Preferred Language
Articles
/
alkej-679
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different levels of Maximum Voluntary Contraction (MVC) (10-100%). In order to analyze the collected EMG and force data, the mean absolute value of each trial is calculated followed by a calculation of the average of the 3 trials for each grip for each subject across the different MVC levels utilized in the study. Then, the mean and the standard deviation (SD) across all participants (3 males and 2 females) are calculated for FCR, FDS and APB muscles with multiple % MVC, i.e 10, 30, 50, 70 % MVC for each gesture. The results showed that APB muscle has the highest mean EMG activity across all grips, followed by FCR muscle. Furthermore, the grip with the thumb and middle fingers is the grip with the highest EMG activity for 10-70% MVC than the power grip. As for the 100% MVC, thumb and middle fingers grip achieved the highest EMG activity for APB muscle, while the power grip has the highest EMG activity for both FCR and FDS muscles.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Oct 21 2020
Journal Name
British Journal Of Cancer
Epigenome-wide analysis reveals functional modulators of drug sensitivity and post-treatment survival in chronic lymphocytic leukaemia
...Show More Authors
Abstract<sec> <title>Background

Chronic lymphocytic leukaemia (CLL) patients display a highly variable clinical course, with progressive acquisition of drug resistance. We sought to identify aberrant epigenetic traits that are enriched following exposure to treatment that could impact patient response to therapy.

Methods

Epigenome-wide analysis of DNA methylation was performed for 20 patients at two timepoints during treatment. The prognostic significance of differentially methylated regions (DMRs) was assessed in independent cohorts of 139 and 1

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Aug 30 2015
Journal Name
Statistical Analysis Of The Relations Between Api,specific Gravity And Sulfur Content In The Universal Crude Oil
Statistical Analysis of the Relations between API, Specific Gravity and Sulfur Content in the Universal Crude Oil
...Show More Authors

Publication Date
Wed Jan 17 2018
Journal Name
Journal Of Engineering And Applied Sciences
PREPARATION, CHARACTERIZATION AND THERMAL ANALYSIS OF POLYMERIC BLEND NANOCOMPOSITES BASED ON PVA-PVPPEGDOPED WITH ZINC OXIDE NANOPARTICLES
...Show More Authors

Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Dentistry
In-vitro adhesive and interfacial analysis of a phosphorylated resin polyalkenoate cement bonded to dental hard tissues.
...Show More Authors

Objectives: To assess the performance of a novel resin-modified glass-ionomer cement (pRMGIC) bonded to various tooth tissues after two-time intervals. Methods: 192 sound human molars were randomly assigned to 3 groups (n = 64): sound enamel, demineralised enamel, sound dentine. Sixty-four teeth with natural carious lesions including caries-affected dentine (CAD) were selected. All substrates were prepared, conditioned and restored with pRMGIC (30% ethylene glycol methacrylate phosphate (EGMP, experimental), Fuji II LC (control), Fuji IX, and Filtek™ Supreme with Scotchbond ™ Universal Adhesive. Shear bond strength (SBS) was determined after 24 h and three months storage in SBF at 37C. The debonded surfaces were examined using stereomi

... Show More
View Publication
Scopus (7)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Physics: Conference Series
Data Processing, Storage, and Analysis: Applying Computational Procedures to the Case of a Falling Weight Deflectomer (FWD)
...Show More Authors

In the field of civil engineering, the adoption and use of Falling Weight Deflectometers (FWDs) is seen as a response to the ever changing and technology-driven world. Specifically, FWDs refer to devices that aid in evaluating the physical properties of a pavement. This paper has assessed the concepts of data processing, storage, and analysis via FWDs. The device has been found to play an important role in enabling the operators and field practitioners to understand vertical deflection responses upon subjecting pavements to impulse loads. In turn, the resultant data and its analysis outcomes lead to the backcalculation of the state of stiffness, with initial analyses of the deflection bowl occurring in conjunction with the measured or assum

... Show More
Scopus Crossref
Publication Date
Tue Jul 01 2008
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
THE STUDY OF MINERALOGICAL AND MICROFACIES ANALYSIS SHIRANISH FORMATION WELL (KH-6) ANSAB AREA IN SOUTHERN IRAQ
...Show More Authors

The study of Shiranish Formation rocks in southern part of Iraq at Ansab area well (KH-6)
were carried out. The formation is tongued with tayarat formation, which bounded from top
and bottom, the upper tongue at thickness 49m. and tongued at depth (476-525m.) the lower
tongue at thickness 4m. tongued at (541-537m.).
The rocks of this formation were divided into three sedimentary microfacies:
1- Dolomitized formininferal Wackestone facies.
2- Dolomitized formininferal Mudstone facies.
3- Dolostone facies.
34 slides were investigated depending on mineralogical, compositional and biological
processes and compared diagenesis which reflect open marine shelf at lower part of formation
(F.Z.2) (S.M.F.8), but at the

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Reliability Analysis of Multibit Error Correcting Coding and Comparison to Hamming Product Code for On-Chip Interconnect
...Show More Authors

Error control schemes became a necessity in network-on-chip (NoC) to improve reliability as the on-chip interconnect errors increase with the continuous shrinking of geometry. Accordingly, many researchers are trying to present multi-bit error correction coding schemes that perform a high error correction capability with the simplest design possible to minimize area and power consumption. A recent work, Multi-bit Error Correcting Coding with Reduced Link Bandwidth (MECCRLB), showed a huge reduction in area and power consumption compared to a well-known scheme, namely, Hamming product code (HPC) with Type-II HARQ. Moreover, the authors showed that the proposed scheme can correct 11 random errors which is considered a high

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Journal Of Engineering
Analysis of Traditional and Fuzzy Quality Control Charts to Improve Short-Run Production in the Manufacturing Industry
...Show More Authors

Quality control charts are limited to controlling one characteristic of a production process, and it needs a large amount of data to determine control limits to control the process. Another limitation of the traditional control chart is that it doesn’t deal with the vague data environment. The fuzzy control charts work with the uncertainty that exists in the data. Also, the fuzzy control charts investigate the random variations found between the samples. In modern industries, productivity is often of different designs and a small volume that depends on the market need for demand (short-run production) implemented in the same type of machines to the production units. In such cases, it is difficult to determine the contr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Advances In Structural Engineering
Experimental and FE analysis of composite RC beams with encased pultruded GFRP I-beam under static loads
...Show More Authors

Encasing glass fiber reinforced polymer (GFRP) beam with reinforced concrete (RC) improves stability, prevents buckling of the web, and enhances the fire resistance efficiency. This paper provides experimental and numerical investigations on the flexural performance of RC specimens composite with encased pultruded GFRP I-sections. The effect of using shear studs to improve the composite interaction between the GFRP beam and concrete was explored. Three specimens were tested under three-point loading. The deformations, strains in the GFRP beams, and slippages between the GFRP beams and concrete were recorded. The embedded GFRP beam enhanced the peak loads by 65% and 51% for the composite specimens with and without shear connectors,

... Show More
View Publication
Crossref (18)
Clarivate Crossref