This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagnosis identification.
We prepared polythiophene (PTH) with single wall carbon nanotube (SWCNT) nanocomposite thin films for Nitrogen dioxide (NO2) gas sensing applications. Thin films were synthesized via electrochemical polymerization method onto (Indium tin oxide) ITO coated glass substrate of thiophene monomer with magnesium perchlorate and different concentration from SWCNT (0.012 and 0.016) % in the presence130mL of Acetonitrile used. X-ray diffraction (XRD), Field Emission Scanning Electron microscopy (FE-SEM), Atomic Force Microscope (AFM) and Fourier Transform Infrared Spectroscopy (FT-IR) were used to characterized these nanocomposite thin films. The response of these nanocomposite for NO2 gas was evaluated via monitoring the change
... Show MoreBackground: The Apgar score is calculated based on the five features: heart rate, reflexes, color, muscle tone, and respiratory effort. Each element is scored from 0 to 2, with a total probable score of 10 at 1 minute and 5 minute. Aim: To study the influence of gestational diabetes mellitus (GDM) and diabetes mellitus on APGAR score in neonate. Materials and methods: The samples were studied from Department of Obstetrics and Gynaecology in Al-Imamain Al-Kadhimiyain (AS) Medical city, Baghdad Teaching Hospital and Al-Karkh Maternity Hospital in the period between 1 December 2016 and 1 may 2017, after obtaining the approval from Iraqi Ministry of Health. A total of 102 neonates were included in this study which includes 34 neonates of mother
... Show MoreThe research discusses the issue of attribution to the verb, because the Arab scholars are unanimous in preventing attribution of the verb, because it is always informed of it, and does not inform about it, but this consensus violates the linguistic use. The research discusses this matter.
Background: Semen contamination is a detrimental factor in decreasing fertility. Seasonal changes may affect the contamination, too. Objectives: This study was designed to detect semen contamination in ovine and caprine during different seasons. Methods: Six fully mature male sheep and goats were subjected to electro-ejaculator collection twice monthly from February 1, 2022, to January 31, 2023 (Spring, February 1, 2022-April 30, 2022; Summer, May 1, 2022, July 31, 2022; Autumn August 1, 2022, October 31, 2022; Winter November 1, 2022, January 31, 2023), for studying the seasonal effect. A total of 288 semen samples were collected from both species (36 samples from each per season). All samples were subjected to bacterial isolatio
... Show MoreDiamond-like carbon (DLC) homogeneous thin films were deposited from cyclohexane (Ccyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (C 6H12 ) liquid by using a plasma jet system which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with al
... Show MoreThis research concerns study the crack growth in the wall of pipes made of low carbon steel under the impact load and using the effect of hygrothermal (rate of moisture 50% and 50℃ temperature). The environmental conditions were controlled using high accuracy digital control with sensors. The pipe have a crack already. The test was performed and on two type of specimens, one have length of 100cm and other have length 50cm. The results were, when the humidity was applied to the pipe, the crack would enhance to growth (i.e. the number of cycles needed to growth the crack will reduce). In addition, when the temperature was increase the number of cycles needed to growth the crack are reduced because the effect of heat on the mechanical pro
... Show MoreThis contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res
... Show MoreTest method was developed radioimmunotherapy to appoint in two groups of patients infected with a uterine tumor Great conditions in tumor tissue benign and malignant Ddh teacher radioactive iodine isotope
In this study, the quality assurance of the linear accelerator available at the Baghdad Center for Radiation Therapy and Nuclear Medicine was verified using Star Track and Perspex. The study was established from August to December 2018. This study showed that there was an acceptable variation in the dose output of the linear accelerator. This variation was ±2% and it was within the permissible range according to the recommendations of the manufacturer of the accelerator (Elkta).