Preferred Language
Articles
/
b4a4U4YBIXToZYALAoKg
Thermal performance of a flat-plate solar collector using aqueous colloidal dispersions of multi-walled carbon nanotubes with different outside diameters
...Show More Authors

The thermal performance of a flat-plate solar collector (FPSC) using novel heat transfer fluids of aqueous colloidal dispersions of covalently functionalized multi-walled carbon nanotubes with β-Alanine (Ala-MWCNTs) has been studied. Multi-walled carbon nanotubes (MWCNTs) with outside diameters of (< 8 nm) and (20–30 nm) having specific surface areas (SSAs) of (500 m2/g) and (110 m2/g), respectively, were utilized. For each Ala-MWCNTs, waterbased nanofluids were synthesized using weight concentrations of 0.025%, 0.05%, 0.075%, and 0.1%. A MATLAB code was built and a test rig was designed and developed. Heat flux intensities of 600, 800, and 1000 W/m2; mass flow rates of 0.6, 1.0, and 1.4 kg/min; and inlet fluid temperatures of 30, 40, and 50°C were used to perform the test runs. Using water and nanofluids, the efficiency of the FPSC was found to increase with the increase in heat flux intensity and flow rate, and decrease with the increase in inlet fluid temperature. When applying nanofluids in the FPSC and as weight concentration and SSA increased, a reduction in the values of absorber plate temperature (AP) and tube wall temperature (TW) was observed down to 2.86% and 3.03%, respectively, while the FPSC’s efficiency increased up to 9.55% for 0.1-wt% Ala-MWCNTs < 8 nm at 1.4 kg/min, compared with water. Good agreement was obtained between the experimental values and MATLAB code predictions for AP, TW, and efficiency with maximum differences of 3.02%, 3.19%, and 3.26% for water, and 4.24%, 3.94%, and 12.64% for nanofluids, respectively. Consequently, the MATLAB code was judged suitable for modeling the nanofluid-based FPSC with suitable precision. It was proved that the positive effects of using nanofluids in the FPSC were higher their negative effects on pressure drop because all the calculated values of performance index (PI) were more than 1. As weight concentration and SSA increased, PI increased up to 1.095 for 0.1-wt% Ala-MWCNTs < 8 nm. Therefore, it was concluded that the nanofluids considered in this research can usefully be employed as working fluids in FPSCs for improved thermal performance, and the 0.1-wt% water-based Ala-MWCNTs < 8 nm nanofluid was fairly the distinguished one.

Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
The use of ionic pumping method for improving the performance of vacuum micro-electronic valves: The use of ionic pumping method for improving the performance of vacuum micro-electronic valves
...Show More Authors

Abstract
The use of electronic valves is commonly available. yet, the most
common is the techniques of communications as prod casting transmitter that
are used by these valves in addition to their use in communication tools as far
distance telephone, electronic measuring techniques , and others.
In this study, an attempt is endeavored for improving the efficiency of the
vacuum micro- valves(GI-19b) through activating their internal surfaces by the
use of ionic pumping which is used for treating valves which are out of order
(because of sedimentation some materials and oxide on its poles). The
existence of these materials and oxide increase the sum of current leakage
moving in between. The use of ionic pumpin

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 01 2019
Journal Name
Environmental Technology & Innovation
Cadmium removal using a spiral-wound woven wire meshes packed bed rotating cylinder electrode
...Show More Authors

The effect of electrolysis operating parameters on the removal efficiency of cadmium from a simulated wastewater was studied by adopting response surface methodology combined with Box–Behnken Design. As a new electrode design, spiral-wound woven wire mesh rotating cylinder electrode was used for cadmium removal. Current (240–400 mA), rotation speed (200–1000 rpm), initial cadmium concentration (200–600ppm), and cathode mesh number (30–60) were chosen as independent variables while the removal efficiency of cadmium was considered as a response function. The results revealed that the rotation speed has the major effect on the removal efficiency of cadmium. Regression analysis showed good fit of the experimental data to the second-or

... Show More
View Publication Preview PDF
Scopus (27)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Influence of Varying Temperature and Concentration on Magnetohydrodynamics Peristaltic Transport for Jeffrey Fluid with a Nanoparticles Phenomenon through a Rectangular Porous Duct
...Show More Authors

A mathematical model constructed to study the combined effects of the concentration and the thermodiffusion on the nanoparticles of a Jeffrey fluid with a magnetic field effect the process of containing waves in a three-dimensional rectangular porous medium canal. Using the HPM to solve the nonlinear and coupled partial differential equations. Numerical results were obtained for temperature distribution, nanoparticles concentration, velocity, pressure rise, pressure gradient, friction force and stream function. Through the graphs, it was found that the velocity of fluid rises with the increase of a mean rate of volume flow and a magnetic parameter, while the velocity goes down with the increasing a Darcy number and lateral walls. Also, t

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Fri Jan 19 2024
Journal Name
Research Journal Of Pharmacy And Technology
Serum Levels of Fetuin-A, Ischemia-modified Albumin (IMA), and Ferritin in Hospitalized patients with severe COVID-19. A Case-control Study
...Show More Authors

Objective: To measure the serum levels of Fetuin-A, ischemia-modified albumin (IMA), and ferritin in hospitalized patients with severe COVID-19in Baghdad, Iraq. Moreover, to determine these biomarkers' cut-off valuesthat differentiate between severely ill patients and control subjects. Methods: This case-control study was done from 15 September to the end of December 2021 and involved a review of the files and collectionof blood samples from patients (n=45, group1) hospitalized in COVID-19 treatment centersbecause of severe symptoms compared tohealthy subjects as controls (n=44, group2). Results: Fetuin-A serum levels were not statistically different between patients and controls. In contrast, IMA and ferritin levels were significan

... Show More
Scopus Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Pharmaceutical Sciences
Development and Evaluation of Biodegradable Particles Coloaded With Antigen and the Toll-Like Receptor Agonist, Pentaerythritol Lipid A, as a Cancer Vaccine
...Show More Authors

View Publication
Scopus (21)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 04 2013
Journal Name
Jordan Journal Of Biological Sciences
Bacteriocin Typing of Staphylococcus aureus Isolated from Different Sources in Ibb City, Yemen
...Show More Authors

Abstract A total of 207 specimens were collected from different sources including patients, health care staff and hospital environment in Ibb city, Yemen. The study used the bacteriocin produced from active producer strains in typing of Staphylococcus aureus. Depending on the morphological, cultural and biochemical characteristics, 54 (26.09%) isolates of Staphylococcus aureus were identified. An antibiotic sensitivity test was done for the bacterial isolates, and the results showed that there were multiple resistant antibiotics. The Staphylococcin production of these isolates has been detected by using wells assay. Fifty one isolates were Staphylococcin producer. Four isolates (staph19, staph25, staph28 and staph43) were chosen as go

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Wed Oct 08 2008
Journal Name
Journal Of Kerbala University
Viscosity and Volumetric studies of some amino acids in solutions at different temperatures.
...Show More Authors

Publication Date
Thu Jan 15 2009
Journal Name
Journal Of Kerbala University
Viscosity and Volumetric studies of some amino acids in solutions at different temperatures
...Show More Authors

Densities ρ and viscosities η for several concentrations of amino acids (Serine, Cysteine and Threonine) at different temperatures (298.15, 303.15 and 308.15K) have been measured. On the basis of these data, the apparent molal volumes v , partial molal volumes at infinite dilution v , slope Sv , Gibbs free energy of activation for viscous flow of solution ∆G1,2 and Jones – Dole Bcoefficients were calculated the nature of solute-solvent and solute-solute interactions have been discussed in terms of the values of v , v , Sv and B-coefficents

Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and in Vitro Evaluation for Different Types of Ondansetron Hydrochloride Transdermal Patches
...Show More Authors

This research aims to develop transdermal patches of Ondansetron hydrochloride (OSH) with different types of polymers, ethyl cellulose and, polyvinyl pyrrolidone k30 in a ratio (3:0.5,3:1,3:2,2:1,1:1) with propylene glycol 20%w/w as a plasticizer. Prepared transdermal patches were evaluated for physical properties. The compatibility between the drug and excipients was studied by Differential scanning calorimetry (DSC), where there is no interaction between the drug and polymers. From the statistical study, there is a statistical difference between all the prepared formulations p<0.05. In-vitro Release study of transdermal patches was performed by using a paddle over the disc. The release profile of OSH follow

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref