This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.
Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10
... Show MoreThe partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of are derived from the relation between and level density parameter . The formulae used to derive are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on from the Thomas-Fermi formula show a good agreement with the experimental data.
The evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient
In this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction
... Show MoreAbstract:
It is essential to provide health care directly or indirectly based on laboratory tests in order of diagnosing diseases. There is an urgent need for the results of such tests to be accurate and reliable. Therefore, the International Organization for Standardization has prepared special standards for medical laboratories to prove their efficiency, presented in standards 15189: 2012. The aim of the research is to determine the possibility of the Al-alwiya Women's Hospital in meeting the requirements of the standards 15189: 2012, which includes administrative requirements consisting of fifteen items and technical requirements consisting of ten items. The research is important because laboratories shou
... Show MoreThe main aim of the present paper is to study the electric breakdown in a uniform electric discharge system. The system consists of two spheres separated by a dielectric. The dielectric is dry air. Certain boundary conditions are taken into consideration as applied voltage, pressure, and domain. The formation of discharge types as Townsend and streamer under different distance gaps (1, 0.9,0.8, 0.6, 0.4, 0.2, 0.1) mm was sudied. The temperature effect on the breakdown voltages for the discharge process is also included. Seven different temperature steps are chosen in the study. Comsol Multiphysics software is used for the simulation model as a plasma model. Results show that as the gap distance increases the breakdown voltage
... Show MoreIn this paper, the air pollutants concentrations measurements such as Total
Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and
meteorological parameters including temperature (T), relative humidity (RH) and
wind speed & direction were conducted in Baghdad city by several stations
measuring numbered (22) stations located in different regions, and were classified
into (industrial, commercial and residential) stations. The results show that the
concentrations of pollutants (TSP, CO, and CO2) have exceeded the air quality
standards set by World Health Organization (WHO) and Iraqi limitation in the
stations of the Baghdad city. The program (ArcGIS) used to prepare maps of air
pollution in Ba
Link failure refers to the failure between two connections/nodes in a perfectly working simulation scenario at a particular instance. Transport layer routing protocols form an important basis of setting up a simulation, with Transmission Control Protocol and User Datagram Protocol being the primary of them. The research makes use of Network Simulator v2.35 to conduct different simulation experiments for link failure and provide validation results. In this paper, both protocols, TCP and UDP are compared based on the throughput of packets delivered from one node to the other constrained to the condition that for a certain interval of time the link fails and the simulation time remains the same for either of the protocols. Overall,
... Show More