTCNdQwCai3Y
Evaluation of Implant Stability Following Sinus Augmentation Utilizing Bovine Bone Mixed with Platelet-Rich Fibrin
...Show More Authors

Background: Lateral sinus augmentation and simultaneous insertion of dental implants is a highlypredictable procedure and associated with high rate of implants success.Aims: To evaluate implant stability changes following maxillary sinus augmentation utilizing deproteinizedbovine bone alone or mixed with platelet-rich fibrin.Materials and Methods: A total of 34 lateral sinus augmentation procedures were performed and 50 dentalimplants simultaneously installed. The lateral sinus augmentation cases were allocated randomly into 3groups: Group A comprised 13 procedures and 21 dental implants utilizing solely deproteinized bovine bone.Group B involved 10 cases and 16 dental implants using deproteinized bovine bone mixed with leukocyteand platelet-rich fibrin. Group C included 11 operations and 13 dental implants employing deproteinizedbovine bone mixed with advanced platelet-rich fibrin. Resonance frequency analysis test was performedimmediately after implant installation and 24 weeks postoperatively for the measurement of the implantstability.Results: Implant stability quotient values increased significantly for all study groups 24 weeks after dentalimplants installation (P= 0.001). The implant stability quotient at T1 (day of implant installation) was 56.93±12.01 for group A, 58.34 ±12.82 for group B, and 61.35 ±8.47 for group C. The implant stability quotientat T2 (24 weeks after implant insertion) was 69.17 ±5.10, 69.43 ±5.32, and 68.50 ±7.44, respectively.Conclusion: The addition of leukocyte and platelet-rich fibrin or advanced platelet-rich fibrin to the bovinebone for sinus floor augmentation did not increased the implant stability quotient value in comparison to thebovine bone alone.

Crossref
View Publication
Publication Date
Fri Jan 01 2016
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Implementation And Evaluation Of Apm 2.6 - Controlled Quadcopter With Aerial Imagery As A Case Study
...Show More Authors

Scopus (1)
Scopus
Publication Date
Thu May 05 2016
Journal Name
International Journal Of Science And Research (ijsr)
Mixed-1,10-phenanthroline with Mn(II), Cu(II),Co(II), Hg(II) and Ni(II) complexes Synthesis, Antimicrobial Activity and Spectroscopic Characterization of Binuclear Schiff Base
...Show More Authors

The M(II) complexes [M2 (phen)2 (L)(H2O)2Cl2 ] in (2:1:2 (M:L:phen) molar ratio, (where M(II) =Mn(II), Co(II), Cu(II), Ni(II) and Hg(II), phen = 1,10-phenanthroline; L = 2,2'-(1Z,1'Z)-(biphenyl-4,4'-diylbis(azan-1-yl-1-ylidene))bis(methan-1-yl-1- ylidene)diphenol] were synthesized. The mixed complexes have been prepared and characterized using 1H and13C NMR, UV/Visible, FTIR spectra methods and elemental microanalysis, as well as magnetic susceptibility and conductivity measurements. The metal complexes were tested in vitro against three types of pathogenic bacteria microorganisms: Staphylococcus aurous, Escherichia coli, Bacillussubtilis and Pseudomonasaeroginosa to assess their antimicrobial properties. From this study shows that all the

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of aqueous and alcoholic extracts of Mushroom Calvatia craniiformis in bone marrow and interferon Gamma in mice
...Show More Authors

This research was designed to study the effect of water and alcoholic crude extracts of Calvatia craniiformis in vitro and in vivo On the other hand this study tested the toxic effect of both extracts in normal laboratory mice. The results showed that water and alcoholic extracts relatively have an acute toxic effect in mice in respect to LD50 (85 mg/kg, and 177mg/kg respectively). However the chronic toxicity of water extract at three different concentration (50, 75, 100 mg/kg) and alcoholic extract at concentrations of (100, 150, 200 mg/kg) was investigated in normal mice by (I.P) administration for 30 days alternatively and one drag in 48 hours . The results indicated significant effect (P ? 0.01) increasing in (MI) and (BI) of bone mar

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Huazhong University Of Science And Technology [medical Sciences]
New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
A Study on the Effect of Multistage Toolpath in Fabricating a Customized Cranial Implant in Incremental Sheet Metal Forming
...Show More Authors

Incremental sheet forming (ISF) process offers a high degree of flexibility in the manufacturing of different sheet parts, which makes it an ideal candidate for prototype parts as well as efficient at fabricating various customized products at low production costs compared to traditionally used processes. However, parts produced in this process exhibit notable geometrical inaccuracy and considerable thickness reduction. In this paper, the single point incremental sheet forming variant of the process has been implemented to manufacture a highly customized cranial implant starting from the computed tomography (CT) scan data of the patient's anatomy. A methodology, from the modeling to the realization of the implant, is presented and discus

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun Aug 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Electrophoretic Deposition of Nano Al2O3 and AgNO3 on CpTi Dental Implant (An in vitro and in vivo study)
...Show More Authors

Background: Even the wide use of dental implants, still there is a proportion of implants are failed due to infection. Much considerable attention has been paid to modify the implant surface. Coating of dental implant with a biocomposite material of suitable properties can improve osseointegration. And this is the main concern of this study. The aim of present study was to evaluate the use of a biocomposite coating of dental implant with (ceramic nano Al2O3 and metalic AgNo3) on the bond strength at bone – implant interface and tissue reaction. Materials and methods: A total number of forty-eight screws, CpTi dental implant used in this study. Half of these screws were coated with a biocomposite material of nano (Al2O3and AgNo3), thi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition. Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray

... Show More
Crossref (10)
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition.

Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray dif

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Thu Nov 07 2024
Journal Name
Journal Of Thermal Analysis And Calorimetry
Performance improvement of phase change material (PCM)-based shell-and-tube-type latent heat energy storage system utilizing curved fins
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Nov 30 2024
Journal Name
Iraqi Journal Of Science
Utilizing the Gravity Method to Detect the Potential Effect of the Salt Dome in the Nahr Omar Oilfield, Southern Iraq
...Show More Authors

Geophysics is one of the branches of Earth sciences and deals with studying the Earth's interior by studying the variation of physical properties within rock layers. Applied geophysics depends on procedures that involve the measurements of potential fields, such as the gravitational method. One of the significant oil fields in southern Iraq is represented by the Nahr Omar structure. A power spectrum analysis (SPA) technique was used to collect gravity data within the chosen oil field area in order to confirm the salt dome in the subsurface layers. The analysis of SPA resulted from six surfaces representing the gravity variation values of the depths (m)14300, 3780, 3290, 2170, 810, and 93.5. Gravity surfaces have been converted to de

... Show More
View Publication Preview PDF
Scopus Crossref