Hard Chromium Electroplating and Improvement the Properties by the Thermo Chemical Treatments (Solid Carburizing) of Low Carbon Steel
...Show More Authors

In this research the hard chromium electroplating process, which is one of the common methods of overlay coating was used, by using chromium acid as source of chromium and sulphuric acid as catalyst since the ratio between chromic acid and sulphuric acid is (100 : 1) consequently. Plating process was made by applying current of density (40 Amp / dm2) and the range of solution temperature was (50 – 55oC) with different time periods (1-5 hr). A  low carbon steel type (Ck15) was used as substrate for hard chromium electroplating. Solid carburization was carried out for hard chromium plating specimen at temperature (925oC) with time duration (2 hr) to be followed with quenching and tempering. The phase analysis was conducted by using X– ray diffraction. The examination results show that the chromium carbides in plating layer were (Cr23C6, Cr7C3). The microhardness of hard chromium plating specimen was measured, and the results show that the high hardness was about (907HV). After solid carburization the hardness values increase and the results show that the higher hardness for chromium plating layer on low carbon steel surface was (1276 HV).                                                      

      Wear apparatus type (Pin on Disc) was used to study dry sliding  wear properties of low carbon steel (As received) and hard chromium  plating specimens and solid carburized. The effect of applied normal load on wear rate was studied with weighting method using five normal loads (5, 10, 15, 20, 25 N) at constant sliding speed (2.198 m / sec). The results reveal that the wear rate increases with the increasing of applied normal load. A good improvement in wear resistance was noticed for hard chromium plating specimens as compared with substrate specimen. It was also seen that, the improvement in wear resistance was (94%) as compared with substrate metal when carburizing treatment is carried out on hard chromium plating specimens.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Integration of Dissolved Analysis and Total Quality Management to reduce costs and improve product quality
...Show More Authors

there is a need to use the teardown Technique in a various fields and different motives and used often by economic units as a technique to help other techniques for example, used by some economic units for the analysis of other economic units of products in order to work on the development of products and look for opportunities to improve product quality and avoid product errors competitor or reduce its costs, in addition to the services provided by quality control is used ISO 17025 integration with unassembled analysis to adjust the quality of the product by comparing the pieces produced with designed models that are also the product as a whole compared with the original design

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 25 2019
Journal Name
The Eurasia Proceedings Of Science Technology Engineering And Mathematics
Impact of the Chemical Mutagenesis on Biomass and Productivity of some Micro Green Algae
...Show More Authors

The Eurasia Proceedings of Science Technology Engineering and Mathematics | Volume: 6

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Biochem. Cell. Arch.
ANATOMICAL AND CHEMICAL STUDY OF ALTHEAE OFFICINALIS L. SPREAD IN THE NORTH OF IRAQ
...Show More Authors

Scopus (2)
Scopus
Publication Date
Tue May 02 2023
Journal Name
Journal Of Optoelectronics And Advanced Materials
Preparation of samarium doped-PMMA composite by casting method to evaluate the optical properties and potential applications
...Show More Authors

Samarium ions (Sm +3), a rare-earth element, have a significant optical emission within the visible spectrum. PMMA samples, mixed with different ratios of SmCl3.6H2O, were prepared via the casting method. The composite was tested using UV-visible, photoluminescence and thermogravimetric analysis (TGA). The FTIR spectrometry of PMMA samples showed some changes, including variation in band intensity, location, and width. Mixed with samarium decreases the intensity of the CO and CH2 stretching bands and band position. A new band appeared corresponding to ionic bonds between samarium cations with negative branches in the polymer. These variations indicate complex links between the Sm +3 ion and oxygen in the ether group. The optical absorption

... Show More
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
The Structure and Optical Properties of Ag doped CdO Thin Film Prepared by Pulse Laser Deposition (PLD)
...Show More Authors

At a temperature of 300 K, a prepared thin film of Ag doped with different ratios of CdO (0.1, 0.3, 0.5) % were observed using pulse laser deposition (PLD). The laser, an Nd:YAG in ?=1064 nm, used a pulse, constant energy of 600 mJ ,with a repetition rate of 6 Hz and 400 pulses. The effect of CdO on the structural and optical properties of these films was studied. The structural tests showed that these films are of a polycrystalline structure with a preferred orientation in the (002) direction for Ag. The grain size is positively correlated with the concentration of CdO. The optical properties of the Ag :CdO thin film we observed included transmittance, absorption coefficient, and the energy gap in the wavelength range of 300-1100

... Show More
View Publication Preview PDF
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Int. J. Nanoelectronics And Materials
Comparsion of the physical properties for CdS and CdS doped PVA thin films prepared by spray pyrolysis
...Show More Authors

Preview PDF
Publication Date
Sun May 28 2023
Journal Name
Journal Of Inorganic And Organometallic Polymers And Materials
Improving the Dielectric, Thermal, and Electrical Properties of Poly (Methyl Methacrylate)/Hydroxyapatite Blends by Incorporating Graphene Nanoplatelets
...Show More Authors

In this article, the casting method was used to prepare poly(methyl methacrylate)/hydroxyapatite (PMMA/HA) nanocomposite films incorporated with different contents (0.5, 1, and 1.5 wt%) of graphene nanoplatelets (Gnp). The chemical properties and surface morphology of the PMMA/HA blend and PMMA/HA/Gnp nanocomposite were characterized using FTIR, and SEM analysis. Besides, the thermal conductivity, dielectric and electrical properties at (1–107 Hz) of the PMMA/HA blend and PMMA/HA/Gnp composites were investigated. The structural analysis showed that the synthesized composites had a low agglomerated state, with multiple wrinkles of graphene flakes in the PMMA/HA blend. The thermal conductivity was improved by more than 35-fold its value for

... Show More
View Publication
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Latest Trends In Engineering And Technology
Study the effect of number of nozzle on optical and structural properties of sno2 films grown by (apcvd)
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Studying The Effect of The Type of Substrate on The Structural, Morphology and Optical Properties of TiO2 Thin Films Prepared by RF Magnetron Sputtering
...Show More Authors

View Publication
Crossref (12)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
COMPUTER-BASED ECG SIGNAL ANALYSIS AND MONITORING SYSTEM
...Show More Authors

This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagno

... Show More
View Publication Preview PDF