Preferred Language
Articles
/
alkej-602
MINIATURE TWO-FINGERED ROBOT HAND DRIVEN BY MUSCLE WIRES ACTUATORS
...Show More Authors

In this research, a modified artificial hand with direct control has been designed using electrical artificial muscle wires that receive direct sensory impulses through human hand instead of using the mechanical action to open and close this artificial hand. Each finger is designed as a chain and its movements achieved through the conventional arrangement control of the electrical muscles wires. The results indicate that it is possible to design an artificial hand using electrical muscle wire for control it with high accuracy.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Design of Robotic Arm Control System Mimics Human Arm Motion
...Show More Authors

This paper presents a control system to make the robotic hand mimic human hand motion in real time and offline mode. The human hand tracking system is a wearable sensing arm (potentiometers) used to determine the position in space and to sense the grasping task of human hand. The maskable sensing arm was designed with same geometrical arrangement of robotic hand that needs to be controlled. The control software of a robot was implemented using Visual Basic and supported with graphical user interface (GUI). The control algorithm depends on joint to joint mapping method to match between the motions at each joint of portable sensing arm with corresponding joint of a robot in order to make the robot mimic the motion.

View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Conditions by 810 nm Diode Laser
...Show More Authors

When laser light incident on biological tissue, it is either reflected from the
surface of the tissue (e.g. the skin) or scattered inside the tissue or absorbed .The laser light will be
absorbed by water, hemoglobin and melanin. Absorption is also highly dependent on wave-length of
laser radiation. The absorbed light is converted into kinetic energy leading to laser effect that when
appropriately applied can produce reaction ranging from incision, vaporization to coagulation. Aim of
the study: To evaluate the efficiency of diode Laser 810 ± 20nm in treatment of oral lesions. Methods:
6 patients (2 females and 4 males) with different oral lesions were treated in the hospital of specialized
surgeries by the use of dio

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
The Numerical Technique Based on Shifted Jacobi-Gauss-Lobatto Polynomials for Solving Two Dimensional Multi-Space Fractional Bioheat Equations
...Show More Authors

This article deals with the approximate algorithm for two dimensional multi-space fractional bioheat equations (M-SFBHE). The application of the collection method will be expanding for presenting a numerical technique for solving M-SFBHE based on “shifted Jacobi-Gauss-Labatto polynomials” (SJ-GL-Ps) in the matrix form. The Caputo formula has been utilized to approximate the fractional derivative and to demonstrate its usefulness and accuracy, the proposed methodology was applied in two examples. The numerical results revealed that the used approach is very effective and gives high accuracy and good convergence.

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2004
Journal Name
Pmj-iraqi Postgraduate Medical Journal
The role of circulating phagocytic cells in muscle regeneration
...Show More Authors

Results: it was found that labelled cells participated in the formation of myotubes, which formed mature muscle fibers, and possibly new satellite cells. The results of this experiment may eventually revolutionized therapeutic procedures for some form of muscle diseases

Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Pharmacological Research
Resveratrol-mediated attenuation of superantigen-driven acute respiratory distress syndrome is mediated by microbiota in the lungs and gut
...Show More Authors

View Publication Preview PDF
Scopus (37)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Education For Pure Science- University Of Thi-qar
Dorsal Hand Vein Image Recognition: A Review
...Show More Authors

Subcutaneous vascularization has become a new solution for identification management over the past few years. Systems based on dorsal hand veins are particularly promising for high-security settings. The dorsal hand vein recognition system comprises the following steps: acquiring images from the database and preprocessing them, locating the region of interest, and extracting and recognizing information from the dorsal hand vein pattern. This paper reviewed several techniques for obtaining the dorsal hand vein area and identifying a person. Therefore, this study just provides a comprehensive review of existing previous theories. This model aims to offer the improvement in the accuracy rate of the system that was shown in previous studies and

... Show More
Publication Date
Sun Jan 02 2011
Journal Name
Al-khwarizmi Engineering Journal
Biomechanical Concept Design of Artificial Human Hand
...Show More Authors

This work is focused on the design parameters and activity of artificial human finger for seven grips. At first, obtained the ideal kinematics of human fingers motion by analyzing the grips video which were recorded using a single digital camera recorder fitted on a tripod in sagital plane while the hand is moving. Special motion analysis software (Dartfish) the finger joint angles were studied using the video recording. Then the seven grips were modeled using static torque analysis, which calculates the amount of torque applied on the fingers joint grip depending on the results of the kinematic analysis. The last step of the work was to design the actuator (Muscle Wire) of artificial finger for the seven grips in a simple design approac

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Surgical Case Reports
A rare variant of mirror hand deformity
...Show More Authors

Congenital hand and forearm anomalies pose a unique challenge in plastic and pediatric surgery. We present a case report of an 8- months-old girl with a congenital left sided hand and forearm anomaly, provisionally diagnosed as atypical left mirror hand anomaly. Classically there is absence of radius and duplication of ulna; however, our case had normal radius and ulna and a hand with seven digits arranged in two groups. We did a surgery which involved a ray amputation of the finger ulnar to the most radial digit, aiming to preserve an adequate first web space to reconstruct the thumb. The result of the surgical treatment in both functional and cosmetic aspects was, in authors’ opinion, good.

Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Warts Treatment by 810 nm Diode Laser Irradiation: A New Approach
...Show More Authors

The present work was done in an attempt to build systematic procedures for treating warts by 810 nm diode laser regarding dose parameters, application parameters and laser safety. The study was done in Al- Kindy Teaching Hospital in Baghdad, Iraq during the period from 1st October 2003 till 1st April 2004. Fifteen patients completed the treatment and they were followed for the period of 3 months. Recalcitrant and extensive warts were selected for the study. Patients were randomly divided into 3 groups to be treated by different laser powers 9, 12 and 15 W, power density of 286 W/cm2, 381W/cm2, 477 W/cm2 pulse duration of 0.2 s, interval of 0.2 s and repeated pulses were used. The mode of application was either circular or radial. Pain oc

... Show More
View Publication Preview PDF