Preferred Language
Articles
/
alkej-648
Study the Effect of Residence Time Parameters on Thermal Cracking Extract Phase Lubricating Oil
...Show More Authors

This work studies with produce of light fuel fractions of gasoline, kerosene and gas oil from treatment of residual matter that will be obtained from the solvent extraction process as by product from refined lubricate to improve oil viscosity index in any petroleum refinery. The percentage of this byproduct is approximately 10% according to all feed (crude oil) in the petroleum refinery process. The objective of this research is to study the effect of the residence time parameter on the thermal cracking process of the byproduct feed at a constant temperature, (400 °C). The first step of this treatment is the thermal cracking of this byproduct material by a constructed batch reactor occupied with control device at a selective range of residence time (duration of the reaction) 30, 45, 60 and 75 minutes respectively at a constant temperature (400 °C). The conversion of this byproduct by thermal cracking process reaches 90% for all these residence times. The second step for this study is distillation this cracked extract liquid by atmospheric distillation device, for these various residence times according to the ASTM-D86 method, to obtain light fuel fractions of gasoline, kerosene and gas oil,in volume percentages  15, 75 and 0 for residence time 30, 5, 60 and 25, for residence time 45, 5, 10, 75, for residence time 60 and (10, 60 and 20) for residence time 75, which separates according to its boiling point. The major physical and chemical properties for feed (extract phase) and cracking extract liquid with its light fuel fractions were experimentally calculated and the results refer to acceptable properties compared with other standard property.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Formation Evaluation for Nasiriyah Oil Field Based on The Non-Conventional Techniques
...Show More Authors

The unconventional techniques called “the quick look techniques”, have been developed to present well log data calculations, so that they may be scanned easily to identify the zones that warrant a more detailed analysis, these techniques have been generated by service companies at the well site which are among the useful, they provide the elements of information needed for making decisions quickly when time is of essence. The techniques used in this paper are:

  • Apparent resistivity Rwa
  • Rxo /Rt

   The above two methods had been used to evaluate Nasiriyah oil field formations (well-NS-3) to discover the hydrocarbon bearing formations. A compu

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Restriction Shape On Laminar Natural Convection Heat Transfer In A Vertical Circular Tube
...Show More Authors

Natural convection heat transfer is experimentally investigated for laminar air flow in a vertical circular tube by using the boundary condition of constant wall heat flux in the ranges of (RaL) from (1.1*109) to (4.7*109). The experimental set-up was designed for determining the effect of different types of restrictions placed at entry of heated tube in bottom position, on the surface temperature distribution and on the local and average heat transfer coefficients. The apparatus was made with an electrically heated cylinder of a length (900mm) and diameter (30mm). The entry restrictions were included a circular tube of same diameter as the heated cylinder but with lengths of (60cm, 120cm), sharp-edge and

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Charge Stratification and Fuel/Air Ratio Effect on the Efficiency of (ICADE) I. C. Engine Cycle
...Show More Authors

The Isolated Combustion and Diluted Expansion (ICADE) internal combustion engine cycle combines the advantages of constant volume combustion of the Otto cycle with the high compression ratio of the Diesel cycle.   This work studies the effect of isolated air mass (charge stratification) on the efficiency of the cycle; the analysis shows that the decrease of isolated air mass will increase the efficiency of the cycle and the large dilution air mass will quench all NOx forming reactions and reduce unburned hydrocarbons. Furthermore, the effect of Fuel / Air ratio on the efficiency shows that the increase of Fuel / Air ratio will increase efficiency of the cycle.

View Publication Preview PDF
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Solid Properties on Axial Liquid Dispersion in Bubble Column
...Show More Authors

Experiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2020
Journal Name
Alexandria Engineering Journal
Impact of development on Baghdad’s urban microclimate and human thermal comfort
...Show More Authors

View Publication
Scopus (49)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Theoretical and Experimental Evaluation of Particle size Effect of Iron , Cobalt ,and Nickel Powders Suspended in Al Dura oil on XRF Intensities
...Show More Authors

Iron , Cobalt , and Nickel powders with different particle sizes were subjected to sieving and He-Ne laser system to determine the particle size . 1wt% from each powders was blended carefully with 99wt% from Iraqi oil . Microscopic examination were carried for all samples to reveal the particle size distribution . A Siemens type SRS sequential wavelength dispersive(WDS) X-ray spectrometer was used to analyze all samples , and the XRF intensity were determined experimentally and theoretically for all suspended samples , Good agreement between theoretical and experimental results were found .

View Publication Preview PDF
Crossref
Publication Date
Sun Jan 19 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Effect flexibility of the Strategic human resources in improvement operational performance: "Survey study of views of a sample of managers, engineers and technicians in the Baghdad south 2/Station directorate of Electricity"
...Show More Authors

The research attempts to diagnose the level of the effect of human resources flexibility (employees skills flexibility, employees behaviors flexibility, and human resource practice flexibility) in the south al-rusafa directorate of a power  station one of the formations and the Ministry of Electricity, and impact of a range of variables related to the performance operational, namely, (efficiency, effectiveness)recognizing the importance of the subjects studied,& because of the importance of expected results of the field under consideration,researcher selected a sample of size (121) engineers and technicians of workers in the directorate. Was my hypotheses the major search of a relationship and impact between human resources flex

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Design and Implementation of Single-Phase Boost PFC Converter
...Show More Authors

In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Apr 11 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE MICROBIAL CONTAMINATION OF BROKEN AND CRACKED COMMERCIAL TABLE EGG IN BAGHDAD MARKETS AND ITS ECONOMIC EFFECT: STUDY THE MICROBIAL CONTAMINATION OF BROKEN AND CRACKED COMMERCIAL TABLE EGG IN BAGHDAD MARKETS AND ITS ECONOMIC EFFECT
...Show More Authors

The aim of this novel native study was to determine the microbial contamination of broken and cracked imported commercial table egg in Baghdad markets and its economic effect. A total of 21510 commercial chicken table eggs were checked and surveyed from retail markets in different popular regions of Baghdad city during a year period from January 3rd to December 28th of 2018 and its microbial contamination were studied. Results revealed that significant differences (P<0.01) were appeared in the studied microbial counts during months of the study and significant differences (P<0.01) in the average counts between broken and cracked eggs and sound (not bro

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 12 2023
Journal Name
Energies
Finite Time Disturbance Observer Based on Air Conditioning System Control Scheme
...Show More Authors

A novel robust finite time disturbance observer (RFTDO) based on an independent output-finite time composite control (FTCC) scheme is proposed for an air conditioning-system temperature and humidity regulation. The variable air volume (VAV) of the system is represented by two first-order mathematical models for the temperature and humidity dynamics. In the temperature loop dynamics, a RFTDO temperature (RFTDO-T) and an FTCC temperature (FTCC-T) are designed to estimate and reject the lumped disturbances of the temperature subsystem. In the humidity loop, a robust output of the FTCC humidity (FTCC-H) and RFTDO humidity (RFTDO-H) are also designed to estimate and reject the lumped disturbances of the humidity subsystem. Based on Lyapunov theo

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref