A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of the soil, the results showed a difference in the depth of water according to the moisture depletion, which amounted to 900 mm. Season-1 treatment for 10% depletion and decreased to 10 and 16.6% when 20 and 40% of the prepared water was depleted, respectively. The intervention between drip lines and irrigation treatments led to a significant increase in grain yield when using a distance of 10 cm and irrigation when 10% of the available water was depleted. There were no significant differences in grain yield at I10 despite the difference in the distance between the drip lines. The efficiency of field and crop water use and the profitability of water outperformed I10.
Abstract
Experimental work from Magnetic Abrasive Finishing (MAF) tests was carried out design parameters (amplitude, and number of cycle which are formed the shape of electromagnetic pole), and technological parameters (current, cutting speed, working gap, and finishing time) all have an influence on the mechanical properties of the surface layer in MAF process. This research has made to study the effect of design and technological parameters on the surface roughness (Ra), micro hardness (Hv) and material removal (MR) in working zone. A set of experimental tests has been planned using response surface methodology according to Taguchi matrix (36) with three levels and six factors
... Show MoreMesoporous silica (MPS) nanoparticle was prepared as carriers for drug delivery systems by sol–gel method from sodium silicate as inexpensive precursor of silica and Cocamidopropyl betaine (CABP) as template. The silica particles were characterized by SEM, TEM, AFM, XRD, and N2adsorption–desorption isotherms. The results show that the MPS particle in the nanorange (40-80 nm ) with average diameter equal to 62.15 nm has rods particle morphology, specific surface area is 1096.122 m2/g, pore volume 0.900 cm3/g, with average pore diameter 2.902 nm, which can serve as efficient carriers for drugs. The adsorption kinetic of Ciprofloxacin (CIP) drug was studied and the data were analyzed and found to match well with
... Show MoreIn solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show MoreIn this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show MoreThe need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature
... Show MoreThe steady state performance of the counter rotating floating ring Journal bearing is analyzed with isothermal finite bearing theory. The effect of different parameters affecting the performance of the bearing (namely speed ratio, clearance ratio and radii ratio), have been investigated. The load carrying capacity of the bearing increasing with decreasing the radii ratio (R2/R1) of the ring and clearance ratio (c1/c2), in the other hand, the coefficient of friction increases with increasing the clearance and radii ratios, while decreases with incre4asing the bearing to journal speed ratio (γ). It is shown during this work that different operating conditions are greatly enhanced the performance
... Show MoreThe current research aims to identify the degree to which a sample of managers in public organizations appreciated the level of application of the service leadership style from their point of view, and its relationship to the customer satisfaction index in light of the (Covid-19) pandemic, to achieve this, the researcher followed the experimental approach by applying a questionnaire that included two axes, The first: to measure the level of service leadership according to the scale (D. Van Dierendonck and I. Nuijten, 2011), which includes (8) dimensions (empowerment, stand back, accountability, courage, forgiveness, Authenticity, humility, stewardship). The second axis: to measure the level of customer satisfaction according to (Askim, 2004
... Show More