Preferred Language
Articles
/
alkej-832
Removal of Ciprofloxacin Antibiotic from Synthesized Aqueous Solution Using Three Different Metals Nanoparticles Synthesized Through the Green Method
...Show More Authors

This study investigates the possibility of removing ciprofloxacin (CIP) using three types of adsorbent based on green-prepared iron nanoparticles (Fe.NPs), copper nanoparticles (Cu. NPS), and silver nanoparticles (Ag. NPS) from synthesized aqueous solution. They were characterized using different analysis methods. According to the characterization findings, each prepared NPs has the shape of a sphere and with ranges in sizes from of 85, 47, and 32 nanometers and a surface area of 2.1913, 1.6562, and 1.2387 m2/g for Fe.NPs, Cu.NPs and Ag.NPs, respectively. The effects of various parameters such as pH, initial CIP concentration, temperature, NPs dosage, and time on CIP removal were investigated through batch experiments. The results showed that 10 mg/L CIP was removed by 100%, 92% and 79% within 180 min using Fe.NPs, Cu.NPs, and Ag.NPs respectively. In addition to this, kinetic models of the adsorption and mechanism of CIP removal were studied. The cinematic analysis demonstrated that adsorption is a physics adsorption mechanism with an energy of 0.846 kJ.mol-1, 1.720 kJ.mol-1, and 3.872 kJ.mol-1, while the low activation energies of 17.660 kJ.mol-1, 13.221 kJ.mol-1, and 14.060 kJ.mol-1 for Fe.NPs, Cu.NPs, and Ag.NPs respectively. The kinetic removal process follows a pseudo-first-order model following a physical diffusion-controlled reaction. The data on adsorption was analyzed using the Langmuir, Freundlich, Temkin, and Dubinin models, as well as thermodynamic factors, indicating that the process is appropriate and endothermic sorption. The most practical adsorbent was Fe.NPs

    

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
LEAD Removal from Industrial Wastewater by Electrocoagulation process
...Show More Authors

This investigation was carried out to study the treatment and recycling of wastewater in the Battery industry for an effluent containing lead ion. The reuse of such effluent can only be made possible by appropriate treatment method such as electro coagulation.
The electrochemical process, which uses a cell comprised aluminum electrode as anode and stainless steel electrode as cathode was applied to simulated wastewater containing lead ion in concentration 30 – 120 mg/l, at different operational conditions such as current density 0.4-1.2 mA/cm2, pH 6 -10 , and time 10 - 180 minute.
The results showed that the best operating conditions for complete lead removal (100%) at maximum concentration 120 mg/l was found to be 1.2 mA/cm2 cur

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Color Removal from Waste Water by Chemical Coagulation
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The correction of the line profiles for x-ray diffraction peaks by using three analysis methods
...Show More Authors

In this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.

View Publication
Scopus (14)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun May 02 2021
Journal Name
Knowledge-based Engineering And Sciences
Lead sorption from aqueous solutions by kaolinite: laboratory experiments
...Show More Authors

The lead has adverse effects in contamination the aquatic environment, for this reason, a laboratory simulation was conducted using kaolinite collected from the Ga’ara Formation at western Iraq to be considered as a natural sorbent material that can be addressed Pb2+ from the aqueous environments. The Energy-Dispersive X-ray Spectroscopy and atomic absorption spectroscopy clarifying very fine grains and pure phase with a very little quantity of quartz and has a number of active sites for adsorption. The sorption of kaolinite for the Pb2+ has been carefully tested by several designed laboratory experiments. Five lead solutions of different concentrations (25, 50, 75, 100 and 125 ppm) were tested under different values of pH (1.3-9)

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Advances In Intelligent Systems And Computing
Forecasting by Using the Optimal Time Series Method
...Show More Authors

View Publication
Scopus (20)
Crossref (10)
Scopus Crossref
Publication Date
Mon Apr 20 2026
Journal Name
Applied Physics A
The antibacterial property of ZnO nanopowder with different concentration of sodium hydroxide prepared by hydrothermal method
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Materials Today: Proccedings
Nanomaterials usage as adsorbents for the pollutants removal from waste water; areview
...Show More Authors

Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Occurrence and pattern of antibiotic resistance among dental plaque bacteria from gingivitis patients and their clinical correlation
...Show More Authors

Background: A diverse group of bacteria live in biofilms in the oral cavity. On dental surfaces biofilms form plaque that is potentially involved in caries and periodontal diseases. Periodic studying of plaque microflora and their antimicrobial sensitivity patterns strongly affects the clinical practice in plaque-induced oral diseases. Materials and methods: Dental plaque samples were collected from 22 patients having ages ranged between 33 and 49 years with gingivitis that met the study criteria. Plaque, gingival and gingival bleeding indices (PI, GI, GBI) were measured for each patient. Laboratory procedures included microbiological examination of plaque samples followed by antibiotic sensitivity testing using disc diffusion method were

... Show More
View Publication
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Recovery from Brine Solution by Forward Osmosis Process
...Show More Authors

The present work aims to study the possibility of utilization a forward osmosis desalination process as an alternative method to extract water from brine solution rejected from reverse osmosis process.
Experiments conducted in a laboratory–scale forward osmosis (FO) unit in cross flow flat sheet membrane cell yielded water flux ranging from (0.0315 to 0.56 L/m2 .min) when using CTA membrane,and ranging from (0.419 to 2.785 L/m2 .min) for PA membrane under 0.4 bar. Two possible membrane orientations were tested. Sodium chloride with high concentrations was used as draw solution solute. The effect of membrane orientation on internal concentration polarization (ICP) was studied. Two regimes of ICP; dilutive and concentrative were desc

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Iron from Aqueous Chloride Media in Presence of Aluminum
...Show More Authors

The extraction of iron from aqueous chloride media in presence of aluminum was studied at different kinds of extractants(cyclohexanone, tributyl phosphate, diethyl ketone), different values of normality (pH of the feed solution), agitation time, agitation speed, operating temperature, phase ratio (O/A), iron concentration in the feed, and extractant concentration]. The stripping of iron from organic solutions was also studied at different values of normality (pH of the strip solution) and phase ratio (A/O). Atomic absorption spectrophotometer was used to measure the concentration of iron and aluminum in the aqueous phase throughout the experiments.The best values of extraction coefficient and stripping coefficient are obtained under the

... Show More
View Publication Preview PDF