Simulation of free convection heat transfer in a square enclosure induced by heated thin plate is represented numerically. All the enclosure walls have constant temperature lower than the plate’s temperature. The flow is assumed to be two-dimensional. The discretized equations were solved stream function, vorticity, and energy equations by finite difference method using explicit technique and Successive Over- Relaxation method. The study was performed for different values of Rayleigh number ranging from 103 to 105 for different angle position of heated thin plate(0°, 45°, 90°). Air was chosen as a working fluid (Pr = 0.71). Aspect ratio of center of plate to the parallel left wall A2 take a constant and is equal to 0.5. The effect of the angle position of the heated thin plate on heat transfer and flow were addressed. With the increase of Rayleigh number heat transfer rate increased in both vertical and horizontal position of the plate. For the vertical situation (γ=90°) of thin plate, heat transfer becomes more enhanced than for the horizontal situation (γ=0°) and the inclined situation (γ=45°) especially when the value of aspect ratio A1 is equal to 0.25.
Abstract
This paper discusses the essence of the developmental process in auditing firms and offices at the world today. This process is focused on how to adopt the audit concepts which is based on Information and Communication Technology (ICT), including the Continuous Auditing (CA) in particular. The purpose of this paper is to design a practical model for the adoption of CA and its requirements according to the Technology Acceptance Model (TAM). This model will serve as a road map for manage the change and development in the Iraqi auditing firms and offices. The paper uses the analytical approach in reaching to the target results. We design the logical and systematic relations between the nine variable
... Show MoreThis paper investigate a sensorless speed control of a separately excited dc motor fed from a buck type dc-dc converter. The control system is designed in digital technique by using a two dimension look-up table. The performance of the drive system was evaluated by digital simulation using Simulink toolbox of Matlab.
This research presents a statistical study of radiation generated from communication towers in the Nineveh Plain region Baghdeda. The intensity of radiation energy was measured at 10 meters away from the communication tower in different locations, using a (1PC XH-901 Dosimeter/ Personal Dose Alarm / Radiation Detector, dosage rate: 0.01 μSv/h to 150μSv/h) to measure the amount of radiation at various times. Energy densities were measured and compared with standard limits provided by other authorities, such as the International Committee for Radiation Protection. Results were analyzed using SPSS version 26 to implement the data. The results show that the means of the radiation levels measured at all the zones do not statistically differ
... Show MoreGlobal warming has had considerable effects on vital ecosystems, which has also been caused by increased temperatures and CO2 that follow changes in different abiotic factors, which poses threats to mangrove forests environment. This research was conducted to examine the physiological and morphological characteristics of the Rhizophora apiculata mangrove regarding higher air temperature for the variety of tree species that respond to climate change. Seedlings were cultivated for three months in regulated growth chambers with three varying temperatures of 38°C, 21°C under CO2 at 450 ppm, and ambient CO2 concentration i.e., 450 ± 20 ppm under average temperature at 28°C as the control condition
... Show MoreEconomics / University of Mosul
Abstract
The spread of the phenomenon of excessive buying in our society, especially for cosmetics, and at the same time increase the marketing deception by the organizations to take quick profit 'and accordingly was identified the problem of research in several questions, including:
Is there a significant effect of consumption culture on marketing deception? &n
... Show MoreThe Audit evedances represent the reconciliation tools between the Financial data shown on financial statements, and the level of satisfaction level of the Auditor about these statements. According that, the Auditor try to achieve the highest quantity of These evidances, and the most satisfactive of it…, but that will be so hard sometimes, when the internal controlling system is not good, and when the Auditor had some satisfied evidences, but not sharp… So, this research comes to inspect the relation between the quantity, and the level of satisfaction, and argument to prove that evidences gives. This research assumes that getting enough evidences leads to reduce faults, improves the auditing operation, and avoids risks. The research
... Show MoreThe paper aims to measure and analysis the impact Public Spending on Iraq economy (Kaldor Variables).
(variables of the magic square Kaldor) and them in after 2003.
The paper adopted econometric Methods to test the stationarity of the Variables under consideration. For the period (2005-2016) by using multiple regression and estimation the Impulse response function (IRF), by adopting Eviews 10 program.
The results of Impulse response function for the following five-years after the period under consideration reflexes that public expenditure (PEX) was fluctuating between positive and negative in all the variables of the research and this shows the fragility of the performance of fiscal policy in Iraq.
T
... Show MoreThe effects of using aqueous nanofluids containing covalently functionalized graphene nanoplatelets with triethanolamine (TEA-GNPs) as novel working fluids on the thermal performance of a flat-plate solar collector (FPSC) have been investigated. Water-based nanofluids with weight concentrations of 0.025%, 0.05%, 0.075%, and 0.1% of TEA-GNPs with specific surface areas of 300, 500, and 750 m2/g were prepared. An experimental setup was designed and built and a simulation program using MATLAB was developed. Experimental tests were performed using inlet fluid temperatures of 30, 40, and 50 °C; flow rates of 0.6, 1.0, and 1.4 kg/min; and heat flux intensities of 600, 800, and 1000 W/m2. The FPSC’s efficiency increased as the flow rate and hea
... Show More