Abstract : Silicone elastomer is widely used as the material of choice for fabricating maxillofacial prosthesis. However, silicone properties are far from ideal; low tear strength, low tensile strength and insufficient elasticity are the most undesirable properties. The purpose of this study was to evaluate the effect of addition of nano SiO2filler on tear strength, tensile strength, elongation at break, hardness and color of Cosmesil M-511 HTV maxillofacial silicone elastomer. Nano SiO2was added to the silicone base in concentrations of 4%, 5% and 6% by weight. Silicone with 0% nano filler served as a control. Tear test was done according to ISO 34-1. Tensile and elongation test was done according to ISO 37. Shore A hardness test was done according to ISO 7619. Visual color measurement test was done according to ASTM D1535. Scanning electron microscope was used to assess the efficiency of dispersing method. FTIR test was conducted to evaluate the interaction of nano SiO2with the silicone. Statistical analysis was done using one-way ANOVA and Fisher’s LSD test. SEM showed well dispersion of nano filler within the silicone matrix. FTIR indicated that nano SiO2interacted with the PDMS through its surface hydroxyl group. All nano SiO2concentration groups showed a highly significant increase in tear strength, tensile strength and elongation at break compared to the control group. The 5% group showed the highest mean values among other groups. Shore A hardness showed a highly significant increase with all nano SiO2concentrations with the increase being directly proportional to filler concentration increase. Spectrophotometer results showed a highly significant decrease in translucency of the material with all nano filler concentrations but this decrease in translucency was visually demonstrated as slight increase in color intensity. Reinforcement of M-511 silicone with 5% nano SiO2significantly improves all mechanical properties tested with a slight change of color seen visually.
A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreIntroduction: The bacteriological and histopathological study of Raoultella planticola in local rabbits is not presented in previous research. There is no specific information about studying this bacterium in local rabbits. Hypothesis: The present study was based on Bacteriological and Histopathological changes in the trachea and lung of local rabbits after Samples were collected from 50 unhealthy animals that appear to be suffering from respiratory signs. Aim: To study the bacteria that were isolated for the first time from sheep suffering from respiratory infections, and diagnose them through Vitk2. Methods: We injected them into a group of local rabbits and studied the histopathological changes in the trachea and lungs. d
... Show MoreMixed ligands reaction of [2-[(3-hydroxyphenyl)diazinyl]-1,2-benzothiazol-3(2H)-one-1,1-dioxide] (H2L, primary ligand) and bipyridyl (secondary ligand) with salts of Cr(III), Mn(II), Fe(III), Co(II) and Ni(II) was performed. A series of air-stable complexes with distinctive octahedral moieties was created by equal molar ratio (1:1:1). The formation of these compounds was verified using detecting analysis techniques incorporating mass spectra, which validated the achieved geometries. Fourier transform infrared (FTIR) analysis demonstrated how the ligands (H2L and bipyridyl) are chelated as tridentate (ONO) and bidentate (NN) groups, respectively and the coordination with the metal ions. Thermal decomposition studies using pyrolysis (
... Show MoreA simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi
... Show MoreUntil today, one of the leading predominant infections is Urinary tract infection (UTI). It exerts a huge burden on health systems worldwide each year. Treating UTIs empirically with antimicrobials improves morbidity rates. This study aims to assess the prevalence of UTI-associated bacteria in adult patients and to determine their antibiotic susceptibility profile. A retrospective study was conducted for adult outpatients who visited Al-Diwaniya tertiary hospitals from January 2020 till February 2022 to review their medical and lab records in addition to sociodemographic data. A total of 256 patients’ records were included of which 204 (79.7%) belong to females and 52 (20.3%) were males with an average age of 39.22±17.10 years. T
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreOne common heavy metal that is extremely harmful to the kidneys, reproductive system, and nervous system of humans is lead (Pb). This study aimed to investigate the effectiveness of a novel nanocomposite adsorbent, synthesised from polypyrrole, zinc oxide, and nickel (PPy/ZnO-NiO), in eliminating Pb(II) ions from a waterbased solution. This adsorbent offers excellent metal selectivity, environmental stability, ease of manufacture, and reusability. Several techniques, namely XRD, FTIR, TGA, SEM, TEM, EDX, and BET, were employed to characterize the synthesised nanocomposite adsorbent. The study examined the impact of multiple factors influencing the adsorption process, including pH, temperature, contact period, metal ion concentration, and ad
... Show MoreThe importance of this research comes from the possibility of achieving positive interaction between accounting and tax through the interest in setting accounting standards and adapting them to local tax legislation, as the adoption of the application of the international standard (IAS 12) for income taxes helps to measure and determine the base for income tax and may lead to an increase in the tax outcome. Through the reliance of enterprises on many accounting bases, and that the tax administration in Iraq depends on the element of personal judgment in determining the tax base, which leads to lack of objectivity in determining the tax outcome, as the impact of the accounting standard (IAS 12) on the tax base and tax outcome is one of th
... Show More