Preferred Language
Articles
/
bBZjuosBVTCNdQwCptg7
The Effect of Dry Farming and Water Stress under Subsurface Drip Irrigation System on Water and Rice Productivity
...Show More Authors
Abstract<p>A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of the soil, the results showed a difference in the depth of water according to the moisture depletion, which amounted to 900 mm. Season-1 treatment for 10% depletion and decreased to 10 and 16.6% when 20 and 40% of the prepared water was depleted, respectively. The intervention between drip lines and irrigation treatments led to a significant increase in grain yield when using a distance of 10 cm and irrigation when 10% of the available water was depleted. There were no significant differences in grain yield at I10 despite the difference in the distance between the drip lines. The efficiency of field and crop water use and the profitability of water outperformed I10.</p>
Scopus Crossref
View Publication
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Using of Index Biological Integrity of Phytoplankton (P-IBI) in the Assessment of Water Quality in Don River Section
...Show More Authors

       The multimetric Phytoplankton Index of Biological Integrity (P-IBI) was applied throughout Rostov on Don city (Russia) on 8 Locations in Don River from April – October 2019. The P-IBI is composed from seven metrics: Species Richness Index (SRI), Density of Phytoplankton and total biomass of phytoplankton and Relative Abundance (RA) for blue-green Algae, Green Algae, Bacillariophyceae and Euglenaphyceae Algae. The average P-IBI values fell within the range of (45.09-52.4). Therefore, water throughout the entire study area was characterized by the equally "poor" quality. Negative points of anthropogenic impact detected at the stations are: Above the city of Rostov-on-Don (1 km, higher duct Aksai) was 38.57 i

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jan 06 2019
Journal Name
Arabian Journal Of Geosciences
Iron Content Variations in Sphalerite and Their Effects on Reflectance and Internal Reflections under Reflected Light
...Show More Authors

Publication Date
Sun Jul 06 2014
Journal Name
Journal Of Educational And Psychological Researches
The Intellectual Stress and Its Relationship with Personality' s Five Major Factors of Counselors
...Show More Authors

The current study aims at identifying:

1-The intellectual stress of counselors according to gender variable (male, female ).

2-The five major  factors of the  Counselor's  Personality.

3-  The relationship between intellectual stress and the five major factors of the councilors' personality and according to gender variable (male, female ).

4-The significant differences in the relationship between intellectual stress and the five major factors of the councilors' personality and according to gender variable  (male, female ).

The sample of the study includes (260) counselors (130 male

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 15 2023
Journal Name
Iraqi Journal Of Science
Poly (N, N-dimethyl aniline) Coating for Stainless Steel, Synthesis, Characterization and Corrosion Protection in Sea Water 3.5% NaCl Solution
...Show More Authors

This research involves the synthesis of conductive polymer includes: poly (N, Ndimethyl
aniline) on metal surface which is stainless steel 316 by using
electrochemical polymerization technique. Parameters of this research are voltage
rang, scan rate, number of cycles. The tests for corrosion protection of the polymer
coated and uncoated stainless steel substrate was investigated in artificial sea water
of 3.5% NaCl solution by tafel and potentiodynamic procedures. Fourier Transform
Infrared Spectroscopy (FTIR), UV-Visible absorption spectroscopy, Scanning
Electron Microscope (SEM) and Atomic Force Microscope (AFM) were used to
diagnose and describe the structure and morphology of the coating. Parameters of
corr

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Examining how PMMA and polyamide denture base materials' physical characteristics are affected by electrolyzed water used as a denture cleaner
...Show More Authors

Denture cleansing is an essential step that can stop cross‑contamination and adds to the health of the patient, denture durability, and the general quality of life. A disinfection technique must be practical and devoid of damaging effects on the material's properties used to construct the denture base. The main aim of this study is to evaluate the effect of three concentrations of electrolyzed water denture cleanser on heat cure acrylic and polyamide after immersion in electrolyzed water. The evaluation is based on their efficacy on surface hardness, wettability, and color stability compared with one submerged in distilled water as a control group. The method consists of eighty samples of heat-cured acrylic and polyamide material.

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Mathematical Modelling for Peristaltic Flow of Sutterby Fluid Through Tube under the Effect of Endoscope
...Show More Authors

     In this work, the mathematical modelling of peristaltic transport for incompressible Sutterby fluid through the cavity between coaxial tubes where the inner tube is fixed and the outer tube has sinusoidal rhythmic fluctuations along the channel’s walls is presented. Under the assumption of long wavelength and the low Reynolds number, the governing equations (motion, temperature, and concentration) are illustrated in cylindrical coordinates. The analytical solution for the temperature and concentration of the fluid flow is obtained using Mathematica 11.3, whereas the perturbation technique is employed to find the closed form of the velocity profile. The variation of the axial velocity, stream function, temperat

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon May 27 2024
Journal Name
Pakistan Journal Of Criminology
The Liability of Maritime Carrier under the Iraqi Transport Law and International Conventions
...Show More Authors

Everywhere carriers incur a measure of liability for the safety of the goods. Carriers are liable for any damage or for the loss of the goods that are in their possession as carriers unless they prove that the damage or loss is attributable to certain excepted causes. Damaged and lost items can unfortunately be a common problem when shipping freight. Legal responsibilities arise due to loss or damage during transit while cargo is in their care. This study intends to investigate the nature of the liability of the maritime carrier when this liability is realized, and the extent to which it can be paid or disposed of given the risks realized from the transportation process, which may result in damage or loss of the goods, and the damag

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jan 11 2022
Journal Name
Iraqi Journal Of Science
Removal of Some Traces Heavy Metals from Aqueous Solutions by Water Hyacinth Leaves Powder
...Show More Authors

The pollution of aquatic ecosystems with toxic heavy metals is representing a major environmental issue, as a result of releasing these metals to ecological ambient without treatment, leading to their persistence and non-biodegradation in the environment. Various traditional methods are utilized as an attempt to remove heavy metals from waste water but still without making any actual progress. This study hypothesizes that Eichhornia crassipes (water hyacinth) dried leaves powder is potential in removing some of these heavy metals (HM), including lead, copper, cadmium and chrome from aqueous solutions via biosorption influenced by some variable experimental factors. This aim was approached by using two different experimental conditions: (

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 31 2022
Journal Name
Iraqi Journal Of Science
Evaluation of Water Quality for Greater Zab River by Principal Component Analysis/ Factor Analysis
...Show More Authors

This study was conducted to determining the variable effects on water quality of Greater Zab River in Erbil province, Iraq, using multivariate statistical analysis. Seventeen variables were monitored in four sampling sites during one year (from May 2012 to April 2013). The dataset were treated using principal component analysis (PCA)/ factor analysis (FA), cluster analysis (CA) to the most important factors affecting water quality, sources of pollution and suitability of water for drinking consumption and irrigation. Six factors were identified as responsible for the data structure explaining 73.5% of the total variance in the dataset and are conditionally named, hydrochemical from weathering, mineral salts and domestic wastes. CA showed

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water

... Show More
View Publication Preview PDF