The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate from all terminal units. The hydraulic and energy equations governing the performance of unit solved with the aid of FORTRAN code with considering the following parameters: total water flow rate, chilled water supply temperature, and variable valve opening. It was found that the optimum solution of three-way valve case at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 100%, valve 2: 100% and valve 3: 75%) with total heat rate (987.92 Watt) and standard deviation (1.181E-3). Also, for the two-way valve case the results showed that the optimum condition at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 75%, valve 2: 75% and valve 3: 50%) with total heat rate and standard deviation (717Watt) and (5.69E-4) respectively.
This study introduces a series of single and pile group model tests subjected to lateral loads in . multilayered sand from Karbala, Iraq. The aim of this study is to investigate: the performance of the pile groups subjected to lateral loads; in which the pile batter inclination angle is changed; the effect of pile spacing (s/d) ratio, the influence of using different number of piles and pile group configuration. Results revealed that the performance of single negative (Reverse) Battered piles with inclination of 10° and 20° show a gain of 32% and 76 % in the ultimate lateral capacity over the regular ones. For pile groups, the use of a combination of regular, negative and positive battered piles in
... Show MoreThis paper compares between the direct and indirect georeferencing techniques in Photogrammetry bases on a simulation model. A flight plan is designed which consists of three strips with nine overlapped images for each strip by a (Canon 500D) digital camera with a resolution of 15 Mega Pixels.
The triangulation computations are carried out by using (ERDAS LPS) software, and the direct measurements are taken directly on the simulated model to substitute using GPS/INS in real case. Two computational tests have been implemented to evaluate the positional accuracy for the whole model and the Root Mean Square Error (RMSE) relating to (30) check points show that th
... Show MoreWe conducted an experiment in a greenhouse at the research station belonging to the Department of Plant Protection / Ministry of Agriculture, in Abu Ghraib area during the spring and autumn season 2022-2023, to study the population density of the whitefly on two varieties of sweet pepper plant (Charisma and Sierra Nevada). The experiment was laid out in a randomized complete block design “RCBD” with three replicates for each variety. The results showed that in spring season the population density of
The aim of the present research is to study different protein fractions in sera of children and adolescent with β –thalassemia major and minor and to compare the results with that of healthy control.One hundred fifty children and adolescents were enrolled in this study,including 50 patients with β- thalassemia major , 50 patients with β- thalassemia minor as pathological control group and another apparently 50 healthy individuals as a control group. The age of all studied groups ranged from (4-18)years.Total protein, albumin and immunoglobulins were estimated in sera of all subjects. A Significant decrease was found in the total protein and albumin&nb
... Show MoreForty six Iraqi women with PCOS were involved in this study . They were treated with metformin alone and with antioxidant agents (vitamin E or C).It was found that all patients who treated with metformin or with combination of metformin with antioxidant agents showed significant decrease in hirsutism score. The treatment of metformin with antioxidant agents is of great benefit in treatment of hirsutism in PCOS due to that there was no worsening effect after treatment. This may indicate that antioxidant agents may participate in alleviation of hirsutism so it can be said that oxidative stress may play an important role in developing of hirsutism in PCOS.
Reciprocal Teaching is an interactive method that is used to improve reading comprehension. Using this teaching strategy, teachers and students take turns leading discussions regarding sections of text using the four strategies: predicting, questioning, clarifying and summarizing. This study is an attempt to investigate the effect of using reciprocal teaching on improving female college students' achievement in reading comprehension. To fulfill the aim of the study, the researcher has adopted two null hypotheses: first, there is no significant difference between the achievement of students' who practice the reciprocal teaching technique and that of students who do not practice it. Second, there is no statistically significant difference
... Show MoreIn the 1980s, the French Administration Roads LCPC developed high modulus mixtures (EME) by using hard binder. This type of mixture presented good resistance to moisture damage and improved mechanical properties for asphalt mixtures including high modulus, good fatigue behaviour and excellent resistance to rutting. In Iraq, this type of mixture has not been used yet. The main objective of this research is to evaluate the performance of high modulus mixtures and comparing them with the conventional mixture, to achieve this objective, asphalt concrete mixes were prepared and then tested to evaluate their engineering properties which include moisture damage, resilient modulus, permanent deformation and fatigue characteristics. These pro
... Show More