The fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been accomplished and experimentally tested in order to enhance the PV panel efficiency, especially at hot climates. The proposed glazing system can simultaneously perform two functions, firstly, working as a cooling tool for reducing the stored heat in the PV panel during its work and secondly as an optical filter for sun light spectrum. Optimum design factors with their levels for the glazing system were calculated according to Taguchi method. Test experiments were carried out in Baghdad city on the 20th and 21st July 2016 on the tracker with and without using the WFDG system. The obtained results show that, the PV panel temperature with using the WFDG system was significantly dropped by 44% and its efficiency increased maximally by 36.6% at solar irradiance of 1213W/m2 as compared with conventional one.
The coronavirus disease 2019 (COVID-19) pandemic and the infection escalation around the globe encourage the implementation of the global protocol for standard care patients aiming to cease the infection spread. Evaluating the potency of these therapy courses has drawn particular attention in health practice. This observational study aimed to assess the efficacy of Remdesivir and Favipiravir drugs compared to the standard care patients in COVID-19 confirmed patients. One hundred twenty-seven patients showed the disease at different stages, and one hundred and fifty patients received only standard care as a control group were included in this study. Patients under the Remdesivir therapy protocol were (62.20%); meanwhile, there (30.71
... Show MoreSince the law is the tool for implementing the state’s public policies, it is natural that its provisions (or at least some of them) seek to preserve human dignity as the source on which all rights and freedoms are based. One of the examples of humanizing the provisions of the law in France is what is known as the winter truce. What is this truce, what are the justifications for granting it, what is its historical origin, how did the legislative treatment of it develop, what are the similarities and differences between it and other legal periods included in French law, what is the scope of its application, and what are the effects resulting from it. These questions and others are what we will try to answer through this research.
In this study NiO - CoO bimetallic catalysts are prepared with two Ni/Co ratios (70:30 and 80: 20) using the precipitation method of nitrate salts. The effects of Ni /Co ratio and preparation methods on the catalyst are analyzed by using different characterization techniques, i.e. atomic absorption (AA) , XRD, surface area and pore volume measurements according to the BET method . The results indicate that the best catalyst is the one containing the percentage of Ni :Co ( 70 : 30 ). Experiments indicate that the optimal conditions to prepare catalyst are stirring for three hours at a temperature of 60oC of the preparation , pH= (8-9) , calcination temperature at 400oC for two hours
... Show MoreThe aim of this research to examine the impact of different level of Insulin certain biomarkers of local roosters semen after being cooling for varying lengths of periods, roosters semen pooled, diluted with extender, and distributed randomly among five groups: Diluted semen put through the semen cryopreservation technique; the control treatment (C1) 0 insulin; (C2) contained 4 IU/insulin; (C3) contained 5 IU/insulin; (C4) contained 6 IU/insulin; and (C5) contained 7 IU/insulin. After 0, 24, 48 and 72 hours, cooling semen were evaluated for plasma membrane integrity(MI), acrosome integrity(AI), malondialdehyde (MDA) and total antioxidant capacity (TCA). The result showed significant d
The use of worn-out agricultural nozzles in pesticide application has a negative effect on the efficiency and cost of the application process. It also has an effect on environmental pollution due to an excessive amount of pesticide being applied when spraying with worn-out nozzles. In this paper, the resistance to wear of three different internal design hydraulic nozzles was ascertained. Changes in the flow rate and spray distribution as a result of this wear were also investigated. The wear test was done inside a closed system, and it was accelerated using an abrasive material to generate 100 h of wear. The tested nozzles were the Turbo TeeJet (TT)-twin chambered, Turbo Twinjet (TTj60)-dual outlet, and Drift Guard (DG)-pre-orifice.
... Show More: Clobetasol propionate (CP) is a potent corticosteroid used for skin conditions but often causes side effects due its systemic absorption. To improve its solubility and reduce it side effects (like skin irritation, skin atrophy, hypopigmentation and steroidal acne), Microsponge (Msg) has been employed as a unique three-dimensional particle that can encapsulate hydrophilic and lipophilic drugs. This study aims to develop and evaluate CP Msg-loaded hydrogels. Two Clobetasol-loaded ethylcellulose-based Msg formulas were prepared using the quasi-emulsion solvent diffusion method, then they were incorporated into Carbopol hydrogel. Two ratios of Carbopol 940 (1% and 1.5% w/w) were used. The prepared hydrogel were assessed for appearance, pH, dr
... Show MoreObjective: The aim of this study is to identify the impact of training education program applied on
nurse-midwife practice concerning care during third stage of labor in labor room. Examine the
relationship between their knowledge regarding practices and some Demographic information’s.
Methodology: A quasi-experimental design conducted on non-probability (purposive) sample of fifty
two nurse-midwives selected during period from3
th August to 10thNovember 2011. The study is
conducted at the Ministry of Health (Baghdad health directorate in Al-Karhk and Al-Risafa sector) in
four hospitals. The questionnaire form is consisted of three parts which included demographic data,
knowledge concerning practice during third
Pyrolysis of high density polyethylene (HDPE) was carried out in a 750 cm3 stainless steel autoclave reactor, with temperature ranging from 470 to 495° C and reaction times up to 90 minute. The influence of the operating conditions on the component yields was studied. It was found that the optimum cracking condition for HDPE that maximized the oil yield to 70 wt. % was 480°C and 20 minutes. The results show that for higher cracking temperature, and longer reaction times there was higher production of gas and coke. Furthermore, higher temperature increases the aromatics and produce lighter oil with lower viscosity.
Background: Insertion sequence is a short DNA sequence encode for proteins implicated in the transposition activity. Transposase catalyzes the enzymatic reaction allowing the insertion sequence to +9*lo2 move. ;qqa;.
Objective: To study the sequencing of transposase gene, tnp, IS1216V of S. aureus isolated from food and then compared with that documented in National Center for Biotechnology Information (NCBI).
Methods: Food samples of animal
... Show MoreThis study was conducted to determine the effects of concentration of hydrochloric acids, temperature, and time on the hydrolysis of soya proteins (defatted soya flour) by determining the value of total protein nitrogen concentration, and amino nitrogen concentration of protein, peptides, and amino acids, and then calculated the hydrolysis rate of proteins.
The variables of the conditions of hydrolysis process was achieved in this study with the following range value of tests parameter:
- Concentration of HCl solution ranged between 1-7 N,
- Hydrolysis temperature ranged between 35-95 °C, and
- The time of hydroly