Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy
...Show More Authors

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the solar radiation.  Experimental data was measured to study the performance of the system. The proposed system was compared with the conventional one. Results show that the COP of the proposed system was higher than the COP of the conventional system by 10 %. In addition, the controlled system saved an electricity of 11.2 %. The optimum opening valve ratio fluctuated between 0.3 and 0.4 when the heater power was 500 W.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Results In Physics
Optimization of dye extraction from Cordyline fruticosa via response surface methodology to produce a natural sensitizer for dye-sensitized solar cells
...Show More Authors

View Publication
Scopus (28)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The impact of quality costs in improving the quality of health services
...Show More Authors

Improving the quality of health services in the health sector is an important and necessary matter that must be taken care of and improved, and this study seeks to demonstrate the role of quality costs in improving the quality of health services and achieving a high level of quality to satisfy the beneficiaries and to provide health services of good quality, and the research concluded that the main point of service provision Good health is the costs of prevention and evaluation (costs of quality conformity) and attention to it, and that technical competition contributes greatly to the development of the level of quality, as well as the use of health and medical staff with competent expertise, and that the costs of internal failure and th

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The role of judicial accounting in improving the quality of financial reports
...Show More Authors

     The quality of the financial reports depends on set of accounting standards ,most of wich have been studied for the purpose of ascertaining the relationship between the standard used and the quality of the financial reports that contribute significantly to improving the financial performance of the institution, Research aims to detect the relationship between forensic accounting and the quality of financial reports, The research included a key hypothesis that forensic accountability could be applied to improve the quality of financial reporting, A sample of gentlemen (external auditors, tax assessors, judges, university professors, shareholders)  (45

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Evergreen
Development, Validation, and Performance Evaluation of An Air-Driven Free-Piston Linear Expander Numerical Model
...Show More Authors

View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Journal Of Engineering
Energy, Exergy and Anergy Analysis of Vertical Split Air Conditioner Under experimental ON-OFF Cycling
...Show More Authors

A time series analysis can help to observe the behavior of the system and specify the system faults. In addition, it also helps to explain the various energy flows in the system and further aid in reducing the thermodynamic losses. The intelligent supervisory LabVIEW software can monitor the incoming data from the system by using Arduino microcontroller and calculates the important parameters. Energy, exergy, and anergy analysis present in this paper to investigate the system performance as well as its components. To accomplish this, a 4-ton vertical split air conditioner based on vapor compression refrigeration cycle charged with refrigerant R-22 was modified for experimental analysis. The results showed that during 540

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 31 2017
Journal Name
Journal Of Engineering
Experimental and Numerical Simulation of an Airlift Pump with Conventional and Modified Air Injection Device
...Show More Authors

The effect of air injection device on the performance of airlift pump used for water pumping has been studied numerically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90  (for conventional) to 22.5  (for modified). Continuity and Navier-Stokes equations in turbulent regime with an appropriate two-phase flow model (VOF) and turbulent model (   ) in two dimensions axisymmetry flow were formulated and solved by using the known package FLUENT version (14.5). The numerical and experimental investiga

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Assessment of Air Pollution around Durra Refinery (Baghdad) from Emission NO2 Gas at April Month
...Show More Authors

Nitrogen dioxide NO2 is one of the most dangerous contaminant in the air, its toxic gas that cause disturbing respiratory effects, most of it emitted from industrial sources especially from the stack of power plants and oil refineries. In this study Gaussian equations modelled by Matlab program to state the effect of pollutant NO2 gas on area around Durra refinery, this program also evaluate some elements such as wind and stability and its effect on stacks height. Data used in this study is the amount of fuel oil and fuel gas burn inside refinery at a year 2017. Hourly April month data chosen as a case study because it’s unsteady month. After evaluate emission rate of the all fuel and calculate exit velocity from

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Jan 29 2021
Journal Name
Research Journal Of Pharmacy And Technologythis Link Is Disabled.
Exploration of a new fluoride resistance gene (Fram gene) in oral streptococcus mutans maw
...Show More Authors

Publication Date
Fri Feb 01 2019
Journal Name
Iraqi Journal Of Information & Communications Technology
Evaluation of DDoS attacks Detection in a New Intrusion Dataset Based on Classification Algorithms
...Show More Authors

Intrusion detection system is an imperative role in increasing security and decreasing the harm of the computer security system and information system when using of network. It observes different events in a network or system to decide occurring an intrusion or not and it is used to make strategic decision, security purposes and analyzing directions. This paper describes host based intrusion detection system architecture for DDoS attack, which intelligently detects the intrusion periodically and dynamically by evaluating the intruder group respective to the present node with its neighbors. We analyze a dependable dataset named CICIDS 2017 that contains benign and DDoS attack network flows, which meets certifiable criteria and is ope

... Show More
View Publication Preview PDF
Crossref (22)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
A New Two Derivative FSAL Runge-Kutta Method of Order Five in Four Stages
...Show More Authors

A new efficient Two Derivative Runge-Kutta method (TDRK) of order five is developed for the numerical solution of the special first order ordinary differential equations (ODEs). The new method is derived using the property of First Same As Last (FSAL). We analyzed the stability of our method. The numerical results are presented to illustrate the efficiency of the new method in comparison with some well-known RK methods.

View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref