This paper represents an experimental study on the application of smart control represented by the use of the fuzzy logic controller. Two-link flexible manipulators that are used in airspace and military applications are made of flexible materials characterized by low frequency and damping ratio. To solve this problem, this paper proposes the use of smart materials (piezoelectric transducers), where each link is bonded with a pair of piezoelectric transducers that act as a sensor and another as an actuator. As the arm vibrates because of the movement generated by the motor, this voltage is controlled by a regulator inside the LABVIEW® 2020 software and sends the output control voltage to the piezoelectric actuator. Experimental results show that fuzzy logic control was efficient during high amplitude and led to pronounced results in suppressing vibrations within a short time. Fuzzy logic gives more flexibility to the designer and allows him to control the system through its simple implementation. This differs from classical control, which requires a mathematical model.
The inelastic longitudinal electron scattering form factors are calculated for the low-lying excited states of 7Li {the first excited state 2121TJ (0.478 MeV) and the second excited state 2127TJ (4.63 MeV)}. The exact value of the center of mass correction in the translation invariant shell model (TISM) has been included and gives good results. A higher 2p-shell configuration enhances the form factors for high q-values and resolves many discrepancies with the experiments. The data are well described when the core polarization (CP) effects are included through effective nucleon charge. The results are compared with other theoretical models.
Keyword: 7Li inelastic electron scattering form factors calculated with exact
The applications of mobile robots in rescue scenarios, surviving to search, and exploration for outdoor navigation have received increasing attention due to their promising prospects. In this paper, a simulation of a differential wheeled mobile robot was presented, implementing a Global Positioning System (GPS) data points to specified starting points, final destination, and total error.
In this work, a simple kinematic controller for polar coordinate trajectory tracking is developed. The tracking between two points, pose to pose, was specified by using the GPS data points. After that, the geodesy (GEO) formulation was used to convert the geodesy coordinate to Euclidean or polar coordinate. The Haversine equation
... Show MoreBackground: This study aimed to determine the cephalometric values of tetragon analysis on a sample of Iraqi adults with normal occlusion. Material and methods: Forty digital true lateral cephalometric radiographs belong to 20 males and 20 females having normal dental relation were analyzed using AutoCAD program 2009. Descriptive statistics and sample comparison with Fastlicht norms were obtained. Results: The results showed that maxillary and mandibular incisors were more proclined and the maxillary/mandibular planes angle was lower in Iraqi sample than Caucasian sample. Conclusion: It's recommended to use result from this study when using tetragon analysis for Iraqis to get more accurate result.
Visceral leishmaniasis (VL) or kala-azar is one of the worlds most neglected tropical diseases in mortality and fourth in morbidity, rK39 dipstick was used to diagnose the suspected infected patients as cheapest simple technique which can differentiate recent from chronic infection, for disease out-coming, naïve T-lymphocyte cells should be differentiated into pathogen-specific immunity responses, such as T-helper 1(Th-1) or (Th-2). HLA-G is a special protein defined as nonclassical HLA class I molecule can suppress the immune system through prevention of T-cell function by foul all T-cell mechanisms. So, this study aimed to detect and evaluate the level of sHLA-G in the sera of patients infected with VL. The results showed that there was
... Show MoreBlood samples were collected from (31) pregnant women infected with cytomegalovirus , also (15) blood samples were collected from congenitally infected infants, and (20),(15),(15) blood samples were collected from pregnant women ,non pregnant and infants, respectively, all of them were as control groups. CMV infection identified by using ELISA assay to detect specific CMV IgM & IgG in sera. The results of lymphocyte transformation showed a significant decrease when phytoheamagglutinin (PHA) used as stimulator, lymphocytes response in infected pregnant women was lower than that of non infected pregnant women as well as non pregnant women. Result also showed a significant decrease in the ability of lymphocyte division in healthy pregnant w
... Show MoreThis paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6mm), the diameter of the shear connectors (10, 12, and 16mm), and the connector spacing (100, 200, and 250mm). The test results sh
... Show More