Preferred Language
Articles
/
anif7KABuRolNscLQfW_
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been utilized to strengthen a semi-empirical model, based on a second-degree polynomial, to predict recovery efficiency. The model was tested using ANOVA software (Design expert®) and found acceptable R-Squared were (0.9673). Yield responseurface and contour plots have been created using the developed model, which revealed the presence of high-recovery plateaus whose specs will be useful in controlling pilot or industrial scale future devices to ensure economic feasibility.

Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Chemistry And Materials Research
Simple RP-HPLC Method for Estimation of Furosemide, Carbamazepine, Diazepam and Carvedilol in Bulk and Pharmaceutical Dosage Forms
...Show More Authors

A simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and li

... Show More
Publication Date
Thu Jan 01 2009
Journal Name
2009 Wri International Conference On Communications And Mobile Computing
Optimization of Cooperation Sensing Spectrum Performance
...Show More Authors

Cooperation spectrum sensing in cognitive radio networks has an analogy to a distributed decision in wireless sensor networks, where each sensor make local decision and those decision result are reported to a fusion center to give the final decision according to some fusion rules. In this paper the performance of cooperative spectrum sensing examines using new optimization strategy to find optimal weight and threshold curves that enables each secondary user senses the spectrum environment independently according to a floating threshold with respect to his local environment. Our proposed approach depends on proving the convexity of the famous optimization problem in cooperative spectrum sensing that stated maximizing the probability of detec

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Apr 20 2018
Journal Name
Iaes International Journal Of Artificial Intelligence (ij-ai)
Optimization of Digital Histopathology Image Quality
...Show More Authors

One of the biomedical image problems is the appearance of the bubbles in the slide that could occur when air passes through the slide during the preparation process. These bubbles may complicate the process of analysing the histopathological images. The objective of this study is to remove the bubble noise from the histopathology images, and then predict the tissues that underlie it using the fuzzy controller in cases of remote pathological diagnosis. Fuzzy logic uses the linguistic definition to recognize the relationship between the input and the activity, rather than using difficult numerical equation. Mainly there are five parts, starting with accepting the image, passing through removing the bubbles, and ending with predict the tissues

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt.  in Class II cavity preparation .

Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used    group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of  composite:

... Show More
View Publication
Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Kinetics of Hydrodesulfurization Catalyst Rejuvenation Process
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Apr 01 2024
Journal Name
Chemical Engineering Research And Design
Treatment of petroleum refinery wastewater by a combination of anodic oxidation with photocatalyst process: Recent advances, affecting factors and future perspectives
...Show More Authors

View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Fri Apr 27 2012
Journal Name
Al-qadisiyah Journal For Science
Synthesis and Characterization of azo Compound 5-(2-Benzoic acid azo)-8-hydroxy quinoline as Bidentate Ligand and It’s Complexeswith Co (II), Ni (II) and Cu (II) .
...Show More Authors

Coupling reaction of 2-amino benzoic acid with the 8-hydroxy quinoline gave the azo ligand (H2L): 5-(2-benzoic acid azo )-8-hydroxy quinoline.Treatment of this ligand with some metal ions (CoII, NiII and CuII ) in ethanolic medium with a (1:2) (M:L) ratio yielded a series of neutral complexes with general Formula[M(HL)2],where: M=Co(II), Ni(II) and Cu(II), HL=anion azo ligand (-1).The prepared complexes were characterized using flame atomic absorption,FT-IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements.

Publication Date
Wed Mar 19 2008
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Synthesis and Characterisation of Novel Cobalt (li), Copper (II) and Mercury (II) Complexes of Poly Vinyl Urethanised Oxime
...Show More Authors

The reaction of poly (vinyl alcohol) (PV A) with Urea in (DMSO) resulted in uerthanised oxim, wr,ich reacted with diacetylmonoxime in a (DY.ISOfmethanol) to give anew type (N2) polymeric bidentate imine oxime ligand [HL], The ligand was reacted with MCh (where M= Co, Cu, and Hg). Under reflux in a (DMF/Methanol) mixture with (I:1) ratio to give Complexes of the general formula [M (T.)2]X, (where M= Co,Hg, Cu). All .:ompouncs have been characterized by spectroscopic methods [IR, U.V.-Vis, A tomi<;absorption] microanalysis along with conductivity measurements, from the above:: data the proposed molecular structure for Co,Cu, and Hg is a distorted. Tetrahedml

Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Zn (II) and Cu (II) Ions Using PEG (300) - KCl Salt Aqueous Two-Phase Systems
...Show More Authors

In this paper the process of metal ions extraction (Zn(II) and Cu(II)) was studied in PEG-KCl aqueous two phase system was investigated without using an extracting agent. The experimental runs were performance at constant temperature (25 oC), constant mixing time (30 min), and constant PH of the solution (about 3). The effect of KCl salt concentration (from 10% to 25%), volumetric phase ratio of PEG solution to KCl solution (from 0.5 to 2), and the initial metal ion concentration (from 0.25 ml to 2 ml of 1 gm/L solution) were investigated on the percent extraction of Zn(II) and Cu(II). The results indicated that the percent extraction of metal ions increase with increasing of salt concentration and phase ratio, and slightly de

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 13 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Marginal leakage of amalgam and modern composite materials related to restorative techniques in class II cavity (Comparative study)
...Show More Authors

Background: Restoration of the gingival margin of Class II cavities with composite resin continues to be problematic, especially where no enamel exists for bonding to the gingival margin. The aim of study is to evaluate the marginal leakage at enamel and cementum margin of class II MOD cavities using amalgam restoration and modern composite restorations Filtek™ P90, Filtek™ Z250 XT (Nano Hybrid Universal Restorative) and SDR bulk fill with different restoratives techniques. Materials and method: Eighty sound maxillary first premolar teeth were collected and divided into two main groups, enamel group and cementum group (40 teeth) for each group. The enamel group was prepared with standardized Class II MOD cavity with gingival margin (1 m

... Show More
View Publication Preview PDF