Preferred Language
Articles
/
alkej-801
Kinetics of Electrochemical Removal of Nickel using Bio-electrochemical Reactor with Packed Bed Rotating Cylinder Cathode
...Show More Authors

The kinetics of nickel removal from aqueous solutions using a bio-electrochemical reactor with a packed bed rotating cylinder cathode was investigated. The effects of applied voltage, initial nickel concentration, the rotation speed of the cathode, and pH on the reaction rate constant (k) were studied. The results showed that the cathodic deposition occurred under mass transfer control for all values of the applied voltage used in this research. Accordingly, the relationship between concentration and time can be represented by a first-order equation. The rate constant was found to be dependent on the applied voltage, initial nickel concentration, pH, and rotation speed. It was increased as the applied voltage increased and decreased as the initial concentration increased. Its relation to the applied voltage can be fitted as follows:

where ko =0.01695 min-1 and -β=0.431. pH and rotation speed have two dissimilar effects on the rate constant. Increasing the pH from 3-6 leads to an increase in the rate constant, while a decrease in the rate constant beyond pH=6 has occurred. Increasing the rotation from 100 to 300 rpm results in an increase in the rate constant. However, the rate constant decreases significantly beyond a rotation speed of 300 rpm.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Kinetic and Theoretical Study of Removal Gentian Violet from Aqueous Solution Using Stachy Plant
...Show More Authors

     The main parameters and methods influencing the removal of Gentian Violet (GV) dye from aqueous media were investigated using a stachy plant in this study. The surface of the stachy plant was determined using FTIR spectra. Adsorption is influenced by the adsorbent's characteristic groups. The research took into account the usual conditions for GV dye adsorption by the stachy plant, such as the impact of contact time. Mass dosage , after 0.3 g the amount of adsorbed dye declines. Study pH and ionic strength, the results obtained showed that at pH 3 the largest adsorption of (GV) was seen, while at pH 9, the lowest adsorption was observed  at 298 K, the adsorption kinetics and equilibrium constants were achieved, and the equilibr

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Removal of Suspended Solids Using Pumice Stone in Integrated Fixed Film Activated Sludge Process
...Show More Authors

Wastewater treatment plants operators prefer to make adjustments because they are more cost effective, to use the existing tank instead of building new ones. In this case an imported materials would be  used as bio-loads to increase biomass and thus maintain efficiency as the next organic loading increases.In the present study, a local substance "pumice stone" was used as a biological carrier in the aeration tank, and the experiments were carried out in five stages: without biological carriers, filling ratio of 4%,10%,20%, and25% with pumice stone, the maximum organic loading at each stage (1.1884, 1.2144, 1.9432, 2.7768, 3.3141)g BOD /l.d respectively.Other experiments were carried out to determine the best filling ratio, the SS remova

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Ecological Engineering
Heavy Metals Removal from Simulated Wastewater using Horizontal Subsurface Constructed Wetland
...Show More Authors

This study aimed to assess the efficiency of Nerium oleander in removing three different metals (Cd, Cu, and Ni) from simulated wastewater using horizontal subsurface flow constructed wetland (HSSF-CW) system. The HSSF-CW pilot scale was operated at two hydraulic retention times (HRTs) of 4 and 7 days, filled with a substrate layer of sand and gravel. The results indicated that the HSSF-CW had high removal efficiency of Cd and Cu. A higher HRT (7 days) resulted in greater removal efficiency reaching up to (99.3% Cd, 99.5% Cu, 86.3% Ni) compared to 4 days. The substrate played a significant role in removal of metals due to adsorption and precipitation. The N. oleander plant also showed a good tolerance to the uptake of Cd, Cu, and Ni ions fr

... Show More
Crossref (14)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Ecological Engineering
Heavy Metals Removal from Simulated Wastewater using Horizontal Subsurface Constructed Wetland
...Show More Authors

This study aimed to assess the efficiency of Nerium oleander in removing three different metals (Cd, Cu, and Ni) from simulated wastewater using horizontal subsurface flow constructed wetland (HSSF-CW) system. The HSSF-CW pilot scale was operated at two hydraulic retention times (HRTs) of 4 and 7 days, filled with a substrate layer of sand and gravel. The results indicated that the HSSF-CW had high removal efficiency of Cd and Cu. A higher HRT (7 days) resulted in greater removal efficiency reaching up to (99.3% Cd, 99.5% Cu, 86.3% Ni) compared to 4 days. The substrate played a significant role in removal of metals due to adsorption and precipitation. The N. oleander plant also showed a good tolerance to the uptake of Cd, Cu, and Ni ions fr

... Show More
Scopus (17)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
DYE REMOVAL FROM TEXTILE WASTEWATER BY COAGULATION USING ALUM AND PAC
...Show More Authors

Removal of solar brown and direct black dyes by coagulation with two aluminum based
coagulants was conducted. The main objective is to examine the efficiency of these
coagulants in the treatment of dye polluted water discharged from Al-Kadhymia Textile
Company (Baghdad-Iraq). The performance of these coagulants was investigated through
jar test by comparing dye percent removal at different wastewater pH, coagulant dose,
and initial dye concentration. Results show that alum works better than PAC under acidic
media (5-6) and PAC works better under basic media (7-8) in the removal of both solar
brown and direct black dyes. Higher doses of PAC were required to achieve the
maximum removal efficiency under optimum pH co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 16 2017
Journal Name
Tikrit Journal For Dental Sciences
Evaluation of Apical Transportation and Curve Straightening of Curved Root Canals after Preparation with Different Nickel - Titanium Rotary Systems (Comparative in Vitro Study)
...Show More Authors

The goals of endodontic preparation were to shape and clean the space of the root canal and remove microorganisms, affected dentin and pulp, the apical foramen and the canal curve should be protected from being transported during endodontic canal preparation. The aim of this study was to evaluate the curve straightening of curved root canals and apical transportation after preparation with four rotary systems. Forty mesial roots of the lower 1st molars teeth only the mesiobuccal canals were used, these roots were immersed into cold clear acrylic , the teeth roots divided into four groups according to rotary system used for preparation of the canals (ten roots for each group):. group I: ProTaper Next rotary system, group II: IRaCe Plus rotar

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Evaluation of the Centering Ability and Canal Transportation of Simulated S-Shaped Canals Instrumented with Different Nickel –Titanium Rotary Systems
...Show More Authors

Background: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Improvement the Superconducting properties of TlBa2 Ca2 Cu3xNix O 9-δ superconducting compound by partial substitution of copper with nickel oxide on the
...Show More Authors

View Publication
Scopus (21)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Experimental Evaluation Use of Semifluidized Bed Adsorber for the Treatment of P-chlorophenol and O-cresol in Wastewater using Activated Carbon as Adsorbent
...Show More Authors

In the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). In

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy: IOP Level After SO Removal
...Show More Authors

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.

Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)

Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO

... Show More
View Publication Preview PDF
Scopus Crossref