Electrical Discharge Machining (EDM) is a non-traditional cutting technique for metals removing which is relied upon the basic fact that negligible tool force is produced during the machining process. Also, electrical discharge machining is used in manufacturing very hard materials that are electrically conductive. Regarding the electrical discharge machining procedure, the most significant factor of the cutting parameter is the surface roughness (Ra). Conventional try and error method is time consuming as well as high cost. The purpose of the present research is to develop a mathematical model using response graph modeling (RGM). The impact of various parameters such as (current, pulsation on time and pulsation off time) are studied on the surface roughness in the present research. 27 samples were run by using CNC-EDM machine which used for cutting steel 304 with dielectric solution of gas oil by supplied DC current values (10, 20, and 30A). Voltage of (140V) uses to cut 1.7mm thickness of the steel and use the copper electrode. The result from this work is useful to be implemented in industry to reduce the time and cost of Ra prediction. It is observed from response table and response graph that the applied current and pulse on time have the most influence parameters of surface roughness while pulse off time has less influence parameter on it. The supreme and least surface roughness, which is achieved from all the 27 experiments is (4.02 and 2.12µm), respectively. The qualitative assessment reveals that the surface roughness increases as the applied current and pulse on time increases
In this study, a cholera model with asymptomatic carriers was examined. A Holling type-II functional response function was used to describe disease transmission. For analyzing the dynamical behavior of cholera disease, a fractional-order model was developed. First, the positivity and boundedness of the system's solutions were established. The local stability of the equilibrium points was also analyzed. Second, a Lyapunov function was used to construct the global asymptotic stability of the system for both endemic and disease-free equilibrium points. Finally, numerical simulations and sensitivity analysis were carried out using matlab software to demonstrate the accuracy and validate the obtained results.
In this work, porous silicon gas sensor hs been fabricated on n-type crystalline silicon (c-Si) wafers of (100) orientation denoted by n-PS using electrochemical etching (ECE) process at etching time 10 min and etching current density 40 mA/cm2. Deposition of the catalyst (Cu) is done by immersing porous silicon (PS) layer in solution consists of 3ml from (Cu) chloride with 4ml (HF) and 12ml (ethanol) and 1 ml (H2O2). The structural, morphological and gas sensing behavior of porous silicon has been studied. The formation of nanostructured silicon is confirmed by using X-ray diffraction (XRD) measurement as well as it shows the formation of an oxide silicon layer due to chemical reaction. Atomic force microscope for PS illustrates that the p
... Show MoreThe results of analyzing BVRI CCD photometry of the spiral galaxies NGC 7339, NGC 7537, and NGC 7541 are presented using the observations acquired with the 1.88m Kottamia telescope (Egypt). The overall structure of the galaxies is analyzed together with isophotal contour maps. The surface brightness profiles of the galaxies are decomposed to bulge and disk components by fitting a de Vaucouleurs law for the bulge and an exponential law for the disk to obtain photometric parameters for each component. The corrected total and absolute magnitudes and integrated color are also obtained and found to be close to the published values. The radial profiles of ellipticity, major-axis position angle, and color are also obtained and discussed.
Abstract: Tin oxide thin films were deposited by direct current (DC) reactive sputtering at gas pressures of 0.015 mbar – 0.15 mbar. The crystalline structure and surface morphology of the prepared SnO2 films were introduced by X-ray diffraction (XRD) and atomic force microscopy (AFM). These films showed preferred orientation in the (110) plane. Due to AFM micrographs, the grain size increased non-uniformly as the working gas pressure increased.
Background: Measuring the concentration of hepatitis B surface antigen (HbsAg) in HBV patients can be determined with immunoassay techniques. This study aimed to measure the HbsAg titers in chronic HBV patients and to assess its correlation with patients' ages, gender, and with the levels of liver enzymes and total serum bilirubin. Materials and Method: Fifty-eight chronic hepatitis B infected patients were enrolled in this study. Age and gender of the patients were recorded. HbsAg concentration was tested with automated Immunoanalyzer. The patients were also tested for ALT, AST, ALP, and TSB by automated chemistry analyzer. Results: All the chronic HBV patients have positive HBsAg titers above the negative cutoff (0.05U/L) with mea