Background: Lateral sinus augmentation and simultaneous insertion of dental implants is a highlypredictable procedure and associated with high rate of implants success.Aims: To evaluate implant stability changes following maxillary sinus augmentation utilizing deproteinizedbovine bone alone or mixed with platelet-rich fibrin.Materials and Methods: A total of 34 lateral sinus augmentation procedures were performed and 50 dentalimplants simultaneously installed. The lateral sinus augmentation cases were allocated randomly into 3groups: Group A comprised 13 procedures and 21 dental implants utilizing solely deproteinized bovine bone.Group B involved 10 cases and 16 dental implants using deproteinized bovine bone mixed with leukocyteand platelet-rich fibrin. Group C included 11 operations and 13 dental implants employing deproteinizedbovine bone mixed with advanced platelet-rich fibrin. Resonance frequency analysis test was performedimmediately after implant installation and 24 weeks postoperatively for the measurement of the implantstability.Results: Implant stability quotient values increased significantly for all study groups 24 weeks after dentalimplants installation (P= 0.001). The implant stability quotient at T1 (day of implant installation) was 56.93±12.01 for group A, 58.34 ±12.82 for group B, and 61.35 ±8.47 for group C. The implant stability quotientat T2 (24 weeks after implant insertion) was 69.17 ±5.10, 69.43 ±5.32, and 68.50 ±7.44, respectively.Conclusion: The addition of leukocyte and platelet-rich fibrin or advanced platelet-rich fibrin to the bovinebone for sinus floor augmentation did not increased the implant stability quotient value in comparison to thebovine bone alone.
The aim of this study was to evaluate the effects of local application of bisphosphonate gel and recombinant human bone morphogenic protein 2 gel, on titanium dental implant stability and marginal bone level. Twenty-seven patients with upper and lower missing posterior tooth/teeth were included in the study with a total of 71 implants that were used for rehabilitation. The implants were randomly divided into 4 groups: 3 study groups and 1 control. Group1; local application of bisphosphonate gel, group 2; local application of recombinant human bone morphogenic protein 2 gel, group 3; local application of a mixed formula of both gels. The gel application was immediately preimplant insertion, group 4; implant insertion without application of a
... Show MoreBackground: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16
... Show MoreBackground: Anterior disc displacement with reduction (ADDWR) is the most common form of the internal derangement (ID) of temporomandibular joint (TMJ). It is a painful progressive dysfunction and clinically characterized by reciprocal clicking due to shift in the disc anteriorly in relation to the condyle and fossa during mandible elevation. Minimally invasive therapy such as intra-articular injection of platelet-rich plasma (PRP) has been used. PRP is a natural autologous product with a high platelet concentration obtained by centrifugation process to enhance tissue healing through several growth factors (GFs), which are released after endogenous activation. The aim of this study is to assess this technique which is increasingly used toda
... Show MoreBackground: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received
... Show MoreBackground: Interleukin-6 (IL-6) is a cytokine that has several functions, including stimulating growth and inhibiting cell death. It has the potential to operate as a biomarker for the accurate prediction of disease severity and activity, platelets-rich plasma was used in the treatment of oral lichen planus and can change the salivary IL-6 level.
Objectives: To study the clinical outcome of intralesional platelets-rich plasma in patients with oral lichen planus and to measure salivary IL-6 levels before and after the treatment with platelets-rich plasma were the aims of this study.
Subjects and Methods: In this clinical trial, for each patient a standardi
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show More