Preferred Language
Articles
/
alkej-640
Wearable Detection Systems for Epileptic Seizure: A review
...Show More Authors

The seizure epilepsy is risky because it happens randomly and leads to death in some cases. The standard epileptic seizures monitoring system involves video/EEG (electro-encephalography), which bothers the patient, as EEG electrodes are attached to the patient’s head.

Seriously, helping or alerting the patient before the seizure is one of the issue that attracts the researchers and designers attention. So that there are spectrums of portable seizure detection systems available in markets which are based on non-EEG signal.

The aim of this article is to provide a literature survey for the latest articles that cover many issues in the field of designing portable real-time seizure detection that includes the use of multiple body signals, new algorithm methods, and detection devices that are commercially available.

As a result, the reviewing process shows that there are many research articles that have covered wearable seizure detection systems that based on body signals. The more effective monitoring and detection seizure system is the system that uses multi-body signals, is highly comfortable and has low power consumption.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Global Pharma Technology
Detection of HBME-1 and galectin-3 by immunohistochemistry in follicular lesions
...Show More Authors

The main problem established by a discovery of a thyroid nodule is to discriminate between a benign and malignant lesion. Differential diagnosis between follicular thyroid cancer (FTC) and benign follicular thyroid adenoma (FTA) is a great challenge for even an experienced pathologist and requires special effort. A developing number of some encouraging IHC markers for the differential diagnosis of thyroid lesions have emerged, including, Hector Battifora mesothelial (HBME-1) and galectin-3 (Gal-3). There was significant positive correlation between Galectin-3 and HBME-1 in follicular carcinoma and follicular variant of papillary carcinoma (r= 0.380, P= 0.041) and (r= 0.315, P=0.047) respectively. There was no significant correlation between

... Show More
Scopus
Publication Date
Sun Jan 01 2017
Journal Name
Spe
SPE-188966-MS: Drilling problems detection in Basrah oil fields using smartphones
...Show More Authors

Scopus (1)
Scopus
Publication Date
Mon Dec 02 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability
Effect of thickness variation CdO/PSi thin films on detection of radiation
...Show More Authors

CdO films were deposited on substrates from glass, Silicon and Porous silicon by thermal chemical spray pyrolysis technique with different thicknesses (130 and 438.46) nm. Measurements of X-ray diffraction of CdO thin film proved that the structure of the Polycrystalline is cubic lattice, and its crystallite size is located within nano scale range where the perfect orientation is (200). The results show that the surface’s roughness and the root mean square increased with increasing the thickness of prepared films. The UV-Visible measurements show that the CdO films with different thicknesses possess an allowed direct transition with band gap (4) eV. AFM measurement revealed that the silicon porosity located in nano range. Cadmium oxide f

... Show More
Scopus (2)
Scopus
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Detection of Nutrients and Major Ions at Al Muthanna Storage Site Soil
...Show More Authors

In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesi

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraq Journal Of Market Research And Consumer Protection
DETECTION OF HEAVY METALS POLLUTION INTYPES OF MILK SAMPLES IN BAGHDAD MARKETS
...Show More Authors

View Publication
Crossref
Publication Date
Mon Apr 19 2010
Journal Name
Computer And Information Science
Quantitative Detection of Left Ventricular Wall Motion Abnormality by Two-Dimensional Echocardiography
...Show More Authors

Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jul 10 2024
Journal Name
The Open Neuroimaging Journal
The Efficacy of Bedside Chest Ultrasound in the Detection of Traumatic Pneumothorax
...Show More Authors
Background

Chest X-rays have long been used to diagnose pneumothorax. In trauma patients, chest ultrasonography combined with chest CT may be a safer, faster, and more accurate approach. This could lead to better and quicker management of traumatic pneumothorax, as well as enhanced patient safety and clinical results.

Aim

The purpose of this study was to assess the efficacy and utility of bedside US chest in identifying traumatic pneumothorax and also its capacity to estimate the extent of the lesion in comparison to the gold standard modality chest computed tomography.

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Wed Feb 03 2016
Journal Name
Nanoscience And Nanotechnology
Fabrication of Functionalize Reduce Graphene Oxide and Its Application in Ampicillin Detection
...Show More Authors

Graphene oxide (GO) was prepared from graphite (GT) with Hammer method, the GO was reduced with hydrazine hydrate to produce a reduced graphene oxide (RGO). The RGO was reacted with thiocarbohydrazide (TCH) to functionalize the RGO with 4-amino-3-symbol-1h-1, 2, 4-triazol-5 (4H) –thion group and to obtain (RGOT). All the prepared nanomaterial and the product of the functionalization RGOT were characterized with Fourier transformer infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) analysis. RGOT mixed with ultrasonic device at different pH values of phosphate buffer solution (PBS), the mixture used to modifying a screen printed carbon electrodes SPCE and with cyclic voltammetry the sensitivity of selectivity of the new modifying elect

... Show More
Preview PDF