Preferred Language
Articles
/
alkej-768
Effect of MIG Welding Parameters on the Mechanical Properties of AISI 304 Austenitic Stainless Steels
...Show More Authors

The present research  investigates joints welding of 304L austenitic stainless steel using metal inert gas (MIG) welding method. The research explores the effect of process parameters (arc voltage, wire feed rate, and electrode wire diameter) on the mechanical properties of stainless steel.  The above variables are varied  respectively with 18.5, 19, 19.5 V, 116, 127, 137 mm/s, and 0.8, 1, 1.2 mm, with E308L as a filler electrode. The design matrix of the experiments was determined using the design of experiment (DOE) program Minitab 17 based on the levels of input elements used. The Taguchi orthogonal matrix methodology (Taguchi) technique was used to develop some empirical analysis for the maximum tensile strength and proper surface hardness as a function of the welding parameters mentioned above. The ( ) analysis was used to statistically verify the model's adequacy. The results show that the wire feed rate had  the greatest effect on the tensile strength of the welded joints when choosing the medium level of arc voltage (19 V), while the arc voltage had a substantial influence on the micro-hardness of all welded joints. The weld-joint zone is given a higher micro-hardness value compared to the base metal zone.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of nano surface modification on CPTi dental implant using chemical method: mechanical and histological evaluation
...Show More Authors

Background The application of nanotechnology to biomedical surfaces is explained by the ability of cells to interact with nanometric features. The aim of this study was to consider the role of nanoscale topographic modification of CPTi dental implant using chemical etching method for the purpose of improving osseointegration. Materials and methods: Commercial pure titanium rod was machined into 20 dental implants. Each implant was machined in diameter about 3mm, length of 8mm (5mm was threaded part and 3mm was flat part). Implants were prepared and divided into 2 groups according to the types of surface modification method used: 1st group (10 implant) remained without nano surface modification (control), 2nd group include (10 implant) etche

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
The Acute and Chronic Toxicity of Copper on The Behavioral Responses and Hematological Parameters of Freshwater Fish, Common Carp (Cyprinus carpio L.)
...Show More Authors

The present study was conducted to examine toxicological effects of copper sulfate (Cu) in common carp fish (Cyprinus carpio L.). The LC50 (median lethal concentrations) of copper on Cyprinus carpio were 3.64, 3.36, 3.04, 2.65 mg/L respectively. In general, behavioral responses of the fishes exposed to copper included uncontrolled swimming, erratic movements, loss of balance, swam near the water surface with sudden jerky movements. Haematological parameters such, red blood cells (RBC), white blood cells (WBC), haemoglobin (Hb), Packed cell volume (PCV), mean cell volume (MCV) mean cell haemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC) were studied. The obtained results indicated that the (RBC) and (WBC) have increas

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Coated stainless steel archwires' discoloration measured by computerized system (An in-vitro study)
...Show More Authors

Background: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 09 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Thickness on the Electrical Conductivity and Hall Effect Measurements of (CIGS) films
...Show More Authors

The influence of different thickness (500, 1000, 1500, and 2000) nm on the electrical conductivity and Hall effect measurements have been investigated on the films of copper indium gallium selenide CuIn1-xGaxSe2 (CIGS) for x= 0.6.The films were produced using thermal evaporation technique on glass substrates at R.T from (CIGS) alloy. The electrical conductivity (σ), the activation energies (Ea1, Ea2), Hall mobility and the carrier concentration are investigated and calculated as function of thickness. All films contain two types of transport mechanisms of free carriers, and increases films thickness was fond to increase the electrical cAnductivity whereas the activation energy (Ea) would vary with films thickness. Hall Effect analysis resu

... Show More
Preview PDF
Publication Date
Mon Nov 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effects of three different types of intracoronal bleaching agents on shear bond strength of stainless steel and sapphire brackets bonded to endodontically treated teeth (An in vitro study)
...Show More Authors

Background: evaluate the effects of three different intracoronal bleaching agents on the shear bond strengths (SBS) and failure site of stainless steel and monocrystalline (sapphire) orthodontic brackets bonded to endodontically treated teeth using light cured orthodontic adhesive in vitro. Materials and methods: Eighty extracted sound human upper first premolars were selected, endondontically treated and randomly divided equally (according to the type of the brackets used) into two main groups (n = 40 per group). Each main group were subdivided (according to the bleaching agent used) into four subgroups 10 teeth each; as following : control (un bleached) group, hydrogen peroxide group (Hp) 35%, carbamide peroxide group (CP) 37% group and s

... Show More
View Publication Preview PDF
Publication Date
Sun May 30 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology,
Effect of Diabetes and Hypertension on Right Carotid Artery Intima Media Thickness and Variable Spectral Waveform Indices And Parameters in Relation To Age for Iraqi Patients
...Show More Authors

Background: Arterial stiffness is related with atherosclerosis and cardiovascular disease events. Patients with atherosclerotic disease show to have larger diameters, reduced arterial compliance and lower flow velocities. Aim of study : To compare between patients of two age groups with concomitant diseases diabetes and hypertension in regard to intima media thickness and blood flow characteristics in order to estimate the blood perfusion to the brain via the common and internal carotid arteries. Subject and Methods : 40 patients with (diabetic and hypertension) diseases were enrolled , they were classified according to age. Color Doppler and B mode ultrasound was used to determine lumen Diameter (D), Intima – media thickness (IMT)

... Show More
Scopus (1)
Scopus
Publication Date
Mon Nov 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and mechanical evaluation of the osseointegration of titanium implants by the modifications of thread design and/or coating with flaxseed (An experimental study on rabbits)
...Show More Authors

Background: Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and improve implant therapy.Implant threads should be designed to increase surface contact areathat induced better stability. In addition, implant surface coating with Flaxseed was used to enhance bone formation at the bone-implant interface. Materials and methods: Ninety-six commercially pure titanium (CpTi) screws were implanted in rabbits' tibiae and divided into three groups as dual-threaded group, flaxseed-coated group and control group. All groups were evaluated mechanically, histologically and radiographically after each healing periods (2, 4, 6 and 8) weeks and the resulting data were statistically analy

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 19 2018
Journal Name
Biomedical And Pharmacology Journal
Influence of Silver Nanoparticles on the Specific Properties of Acrylic Resin for Ocular Prosthesis
...Show More Authors

Scleral acrylic resin is widely used to synthesize ocular prosthesis. However, the properties of this material change over time, thus requiring the prosthesis to be refabricated. Many studies were conducted to improve these properties by reinforcing this material with nanoparticles. This study aims to evaluate the effect of silver nanoparticle powder on the mechanical properties (transverse flexural strength, impact strength, shear bond strength, surface microhardness, and surface roughness) of scleral acrylic resin used for ocular prostheses. Two concentrations were selected from the pilot study and evaluated for their effects on scleral acrylic resin properties. According to the pilot study, 0.01 and 0.02wt% AgNPs powder improved

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Study the effective addition of coumarin dye on the optical properties of poly (methyl meth acrylate)
...Show More Authors

The effect of adding different volume of coumarin dye (5, 15, 25 and 35) ml on optical properties of Poly (Methyl Meth Acrylate) was studied. Films of pure PMMA and PMMA with different volume of coumarin dye (5, 15, 25 and 35) ml were prepared using the casting technique. Transmission and absorption of the films were measured by using UV-VIS spectrometer technique type (100 Conc), in order to assess the type of transmission which was found an indirect transition. An optical energy gap of pure PMMA is (4.95e v) and after adding coumarin with volume (25, 35) ml, the energy gap for PMMA decrease by (0.05) compere to pure PMMA films and addition energy gap appear equal to (4.1 e v). It was found that the absorption coefficient, extinction coeff

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Materials Today: Proceedings
The influence of water-gypsum ratio on the properties of national gypsum (Jοss) for various additives
...Show More Authors

View Publication
Scopus (13)
Crossref (7)
Scopus Crossref