pH-Control Problems of Wastewater Treatment Plants
...Show More Authors

Experimental investigations have been carried out to investigate the pH-control problems of industrial electroplating wastewater treatment plants. The accurate and sensitive PID control system could treat most problem and disturbances in the normal operation of the water treatment. However, conventional treatment was replaced by proprietary treatment agent called a QUASIL which was found to be more effective for a wide range of pH.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Problems of Heavy Oil Transportation in Pipelines And Reduction of High Viscosity
...Show More Authors

Drag has long been identified as the main reason for the loss of energy in fluid transmission like pipelines and other similar transportation channels. The main contributor to this drag is the viscosity as well as friction against the pipe walls, which will results in more pumping power consumption.

   The aim in this study was first to understand the role of additives in the viscosity reduction and secondly to evaluate the drag reduction efficiency when blending with different solvents.

   This research investigated flow increase (%FI) in heavy oil at different flow rates (2 to 10 m3/hr) in two pipes (0.0381 m & 0.0508 m) ID By using different additives (toluene and naphtha) with different concent

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Removal of Zinc ions from industrial wastewater with wool fibers
...Show More Authors

In this research, the efficiency of low-cost unmodified wool fibers were used to remove zinc ion from industrial wastewater. Removal of zinc ion was achieved at 99.52% by using simple wool column. The experiment was carried out under varying conditions of (2h) contact time, metal ion concentration (50mg/l), wool fibers quantity to treated water (70g/l), pH(7) & acid concentration (0.05M). The aim of this method is to use a high sensitive, available & cheep natural material which applied successfully for industrial wastewater& synthetic water, where zinc ion concentration was reduced from (14.6mg/l) to (0.07mg/l) & consequently the hazardous effect of contamination was minimized.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu May 25 2023
Journal Name
Asian Journal Of Water, Environment And Pollution
Microbial Simultaneous Eradication from Wastewater of Sulphate and Heavy Metals
...Show More Authors

Hazardous materials, heavy metals, and organic toxins released into the environment have caused considerable harm to microbes, plants, animals, and humans. Wastewater is one of the most contaminated ecosystems due to heavy metals emitted mostly by human activity. Bioremediation of wastewater is an ecologically acceptable and cost-effective method of removing heavy metals from sewage; the general purpose of this study is to analyse the dependability of anaerobic sludge biomass in removing sulfur compounds and heavy metals from waste water. The anaerobic sludge biomass evaluated in this work was taken from a wastewater treatment plant (WWTP) in Al-Rustumiya, Baghdad, and grown in the mineral medium for anaerobic growth. In serum bottl

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Flotation of Chromium Ions from Simulated Wastewater Using Air Microbubbles
...Show More Authors

   A microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/mi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 23 2020
Journal Name
Iraqi Journal Of Agricultural Sciences
PHYTOREMEDIATION OF SYNTHETIC WASTEWATER CONTAINING COPPER BY USING NATIVE PLANT
...Show More Authors

This study was aimed to assess the efficiency of N.oleander to remove heavy metals such as Copper (Cu) from wastewater. A toxicity test was conducted outdoor for 65-day to estimate the ability of N.oleander to tolerate Cu in synthetic wastewater. Based on a previous range-finding test, five concentrations were used in this test (0, 50, 100, 300, 510 mg/l). The results showed that maximum values of removal efficiency was found 99.9% on day-49 for the treatment 50 mg/l. Minimum removal efficiency was 94% day-65 for the treatment of 510 mg/l. Water concentration was within the permissible limits of river conservation and were 0.164 at day-35 for the 50 mg/l treatment, decreased thereafter until the end of the observation, and 0.12 at d

... Show More
Crossref
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Stability testing of time series data for CT Large industrial establishments in Iraq
...Show More Authors

Abstract: -
The concept of joint integration of important concepts in macroeconomic application, the idea of ​​cointegration is due to the Granger (1981), and he explained it in detail in Granger and Engle in Econometrica (1987). The introduction of the joint analysis of integration in econometrics in the mid-eighties of the last century, is one of the most important developments in the experimental method for modeling, and the advantage is simply the account and use it only needs to familiarize them selves with ordinary least squares.

Cointegration seen relations equilibrium time series in the long run, even if it contained all the sequences on t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Waterpipe Smoking Effect on Clinical Periodontal Parameters, Salivary Flow Rate and Salivary pH in Chronic ‎Periodontitis Patient
...Show More Authors

Background: Waterpipe tobacco smoking has become common especially among young people, Waterpipe smoking misconcepted as a safer mean of smoking, so in this study we will highlight the effect of Waterpipe smoking ‎on periodontal and oral health.‎ Materials and method. The selected ‎‎‎100 male subjects of 30-40 years, ‎categorized into 4 groups (each group ‎‎25 subject): Waterpipe smoker ‎with ‎healthy periodontium, ‎Waterpipe smoker ‎‎with chronic periodontitis, Non-‎‎smoker ‎with healthy periodontium and Non-smoker ‎with chronic periodontitis. Whole ‎unstimulated ‎saliva was collected. Clinical measurements: plaque ‎index

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
دور حوكمة الشركات في معالجة الاختلالات الهيكلية في سوق العراق للاوراق المالية
...Show More Authors

تعد حوكمة الشركات Governance  من المواضيع التي تهم العديد من الباحثين والمنظمات المهنية والدولية في فروع عديدة من المعرفة ، حيث يتضمن مفهوم حوكمة الشركات الاطار الذي يتم من خلاله وضع أهداف الشركات والمتمثله في حماية مصالح حملة الاسهم والاخرين من أصحاب المصلحه ، وتعظيم أداء الشركات وتقليل المخاطر وتحسين فرص الوصول الى أسواق رأس المال.  وان احد اسباب ظهور حوكمة الشركات هو وجود عدد من الاختلالات الهيكلية في ا

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 29 2021
Journal Name
Al-khwarizmi Engineering Journal
Robust Computed Torque Control for Uncertain Robotic Manipulatorss
...Show More Authors

This paper presents a robust control method for the trajectory control of the robotic manipulator. The standard Computed Torque Control (CTC) is an important method in the robotic control systems but its not robust to system uncertainty and external disturbance. The proposed method overcome the system uncertainty and external disturbance problems. In this paper, a robustification term has been added to the standard CTC. The stability of the proposed control method is approved by the Lyapunov stability theorem.  The performance of the presented controller is tested by MATLAB-Simulink environment and is compared with different control methods to illustrate its robustness and performance.

View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Drug Invention Today
Mucoadhesive oral in situ gel of itraconazole using pH-sensitive polymers: Preparation, and in vitro characterization, release and rheology study