Preferred Language
Articles
/
alkej-806
Study of Microbial Desalination Cell Performance; Power Generation and Desalination Efficiency using Pure Oxygen in a Cathode Chamber
...Show More Authors

Microbial Desalination Cell (MDC) is capable of desalinating seawater, producing electrical power and treating wastewater. Previously, chemical cathodes were used, which were application restrictions due to operational expenses are quite high, low levels of long-term viability and high toxicity. A pure oxygen cathode was using, external resistance 50 and 150 k Ω were studied with two concentrations of NaCl in the desalination chamber 15-25 g/L which represents the concentration of brackish water and sea water. The highest energy productivity was obtained, which amounted to 44 and 46 mW/m3, and the maximum limit for desalination of saline water was (31% and 26%) for each of 25 g / L and 15 g / L, respectively, when using an external resistance of 150 KΩ. At 50 KΩ, 13 and 12 mW/m3 were obtained, and the maximum desalination limit were 20% and 2% when using 25 g / L and 15 g / L, respectively. The concept of the mixing process was introduced in the desalination chamber to improve the performance of the system, where the highest energy productivity was obtained, which amounted 45 and 47 mW/m3, and the percentage of salt removal in the desalination chamber were 40% and 55% when using 15 g/L and 25 g/L and 150 KΩ, respectively. This study demonstrated a promising approach to using the mixing process in the desalination room in order to increase the desalination and electrical productivity.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Al-nahrain Journal Of Science
Adsorption of P-Aminodiphenylamine with Iodine Charge Transfer Complex on Surface Arundo Plant
...Show More Authors

charge transfer complex formed by interaction between the p- aminodiphenylamine (PADPA) as electron donor with iodine as electron acceptor in ethanol at 250C as evidenced by color change and absorption. The spectrum obtained from complex PADPA – Iodine shows absorptions bands at 586 nm. All the variables which affected on the stability of complex were studies such as temperature, pH, time and concentration of acceptor. The linearity of the method was observed within a concentration rang (10–165) mg.L-1 and with a correlation coefficient (0.9996), while the molar absorbitivity and sandell sensitivity were (4643.32) L.mol-1.cm-1 and (0.0943) μg.cm-2, respectively. The adsorption of complex PADPA–I2 was studied using adsorbent surfaces

... Show More
Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Calculate the one – expectation to electronic charge of atomic system contiun two electron
...Show More Authors

The aim of this work is to calculate the one- electron expectation value of the electronic charge of atomic system Z=2,3….7 and we compare with He atom . the electronic density function D(r1) of He atom and like ions are evaluated . using Hartree –Fock wave.

View Publication Preview PDF
Crossref
Publication Date
Thu Sep 06 2018
Journal Name
Digest Journal Of Nanomaterials And Biostructures
HIGHER PHOTO SENSITIVITY OF Co-Y-OXIDE NANO STRUCTURE SYNTHESIZED BY HYDROTHERMAL METHOD
...Show More Authors

In this work, Co-Y-oxide Nano Structure is successfully synthesized via hydrothermal method. The XRD analysis, SEM analysis, optical, electrical and photo sensing properties have been investigated for Co3O4 and Co-Y-oxide thin films. The X-ray diffraction (XRD) analysis reveals that all films are polycrystalline in nature, having cubic structure. The SEM images of thin films clearly indicates that Co3O4 possesses nanosphere like structure and flower like for Co-Y-oxide. The optical properties show that the optical energy gap follows allowed direct electronic transition calculated using Tauc equation and it increases for Co-Y-oxide. The photo sensing properties of thin films are investigated as a function of time at different wavelengths to

... Show More
Scopus (3)
Scopus
Publication Date
Sun Jan 01 2012
Journal Name
مجلة الهندسة والتكنولوجيا
Histopathological Effects of Burkholderia Mallei Isolated from Patients with Wound Infections on Mice
...Show More Authors

Publication Date
Wed May 10 2017
Journal Name
Australian Journal Of Basic And Applied Sciences
Photometric Viewpoint to the Structure of Spiral Galaxy NGC 3351 with griz-Filters
...Show More Authors

The term ‘photometry’ refers to the accurate determination of the apparent brightness of an astronomical object. Until roughly 1980, nearly all astronomical photometry was done by means of analog measurements of photographic plates, or by analog or digital (photon-counting) techniques with photomultipliers. These photometers produced brightness readings which were typically displayed on dials, plotted on strip charts or printed on strips of paper, and it was often quite practical to analyse these raw data with pencil, paper and a slide rule or table of logarithms. However, during the late 1970s electronic area detectors for astronomy became more advanced: first, for a brief period, television-type cameras were employed, but these were s

... Show More
View Publication
Publication Date
Wed May 01 2013
Journal Name
Ieee Journal Of Biomedical And Health Informatics
Classification of Finger Movements for the Dexterous Hand Prosthesis Control With Surface Electromyography
...Show More Authors

View Publication
Scopus (303)
Crossref (275)
Scopus Clarivate Crossref
Publication Date
Fri Aug 28 2020
Journal Name
Iraqi Journal Of Science
Numerical Simulation of Immiscible CO2-Assisted Gravity Drainage Process to Enhance Oil Recovery
...Show More Authors

The Gas Assisted Gravity Drainage (GAGD) process has become one of the most important processes to enhance oil recovery in both secondary and tertiary recovery stages and through immiscible and miscible modes.  Its advantages came from the ability to provide gravity-stable oil displacement for improving oil recovery, when compared with conventional gas injection methods such as Continuous Gas Injection (CGI) and Water – Alternative Gas (WAG). Vertical injectors for CO2   gas were placed at the top of the reservoir to form a gas cap which drives the oil towards the horizontal oil producing wells which are located above the oil-water-contact. The GAGD process was developed and tested in vertical wells to increase oil r

... Show More
Crossref (5)
Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Renewable Energy
Biodiesel production by esterification of oleic acid over zeolite Y prepared from kaolin
...Show More Authors

View Publication
Scopus (141)
Crossref (130)
Scopus Clarivate Crossref
Publication Date
Thu Feb 09 2017
Journal Name
International Journal Of Pharmacy Practice
Factors influencing the degree of physician–pharmacist collaboration within Iraqi public healthcare settings†
...Show More Authors
Abstract<sec> <title>Objectives

Medication safety and effectiveness can be improved through interprofessional collaboration. The goals of this study were to measure the degree of physician–pharmacist collaboration within Iraqi governmental healthcare settings and to investigate factors influencing this collaboration.

Methods

This cross-sectional study was conducted in Al-Najaf Province using the Collaborative Working Relationship Model and Physician–Pharmacist Collaborative Instrument (PPCI). Four phar

... Show More
View Publication
Scopus (20)
Crossref (13)
Scopus Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Lubricants
Terahertz Time Domain Spectroscopy to Detect Different Oxidation Levels of Diesel Engine Oil
...Show More Authors

Diesel engine oil was subjected to thermal oxidization (TO) for six periods of time (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h) and was subsequently characterized by terahertz time domain spectroscopy (THz-TDS). The THz refractive index generally increased with oxidation time. The measurement method illustrated the potential of THz-TDS when a fixed setup with a single cuvette is used. A future miniaturized setup installed in an engine would be an example of a fixed setup. For the refractive index, there were highly significant differences among the oxidation times across most of the 0.3–1.7 THz range.

View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref