Companies compete greatly with each other today, so they need to focus on innovation to develop their products and make them competitive. Lean product development is the ideal way to develop product, foster innovation, maximize value, and reduce time. Set-Based Concurrent Engineering (SBCE) is an approved lean product improvement mechanism that builds on the creation of a number of alternative designs at the subsystem level. These designs are simultaneously improved and tested, and the weaker choices are removed gradually until the optimum solution is reached finally. SBCE implementations have been extensively performed in the automotive industry and there are a few case studies in the aerospace industry. This research describe the use of trade-off curve as a lean tool to support SBCE process model in CONGA project, using NASA simulation software version 1.7c and CONGA demonstration program (DEMO program) to help designers and engineers to extract the design solution where it exists according to the customer requirement and to extract alternative nearest solutions from the previous project that meet customer requirement to achieve low noise engine at an aerospace company and also extract the infeasible region where the designers cannot make any prototype in this region before manufacturing process begin, that will lead to reducing rework, time and cost.
This paper deals with an analytical study of the flow of an incompressible generalized Burgers’ fluid (GBF) in an annular pipe. We discussed in this problem the flow induced by an impulsive pressure gradient and compare the results with flow due to a constant pressure gradient. Analytic solutions for velocity is earned by using discrete Laplace transform (DLT) of the sequential fractional derivatives (FD) and finite Hankel transform (FHT). The influences of different parameters are analyzed on a velocity distribution characteristics and a comparison between two cases is also presented, and discussed in details. Eventually, the figures are plotted to exhibit these effects.
This research aims to identify the role of external environment factors on the quality of educational services, from the academic point of view, where the distribution of a questionnaire to a random sample of (100) university professors, and then analyzing a model, and test the validity of this model using structural modeling (SEM) (Structural Equation Modeling).
And then test the relationships between variables using the software of Statistical Package for Social Sciences (SPSS V.18), the research found a number of conclusions, the most important conclusion is: the external environment factors has significant impact on the quality of educational services.
ABSTRACT
This study aimed to choose top stocks through technical analysis tools specially the indicator called (ratio of William index), and test the ability of technical analysis tools in building a portfolio of shares efficient in comparison with the market portfolio. These one technical tools were used for building one portfolios in 21 companies on specific preview conditions and choose 10 companies for the period from (March 2015) to (June 2017). Applied results of the research showed that Portfolio yield for companies selected according to the ratio of William index indicator (0.0406) that
... Show Morehe current research aims at showing the correlation and effect of the internal environment analysis in the quality of health service in AL_Elwiya Maternity Teaching Hospital, researcher depended on the integral method in the "analytical descriptive method" for the study of the relation between the main variables and the sub-variables throughout data collection required by the theme of this study, a case study" in tackling the data and information related to the financial aspects of the internal environment.
The problem of the study was manifested in the essential question, that is (is there internal struc
... Show MoreThe effective insulation design of the stress grading (SG) system in form-wound stator coils is essential for preventing partial discharges and excessive heat generation under pulse-width modulation excitation. This paper proposes a method to find the optimal insulation design of the SG system aimed at reducing the dielectric and thermal stresses in the machine coil. The non-uniform transmission line model is used to predict the voltage propagation along the overhang, SG, and slot regions considering the variation in the physical properties of the insulation layers. The machine coil parameters for different insulation materials are calculated by using the finite element method. Two optimization algorithms, fmincon and particle swarm optimiz
... Show MoreThe research dealt with the topic ' the aesthetics of design shape of interior spaces for the syndicate of physicians' as it reflects visions evolving to the level of tasting and positive interpretation for the space of work to be on a high design level.The research consisting of four chapters as follow; The first chapter examined the problem of the research contracted in the following question: Have the design shapes any role in achieving and showing the aesthetic side for the syndicate of physicians? so the goal of the research was showing the aesthetics of design shape of interior spaces for the syndicate of physicians, The chapter also included the objective spatial and temporal limits of research .Finally the terms were specified. T
... Show MoreThe change in the size of the droplets during the pesticide application process could have a negative impact on the percentage of drift or the losses of pesticides to the environment. One of the factors that could affect the droplet size produced from a single nozzle is the internal design of the nozzle itself, in addition to the wear of the nozzle orifice as a result of the usage time. In this research, three types of nozzles with different internal designs were used (Turbo TeeJet (TT), Turbo TwinJet (TTj 6011003), and Drift Guard (DG 11003)). The nozzles were subjected to an accelerated wear test for one hundred hours, and different droplet size parameters (Dv 0.1, Dv 0.5, Dv 0.9),