Preferred Language
Articles
/
b4aBrYYBIXToZYALJqO9
Behavior of One-Way Reinforced Concrete Slabs with Polystyrene Embedded Arched Blocks
...Show More Authors

This study presents experimental and numerical investigations on seven one-way, reinforced concrete (RC) slabs with a new technique of slab weight reduction using polystyrene-embedded arched blocks (PEABs). All slabs had the same dimensions, steel reinforcement, and concrete compressive strength. One of these slabs was a solid slab, which was taken as a control slab, while the other six slabs were cast with PEABs. The main variables were the ratio of the length of the PEABs to the length of the slab (lp/L) and the ratio of the height of the PEABs to the total slab depth (hP/H). The minimum decrease in the ultimate load capacity was about 6% with a minimum reduction in the slab weight of 15%. In contrast, the maximum decrease in the ultimate load capacity was about 24% with a maximum reduction in the slab weight of 40%. Moreover, the mode of failure changed from flexure to shear failure, especially for those slabs with an lP/L ratio equal to one. The geometric and material non-linearity was adopted in the proposed finite element (FE) model to simulate the slabs with PEABs using Abaqus software. Good agreement was obtained between the developed FE and experimental results.

Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
The Behavior of Scouring Around Multiple Bridge Piers Having Different Shapes
...Show More Authors
Abstract<p>In this research, a numerical simulation was conducted to study the behavior of the scouring pattern and the effect of spacing between bridge piers at specified hydraulic conditions such as velocity, depth of flow, and the sediment effective diameter. Moreover, the cross-section shape of piers and their effect on the scouring depth around bridge piers was studied, using Computational Fluid Dynamics (CFD), ANSYS (Fluent) software. A comparison of the simulation results obtained with previous laboratory investigations was done to verify the validity of the numerical model. Generally, the scour pattern using the CFD software gave good agreement with the experimental study. A reversed pro</p> ... Show More
View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today
Behavior of RC columns strengthened by combined (CFRP and steel jacket)
...Show More Authors

Scopus (11)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun May 06 2012
Journal Name
Al-rafidain Journal For Sport Sciences
Analysis study (Guessing and techntion of self consistent degree) in choosing the perfect way from different method for two kinds rotation (orthogonal & oblique) in factore
...Show More Authors

The factorial analysis method consider a advanced statistical way concern in different ways like physical education field and the purpose to analyze the results that we want to test it or measure or for knowing the dimensions of some correlations between common variables that formed the phenomenon in less number of factors that effect on explanation , so we must depend use the self consistent that achieved for reaching that basic request. The goal of this search that depending on techntion of self consistent degree guessing for choosing perfect way from different methods for (orthogonal & oblique) kinds in physical education factor studies and we select some of references for ( master & doctoral) and also the scientific magazine and confere

... Show More
Preview PDF
Publication Date
Tue Sep 19 2017
Journal Name
International Journal Of Science And Research
Volumetric Change of Concrete Containing Water Absorption Polymer Balls
...Show More Authors

Polymers have the ability to extract water after they have been added to the mortar or concrete mixture. They provide the absorbed water during hydration functioning as internal water source. Absorption polymers can absorb up to hundred times of their own weight of pure water.This research deals with the use of water absorption polymer balls in concrete and study the volumetric change of these mixes and compared the results with reference mix (without polymers). Samples were cured both in air and in water for the mixes to compare results which show that samples in air behave for expansion while sample in water acted for shrinkage.

Publication Date
Thu Aug 26 2021
Journal Name
International Journal Of Applied Mechanics And Engineering
Probabilistic Mesoscale Analysis of Concrete Beams Subjected to Flexure
...Show More Authors
Abstract<p>In this paper, the probabilistic behavior of plain concrete beams subjected to flexure is studied using a continuous mesoscale model. The model is two-dimensional where aggregate and mortar are treated as separate constituents having their own characteristic properties. The aggregate is represented as ellipses and generated under prescribed grading curves. Ellipses are randomly placed so it requires probabilistic analysis for model using the Monte Carlo simulation with 20 realizations to represent geometry uncertainty. The nonlinear behavior is simulated with an isotropic damage model for the mortar, while the aggregate is assumed to be elastic. The isotropic damage model softening be</p> ... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jul 01 2016
Journal Name
International Journal Of Advanced Research
Attenuation Coefficient of Reactive Powder Concrete Using Different Energies.
...Show More Authors

Linear and mass attenuation coefficient of reactive powder concrete (RPC) sample ( of compressive strength equal to 70 Mpa) using beta particles and gamma ray with different energies have been calculated as a function of the absorber thickness and energy. The attenuation coefficient were obtained using NaI(Tl) energy selective scintillation counter with 90Sr/90Y beta source having an energy rang from (0.546-2.274) MeV and gamma ray energies (0.569, 0.662, 1.063, 1.17 and 1.33) MeV . The attenuation coefficient usually depends upon the energy of radiations and nature of the material. The result represented in graphical forms. Exponential decay was observed. It is found that the capability of reactive powder concrete to absorber beta particle

... Show More
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
The influence of incorporating recycled brick on concrete properties
...Show More Authors
Abstract<p>One of the major problems in modern construction is the accumulation of construction and demolition waste; this study thus examines the consumption of waste brick in concrete based on the use of blended nano brick powder as replacement for cement and as a fine aggregate. Seven concrete mixes were developed according to ACI 211.1 using recycled waste brick. Nano powder brick at 0, 5, and 10% was used as a replacement by cement weight, with other mixes featuring 10, 20, and 30% partial replacement by volume of river sand with brick. The experimental results for replacement of cement with nano brick powder showed an enhancement in mechanical properties (compressive, flexural, and tensile strength) at 7,</p> ... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Sun Jul 31 2016
Journal Name
International Journal Of Advanced Research
Attenuation Coefficient of Reactive Powder Concrete Using Different Energies.
...Show More Authors

View Publication
Crossref (6)
Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Engineering
Serviceability Performance of Externally Prestressed steel-Concrete Composite Girders
...Show More Authors

Publication Date
Sat Jun 01 2013
Journal Name
Engineering And Technology Journal
Effect of External Sulfate Attack on Self Compacted Concrete
...Show More Authors

Self-compacting concrete (SCC) is an innovative concrete that does not require vibration for placing and compaction. It is able to flow under its own weight, completely filling formwork and achieving full compaction, even in the presence of congested reinforcement. The effect of external sulfate attack was studied-Es (very sever exposure SO4>10000ppm) according to ACI 318-11. The mix design method of SCC used is according to EFNARC 2002, and then must satisfy the criteria of filling ability, passing ability and segregation resistance. The experimental program focuses to study two different chemical composition of sulfate resistance Portland cement with different percentage of silica fume replacement by weight of cement and W/cm (0.3 and 0.3

... Show More
Preview PDF