The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without tracking system (case 2). The experimental results showed that the average solar radiation falling on the PTSC prototype in the two cases during the same time was 854 and 701 watt/m2, respectively, which means an increase in the solar radiation about 21.8 % when using tracking system. It was found that the average useful heat gain output of solar collector was equal to (376.2, 252.6 watt) for the two cases, respectively, so there was an increase of about 48.9 % when using the tracking system. Also, the average thermal efficiency of the PTSC was found to be (20.7, 26.5 %) for the two cases, respectively, which means an increase in the average efficiency by 28% with use of tracking system compared to the fixed case.
The study included evaluation of cell surface charge and hydrophobicity of Escherichia coli, Klebsilla aerogenes, Proteus spp, Bacillus cereus, Staphylococcus epidermidis, Staphylococcus aureus(1) and Staphylococcus aureus(2) were determined by hydrocarbon adherence and hydrophobic interaction chromatography. The results showed that the negative charge of cell surface of gram negative bacteria was much higher than on gram positive once when these bacteria were grown on nutrient agar at 37 c for 18 h . E.coli was more negative charged than Klebsilla aerogenes and Proteus spp. The hydrophobicity of gram positive bacteria was much
... Show MorePurpose A diagnosis of tuberculosis (TB) of the head and neck has been a dilemma for clinicians, because the clinical and pathologic features tend to mimic different pathologies. Our study aimed to identify the demographic, clinical, and pathologic features of head and neck TB to help healthcare providers in the early detection of the disease. Materials and Methods We performed a retrospective analysis using the medical archives at the pathology laboratory. Twenty-one patients with a clinical and pathologic diagnosis of head and neck TB were identified from 2010 to 2019. Results The age distribution was broad, with 28.5% of the patients younger than 15 years old. Seven patients had oral TB, with the most common sites affected the labial ves
... Show MoreObjective: To assess the nurses-midwives' knowledge and practices regarding the management of second stage
of labor and to find out the association between their knowledge and practices and socio-demographic
characteristics and working years and experience.
Methodology: A descriptive study was carried out from March 22nd
, 2008 through 30th June, 2008. A purposive
sample of (75) Nurse-Midwives which was selected from (6) hospitals. A questionnaire was comprised of two
parts: (socio-demographic characteristics and the assessment tool for Nurse-Midwives' knowledge and health
practices performed by them). The questionnaire validity was determined by experts and its reliability was
determined through a pilot study. Th
Molar conductivity of different concentrations of thymine and adenosine in water , sodium acetate and ammonium chloride solution at different temperatures , 283. 15-323.15 K has been determined from direct conductivity measurements , examination of aqueous mixture of thymine and adenosine with Onsager equation reveal deviation from linearity at high concentration .This deviation was explained in term of molecular interaction . Ostwald dilution law also examined with the above mixtures lead to calculation of limiting molar conductivities and dissociation constants of both nucleic acid in water , sodium acetate and ammonium chloride. The agreement between the values obtained for Onsager equation and Ostwald law was reaso
... Show MoreThe main target of the current study is to investigate the microbial content and mineral contaminants of the imported meat available in the city of Baghdad and to ensure that it is free from harmful bacteria, safe and it compliances with the Iraqi standard specifications. Some trace mineral elements such as (Iron, Copper, Lead, and Cadmium) were also estimated, where 10 brands of these meats were collected. Bacteriological tests were carried out which included (total bacterial count,
Zerumbone is a well-known compound having anti-cancer, anti-ulcer, anti-inflammatory and anti-hyperglycemic effects. During its use for the disease treatment, the membrane of erythrocyte can be affected by consumption of this bioactive compound. The current study was the first report of investigation of the hemolytic activities on human erythrocytes and cytotoxic profile of zerumbone. The toxicity of zerumbone on human erythrocytes was determined by in vitro hemolytic assay. Brine shrimp lethality assay was used to evaluate the cytotoxic effect of zerumbone at concentrations 10, 100 and 1000 μg/mL. The human erythrocyte test showed no significant toxicity at low concentrations, whereas hemolytic effect was amplified up to 17.5
... Show MoreThe reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,
... Show More