Preferred Language
Articles
/
alkej-629
Parametric study of thermal behavior of thrust chamber cooling channels
...Show More Authors

A numerical investigation is adopted for two dimensional thermal analysis of rocket thrust chamber wall (RL10), employing finite difference model with iterative scheme (implemented under relaxation factor of 0.9 for convergence) to compute temperature distribution within thrust chamber  wall (which is composed of Nickel and Copper layers). The analysis is conducted for different boundary conditions: only convection boundary conditions then combined radiation, convection boundary conditions also for  different aspect ratio (AR) of cooling channel. The results show that Utilizing cooling channels of high aspect ratio leads to decrease in temperature variation across thrust chamber wall, while no effects on heat transferred to the coolant is indicated. The radiation has a considerable effect on the  computed wall temperature values.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Alexandria Engineering Journal
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
...Show More Authors

View Publication
Scopus (25)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Surface Roughness on Thermohydrodynamic Performance in Misaligned Journal Bearings
...Show More Authors

     In this work an approach has been developed to investigate the influence of surface roughness on thermohydrodynamic performance in aligned and misaligned journal bearings by considering an average flow model and deriving the shear flow factor for various roughness configurations, similar to the pressure flow factor. An average Reynolds equation for rough surfaces is defined in term of pressure and shear flow factors, which can be obtained by numerical flow simulation, though the use of measured or numerically generated rough surfaces. Reynolds, heat conduction and energy equations are solved simultaneously by using a suitable numerical technique (Finite Difference Method) to obtain the pressure and temperature di

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Impact of Public Spending on Kaldor's Square Variables in Iraq for the period (2005-2016).
...Show More Authors

The paper aims to measure and analysis the impact Public Spending on Iraq economy (Kaldor Variables).

 (variables of the magic square Kaldor) and them in after 2003.

The paper adopted econometric Methods to test the stationarity of the Variables under consideration. For the period (2005-2016) by using multiple regression and estimation the Impulse response function (IRF), by adopting Eviews 10 program.

The results of Impulse response function for the following five-years after the period under consideration reflexes that public expenditure (PEX) was fluctuating between positive and negative in all the variables of the research and this shows the fragility of the performance of fiscal policy in Iraq.

T

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Investigations on the Impact of Using Elliptic Groynes on the Flow in Open Channels
...Show More Authors

This paper presents a numerical simulation of the flow around elliptic groynes by using CFD ‎software. The flow was simulated in a flume with 4m long, 0.4m wide, ‎and 0.175m ‎high ‎‎with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow ‎‎inlet with a ‎constant the Groyne height of 10cm and a 1cm thickness, and the ‎width of Groynes equals ‎7cm‎. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of ‎0.0057‎m3/sec. The CFD ‎model showed a good ability to simulate the flow ‎around ‎Groynes with ‎ good accuracy. The results of ‎CFD software showed that when using double elliptic Groy

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 22 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimizing the Parameters of Hot-wire CNC Machine to Enhance the Cutting of Plastic Foam
...Show More Authors

     Hot-wire cutting is one of the important, non-traditional thermomechanical way to cut polymer, usually expanded foam and extruded foam, in low volume manufacturing. The study and analysis of Hot-Wire cutting parameters play an important role to enhance the quality and accuracy of the process and products. The effects on the surface have been investigated by using experimental tests designed according to the Taguchi orthogonal array (OA). In this study, four parameters with five levels for each parameter have been used: [temperature of wire (A) (100, 120, 130, 150, 160) °C], [diameter of wire (B) (0.3,0.4,0.5,0.7,0.8) mm], [velocity of cutting (C) (200, 300,400,500,600) mm/min], [and density of foam (D) (0.01,0.0

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Encyclopedia Of Smart Materials
Modeling Behavior of Magnetorheological Fluids
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Transient Behavior of Straight Fins
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Nov 26 2018
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Different Percentages of Natural (Orange Peels and Date Seeds) and Industrial Materials (Carbon and Silica) on the Mechanical and Thermal Properties of Polymeric Reinforced Composites
...Show More Authors

Mechanical and thermal properties of composites, consisted of unsaturated polyester resin, reinforced by different kinds of natural materials (Orange peels and Date seeds) and industrial materials (carbon and silica) with particle size 98 µm were studied. Various weight ratios, 5, 10, and 15 wt. % of natural and industrial materials have been infused into polyester. Tensile, three-point bending and thermal conductivity tests were conducted for the unfilled polyester, natural and industrial composite to identify the weight ratio effect on the properties of materials. The results indicated that when the weight ratio for polyester with date seeds increased from 10% to 15%, the maximum Young’s modulus decreased by 54%. When the weight rat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Studying the Effect of Volume Fraction of Glass Fibers on the Thermal Conductivity of the Polymer Composite Materials
...Show More Authors

In this study the effect of fiber volume fraction of the glass fiber on the thermal conductivity of the polymer composite material was studied. Different fiber volume fraction of glass fibers were used (3%, 6%, 9%, 12%, and 15%). Specimens were made from polyester which reinforced with glass fibers .The fibers had two arrangements according to the direction of the thermal flow. In the first arrangement the fibers were parallel to the direction of the thermal flow, while the second arrangement was perpendicular; Lee's disk method was used for testing the specimens. The experimental results proved that the values of the thermal conductivity of the specimens was higher when the fibers arranged in parallel direction than that when the fibers

... Show More
View Publication Preview PDF