Preferred Language
Articles
/
axaTE4cBVTCNdQwCLTRl
MATHEMATICAL SIMULATION OF UNSTEADY FLOW THROUGH HOLLOW FIBER MEMBRANE
...Show More Authors

Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of HF and HCl Chemical Laser Parameters by using Mathematical Model
...Show More Authors

A simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Educational And Psychological Researches
The level of school students understand the basic mathematical concepts Engineering Preparation
...Show More Authors

This study aims at recognizing the levels of comprehension of the students of basic schools to the concepts of mathematical geometric and discovering the existing of the differences among students in the level of understanding of the concepts of mathematical geometrical which is due to the change of gender.

The sample of the study is the students of Basic schools, eight level in the basic school of Erbil city, particularly 7-8-and 9 levels in the academic year 2013-2014. The sample consists of 444 students in both genders238 males and 206 females.

The tool of the study is test sheet included 20 items of multiple choice.  The items are valid since are given to a jury of expert

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
SECURED SMART CARD SIMULATION
...Show More Authors

Different methods of encryption that are widely used in smart card have been presented. Because of the usefulness and widespread application of Food Ration Card throughout our country, three models of designing and simulations are developed. A comparison between the different models is done. The first model is the Food Ration Card without using any security method. The second model is the Food Ration Card with using an AES algorithm as a security method. The third model is the Food Ration Card with using RSA method. All models are implemented and simulated using  BasicCard Development kit Environment. For the first model, a Compact BasicCard version ZC1.1 is used. While for the second and third models, a Professional BasicCard versi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Kinetic Model for Solute Diffusion in Liquid Membrane Systems
...Show More Authors

In this study, a mathematical model for the kinetics of solute transport in liquid membrane systems (LMSs) has been formulated. This model merged the mechanisms of consecutive and reversible processes with a “semi-derived” diffusion expression, resulting in equations that describe solute concentrations in the three sections (donor, acceptor and membrane). These equations have been refined into linear forms, which are satisfying in the special conditions for simplification obtaining the important kinetic constants of the process experimentally.

View Publication Preview PDF
Crossref
Publication Date
Wed Sep 09 2020
Journal Name
Optics Express
Monolithically integrated membrane-in-the-middle cavity optomechanical systems
...Show More Authors

We describe curved-mirror Fabry-Perot cavities with embedded silicon nitride membranes, fabricated using a monolithic surface-micromachining process. The presence of the suspended membranes was confirmed by confocal microscopy, and their properties were verified through optical studies and thermomechanical calibration of mechanical/vibrational noise spectra measured at room temperature and atmospheric pressure. The cavities exhibit reflectance-limited finesse (F ∼ 103) and wavelength-scale mode volumes (VM ∼ 10·λ3). The short cavity length (L ∼ 2·

... Show More
View Publication
Scopus (9)
Crossref (9)
Scopus Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Heavy Metals from Industrial Wastewater by Using RO Membrane
...Show More Authors

Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process
...Show More Authors

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Implementation of hierarchically porous zeolite-polymer membrane for Chromium ions removal
...Show More Authors
Abstract<p>This work deals with the preparation of a zeolite/polymer flat sheet membrane with hierarchical porosity and ion-exchange properties. The performance of the prepared membrane was examined by the removal of chromium ions from simulated wastewater. A NaY zeolite (crystal size of 745.8 nm) was prepared by conventional hydrothermal treatment and fabricated with polyethersulfone (15% PES) in dimethylformamide (DMF) to obtain an ion-exchange ultrafiltration membrane. The permeate flux was enhanced by increasing the zeolite content within the membrane texture indicating increasing the hydrophilicity of the prepared membranes and constructing a hierarchically porous system. A membrane contain</p> ... Show More
View Publication
Scopus (33)
Crossref (19)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Renewable And Sustainable Energy Reviews
Superiority of liquid membrane-based purification techniques in biodiesel downstream processing
...Show More Authors

View Publication
Scopus (16)
Crossref (20)
Scopus Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Desalination of Highly Saline Water Using Direct Contact Membrane Distillation (DCMD)
...Show More Authors

In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.

View Publication Preview PDF
Crossref (6)
Crossref