Background: Lateral sinus augmentation and simultaneous insertion of dental implants is a highlypredictable procedure and associated with high rate of implants success.Aims: To evaluate implant stability changes following maxillary sinus augmentation utilizing deproteinizedbovine bone alone or mixed with platelet-rich fibrin.Materials and Methods: A total of 34 lateral sinus augmentation procedures were performed and 50 dentalimplants simultaneously installed. The lateral sinus augmentation cases were allocated randomly into 3groups: Group A comprised 13 procedures and 21 dental implants utilizing solely deproteinized bovine bone.Group B involved 10 cases and 16 dental implants using deproteinized bovine bone mixed with leukocyteand platelet-rich fibrin. Group C included 11 operations and 13 dental implants employing deproteinizedbovine bone mixed with advanced platelet-rich fibrin. Resonance frequency analysis test was performedimmediately after implant installation and 24 weeks postoperatively for the measurement of the implantstability.Results: Implant stability quotient values increased significantly for all study groups 24 weeks after dentalimplants installation (P= 0.001). The implant stability quotient at T1 (day of implant installation) was 56.93±12.01 for group A, 58.34 ±12.82 for group B, and 61.35 ±8.47 for group C. The implant stability quotientat T2 (24 weeks after implant insertion) was 69.17 ±5.10, 69.43 ±5.32, and 68.50 ±7.44, respectively.Conclusion: The addition of leukocyte and platelet-rich fibrin or advanced platelet-rich fibrin to the bovinebone for sinus floor augmentation did not increased the implant stability quotient value in comparison to thebovine bone alone.
An abstract is a brief summary of a research article, thesis, Schiff base ligand (L) was prepared by the reaction of 4-aminantipyrine with o-phenylenediamine, the prepared ligand characterized by Micro elemental Analysis, FT. IR, UV-Vis, and 1H,13C-NMR spectroscopy.complexes of Mn(II), Co(II), Ni(II), Cu(II) and Hg(II) with Schiff base and 1,10-phenanthroline (Phen) have been investigated in aqueous ethanol with (1:1:1) (M:L:Phen). The prepared complexes were characterized using flame atomic absorption, (C. H. N) Analysis, FT. IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. From the obtained data the octahedral structure was suggested for all complexes. The biological screening effects o
... Show MoreIn the present article, mixed ligand metal (II) complexes have been synthesized with Schiff base (1E, 5Z, 6E)-1,7 bis (4-hydroxy-3- methoxyphenyl)-5-(3-hydroxyphenyl) imino) hepta-1,6-dien-3-one derived from Curcumin and 3-aminophenol as primary ligand and L-dopa as a secondary ligand. The Schiff base act as bidentate and arrange to the metals through the azomethine (C=N) nitrogen and (C=O) oxygen atom. The mode of bonding of the Schiff base has been affirmed on the infrared by the UV-Visible, 1H, and 13C NMR spectroscopic techniques. The magnetic susceptibility and the UV-Vis data of the complexes propose octahedral geometry around the central metal ion. The information appears that the complexes have the structure of [L-M-(L-dopa)] system
... Show MoreThe ground state proton, neutron, and matter density distributions and corresponding root-mean-square (rms) of P19PC exotic nucleus are studied in terms of two-frequency shell model (TFSM) approach. The single-particle wave functions of harmonic-oscillator (HO) potential are used with two different oscillator parameters bRcoreR and bRhaloR. According to this model, the core nucleons of P18PC nucleus are assumed to move in the model space of spsdpf. The shell model calculations are carried out for core nucleons with w)20(+ truncations using the realistic WBPinteraction. The outer (halo) neutron in P19PC is assumed to move in the pure 2sR1/2R-orbit. The halo structure in P19PC is confirmed with 2sR1/2R-dominant configuration.Elastic electr
... Show MoreBackground: Bone cutter is widely used in the
Middle east area to cut the prepuce during circumcision.
Results :One hundred twenty one male neonates
were included in this study.The mean operative
time (MOT) was 6 minutes, mean time of
healing (MTH) was 5 days, 7 cases (5.9%)
developed early & late complications, 2 (1.7%)
had bleeding, 3 (2.5%) developed infection, 2
(1.7%) developed late complications in the form
of meatal stenosis.
Settings:Al-Yarmouk Teaching Hospital and a
private surgical clinic.
Aim of the study: To assess the safety of
circumcision using bone cutter.
Methods: Over 6 years period from Jan. 2000
till Dec. 2005, one hundred twenty one male
neonates were circumci
(1) Background: Sleeping disorders are frequently reported following traumatic brain injury (TBI). Different forms of sleeping disorders have been reported, such as sleepiness, insomnia, changes in sleeping latency, and others. (2) Methods: A case-control study with 62 patients who were victims of mild or moderate TBI with previous admissions to Iraqi tertiary neurosurgical centers were enrolled as the first group, and 158 patients with no history of trauma were considered as the control. All were 18 years of age or older, and the severity of the trauma and sleep disorders was assessed. The Pittsburgh sleep quality index was used to assess sleep disorders with average need for sleep per day and average sleep latency were assessed in
... Show MoreSince Internet Protocol version 6 is a new technology, insecure network configurations are inevitable. The researchers contributed a lot to spreading knowledge about IPv6 vulnerabilities and how to address them over the past two decades. In this study, a systematic literature review is conducted to analyze research progress in IPv6 security field following the Preferred Reporting Items for the Systematics Review and Meta-Analysis (PRISMA) method. A total of 427 studies have been reviewed from two databases, IEEE and Scopus. To fulfil the review goal, several key data elements were extracted from each study and two kinds of analysis were administered: descriptive analysis and literature classification. The results show positive signs of t
... Show MoreBack ground : The transforming growth factor beta (TGFB) signaling pathway is involved in many cellular processes in both the adult organism and the developing embryo including cell growth, cell differentiation, apoptosis. The interaction between implant material and surrounding tissues is believed to play a fundamental role in implant success and illustrates different expression of growth factors by different cells that involved in the formation of peri-implant tissue. The aim of this study was to localize expression of TGF B by newly formed bone tissue around surface-conditioned implants with placental collagen at different time intervals: 3 ,7,14,28, and 56 days . Materials and Methods: Commercially pure Titanium (CPTi) implants coated w
... Show MoreBackground: In the traditional protocol, the patient should wait after extraction up to six months to place the dental implant in healed bone, this waiting time accompanied by varying degrees of alveolar bone changes. In order to overcome these problems, immediate implant placement in the fresh extraction socket was introduced. The Aim of this study was to evaluate the outcome of the immediate implant placement utilizing Resonance Frequency Analysis (RFA) to quantify implant stability and osseointegration. Materials and Methods: A total of (23) patients participated in the study, receiving (44) implants placed in the sockets of teeth indicated for extraction. Clinical and radiographic preoperative assessment was accomplished for each patie
... Show MoreThe researcher [1-10] proposed a method for computing the numerical solution to quasi-linear parabolic p.d.e.s using a Chebyshev method. The purpose of this paper is to extend the method to problems with mixed boundary conditions. An error analysis for the linear problem is given and a global element Chebyshev method is described. A comparison of various chebyshev methods is made by applying them to two-point eigenproblems. It is shown by analysis and numerical examples that the approach used to derive the generalized Chebyshev method is comparable, in terms of the accuracy obtained, with existing Chebyshev methods.