This research involves study effect of chloride ions in concentration range (0.01 – 0.50 mol.dm-3) on the corrosion behavior of Al-Zn alloy in basic media of 1x10-3 mol.dm-3 NaOH at pH=11 and four different temperatures in the range (298-313 K). Cathodic and anodic Tafel slopes (bc &ba) and transfer coefficients (αc & αa) were calculated and the results interprets according to the variation of the rate – determining steps. The results also indicate that the chloride ions are bonded chemically in the interface as an initial step of formation of different mixed oxohydroxy – and chloro complexes. Polarization resistance (Rp) is calculates and interprets the different polarization behavior because of addition of chloride ions to the basic media.
To achieve the goals, the researcher followed the design of equal and independent groups of partial control and post-test . The research has chosen the Institute of Fine Arts in the area Almansour area as deliberate sample where three sections of students have been chosen and the number of students is (69) students. The researcher conducted equivalence in the variables (age, and IQ , and the overall rate for grade III). in diagnostic phase, (21) concepts of alternative image out of (46) concepts have been identified in addition to the goals of formulation of acquisition concepts according to the three processes (definition, discrimination and application). Achievement test has been
... Show MoreObjective: To evaluate the effectiveness of educational program on female students’ knowledge toward premenstrual syndrome.
Methodology: A quasi-experimental design study conducing on (140) student purposely in four secondary schools at Al-sadder city (70) student for study group and (70) for control group. The prevalence of PMS selected through American College of Obstetricians and Gynecologists (ACOG) (2015) criterias to select PMS students before program. The education program were set in four steps, the first step (pre-test) is to assess the knowledge , before the implementation of the program, the second step is implementing the program, following two steps post-test I and II between each test two weeks. Validity is determined
The research includes the synthesis and identification of the mixed ligands complexes of M+2ions in general composition[M(Asn)2(SMX)] Where L- Aspargine (C4H8N2O3)symbolized (AsnH) as a primary ligand and Sulfamethoxazole(C10H11N3O3S) symbolized (SMX) as a secondary ligand. The ligands and the metal chlorides were brought in to reaction at room temperature in(v/v) ethanol /water as solvent containing NaOH. The reaction required the following [(metal: 2(Na+Asn-): (SMX)] molar ratios with M(II) ions, Where: M(II)=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II). The UV–Vis and magnetic moment data revealed an octahedral geometry around M(II), The conductivity data show a non-electrolytic nature of the complexes. The antimicrobial a
... Show MoreThe inhibitive effect of imidazol on the dissolution of Zn in (1M) HCl has been studied. The inhibion effect of imidazol ,protection efficiency and the corrosion rate of Zn in (1M) HCl were investigated at various concentrations (1x 10-3 – 5x10-3) M and tempearture range (285-328) K. The corrosion inhibitive of Zn by imidazol was studied using weight loss measurement and analytical titration of the amounts of dissolved zinc in acidic solution in presence and absent of imidazol. It was observed that imidazol led to protection efficiency reached to (88.93)% when (10)mM imidazol concentration was used. A linear relationship came true between (C/?) and (C); where (?) is the coverage of Zn surface by imidazol which could be obtained from
... Show MoreThe corrosion of low carbon steel boiler tubes in demi water had been investigated. The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperatures. For low carbon steel experiments, the temperature was taken in three levels (125, 175, and 215°C) under about 27 bar pressure and 1500 rpm in autoclave. Using weight loss technique, the corrosion rate ranges from (85 to 789 gmd) for low carbon steel boiler tubes.
This research aims to knowledge of the scope of applying the international specification of which is regarded to occupational health and safety management system (OHSAS 18001) second edition for year 2007 by The AL-Mammon Factory / The General Company For Vegetable Oils Industry in order to diagnosis the gap between specification requirements and reality by using the checklist made based upon the items of the specification, after translating the English copy into Arabic. The results of the research and analysis that occupational health and safety management system in comparison to the specification requirements in all of its main items, which was (%22.26) applied and documented partly, this refer to the existence of great gap (%7
... Show MoreThe study aimed to identify the effect of Total Quality Management on enhancing competitiveness through the opinions of employees of the front- rows of customer service in local Palestinian banks, the researcher adopted an analytical descriptive method through developing a special questionnaire to accomplish the study’s objectives and answer its questions. The study involved all the Palestinian local banks, with their scattered branches in West Bank. The study sample consisted of 3470 executive employees for banking services out of 4753 employees, in the rate of 73%, and the study sample reached (485) employees who were randomly selected working in the front -rows to provide services in the local Palestinian banks during the ye
... Show MoreThe paper considers the main types of corrosion taking into account the direction of corrosion processes. The main parameters of metal building structures corrosion and factors that have a significant influence on these parameters are taken into account, which can influence the increase of such structures longevity. One of the main factors of corrosion rate determining is the humidity of air and dust deposited on surface from atmosphere at production emissions.
This work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power
... Show MoreBreak in the bond and its impact on the difference of scholars