Preferred Language
Articles
/
alkej-605
Extraction of Phenol From Industrial Water Using Different Solvents
...Show More Authors

The analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.

                The ternary equilibrium diagrams and tie-lines data for systems containing Water-Phenol-Benzene, Water-Phenol-Chloroform, Water-Phenol-iso-Butyl Acetate, Water-Phenol-Butanol, Water-Phenol-Ethyl Methyl Keton and Water-Phenol-Toluene, were determined at 303 K and atmospheric pressure.

                The capacity and selectivity of these organic solvents in each of these systems were determined from the tie-lines data. The capacity of the isobutyle acetate was found to be the highest among the other solvents, and its selectivity was also the highest. Similar results also were obtained for the ethyl methyl keton but gave less capacity and selectivity as compared to the isobutyle acetate. It can be concluded that both isobutyle acetate and ethyl methyl keton are good solvents for extraction of phenol from industrial water.

                The liquid-liquid equilibrium data of ternary systems were correlated to the NRTL, UNIQUAC and UNIFAC models of activity coefficient to determine their adjustable parameters. The standard deviations from experimental compositions were calculated. Results show that the correlation may be greatly improved by applying the NRTL model with the regression criteria based on minimizing the experimental and calculating distribution coefficients SK to give an average value of the root mean square deviation about 1.436 % and in terms of the average errors in the distribution ratio for all tie-lines about 10.776 %.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of operation conditions on Catalytic Oxidation of Phenol in Aqueous Solution
...Show More Authors

This work was conducted to study the oxidation of phenol in aqueous solution using copper based catalyst with zinc as promoter and different carrier, i.e. γ-Alumina and silica. These catalysts were prepared by impregnation method.
The effect of catalyst composition, pH (5.6-9), phenol to catalyst concentration ratio (2-0.5), air feed rate (30-50) ml/s, stirring speed (400-800) rpm, and temperature (80-100) °C were examined in order to find the best conditions for phenol conversion.
The best operating conditions which lead to maximum phenol conversion (73.1%) are : 7.5 pH, 4/6 phenol to catalyst concentration, 40 ml/s air feed rate, 600 rpm stirring speed, and 100 °C reaction temperature. The reaction involved an induction period

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Computers, Materials & Continua
Industrial Recycling Process of Batteries for EVs
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2013
Journal Name
Isesco Journal Of Science And Technology
Effect of Solvents on the Dipole Moments and Fluorescence Quantum Yield of Rhodamine Dyes
...Show More Authors

Abstract: This study aims to investigate the effects of solvents of various polarities on the electronic absorption and fluorescence spectra of RhB and Rh6G. The singlet‐state excited dipole moments (me) and ground state dipole moments (mg) were estimated from the equations of Bakshiev -Kawski and Chamma‐ Viallet using the variation of Stokes shift along with the solvent’s dielectric constant (e) and refractive indexes (n). The observed singlet‐state excited dipole moments were found to be larger than the ground‐state ones. Moreover, the obtained fluorescence quantum yield values were influenced by the environment of the fluorescing molecule. Consequently, the concentration of the dye solution, excited singlet state absorption and

... Show More
Preview PDF
Publication Date
Wed May 30 2018
Journal Name
Journal Of Engineering
Numerical Modeling of Water Movement from Buried Vertical Ceramic Pipes through Soils
...Show More Authors

The problem of water scarcity is becoming common in many parts of the world, to overcome part of this problem proper management of water and an efficient irrigation system are needed.  Irrigation with a buried vertical ceramic pipe is known as a very effective in the management of irrigation water.  The two- dimensional transient flow of water from a buried vertical ceramic pipe through homogenous porous media is simulated numerically using the HYDRUS/2D software.  Different values of pipe lengths and hydraulic conductivity were selected.  In addition, different values of initial volumetric soil water content were assumed in this simulation as initial conditions.  Different value

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Apr 07 2025
Journal Name
Al-nahrain Journal For Engineering Sciences
Design of Reverse Osmosis Water Treatment Unit Using Lanxess Lewaplus2
...Show More Authors

Basrah is the richest town and the economic capital of Iraq. It suffers from lack of drinking water. This project is a dream to supply drinking water to Basrah citizens within WHO standards. Water should pass sedimentation and filtration stages before interring reverse osmosis unit. The design is carried out using lewaplus2 software. Several parameters should be selected in the design step membrane type, number of stages, number per element in each stage, and the recovery percentage. An optimization is carried out using Minitab ver. 18 for the acceptable limit of TDS and minimum cost and it was found that the optimum conditions were 52% for first stage, the numbers of vessels are 20 for both the first and second stage. In addition,

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Treatment of Sulfate in Sand by Using Magnetic Water Process
...Show More Authors

One of the most important problems in concrete production in Iraq and other country is the high sulfate content in sand that led to damage of concrete and hence reduces its compressive strength and may leads to cracking due to internal sulfate attack and delay ettringite formation. The magnetic water treatment process is adopted in this study. Many samples with different SO3 content are treated with magnetic water (12, 8, 4 and 2)L that needed for each 1kg of sand with the magnetic intensity (9000 and 5000) Gaus. The magnetic water needed is reduced with less SO3 content in sand. The ACI 211.1-91 concrete mix design was used in this research with slump range (75- 100) mm and the specified compressive strength (35MPa). The compressive streng

... Show More
Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Physics: Conference Series
Measurement of uranium concentration in the water samples collected from the areas surrounding in Al-Tuwaitha nuclear site using the CR-39 detector
...Show More Authors

Abstract. In this research, the uranium concentration in (16) water samples collected from some agricultural areas surrounded with AlTuwitha nuclear site in Baghdad-Iraq was measured by using a CR-39 detector. The concentration of uranium in this study was from (0.6 ± 0.33mg/l) to (2.51 ± 0.49 mg/l), and the weighted average for the concentrations (1.262 ± 0.402 mg/l). The results showed it is a concentration of uranium level in water samples studied is higher than the allowed limit recommended by WHO and ICRP.

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Oct 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Ions release from fixed orthodontic appliance in two different mouthwashes
...Show More Authors

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Middle-east Journal Of Scientific Research
Question Classification Using Different Approach: A Whole Review
...Show More Authors

Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Possibility of glucose level assessment using the blood of gingival probing and dental socket after tooth extraction
...Show More Authors

Background: The association between diabetes and inflammatory dental diseases had been studied extensively for more than 50 years. A large evidence base suggests that diabetes is associated with an increased prevalence, extent and severity of gingivitis and periodontitis and loss of teeth. Many patients do not aware that they are diabetic.Objectives:The aim of the current study was to assess a fast, non-invasive, safe procedure to screen for diabetes and its severity in dental clinics and to assess the change in blood glucose level before and after tooth extraction during periodontalResults: there were no significant differences between the blood samples collected before tooth extraction from finger puncture method (FPB) and the gingival

... Show More
View Publication Preview PDF