Preferred Language
Articles
/
alkej-400
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate from all terminal units. The hydraulic and energy equations governing the performance of unit solved with the aid of FORTRAN code with considering the following parameters: total water flow rate, chilled water supply temperature, and variable valve opening. It was found that the optimum solution of three-way valve case at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 100%, valve 2: 100% and valve 3: 75%) with total heat rate (987.92 Watt) and standard deviation (1.181E-3). Also, for the two-way valve case the results showed that the optimum condition at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 75%, valve 2: 75% and valve 3: 50%) with total heat rate and standard deviation (717Watt) and (5.69E-4) respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
HELMINTH PARASITIC FAUNA OF AQUATIC BIRDS IN BAHR AL-NAJAF DEPRESSION, MID IRAQ
...Show More Authors

For two years, from January 1995 till December 1996, a survey on helminth parasites of aquatic birds of Bahr Al-Najaf depression, mid Iraq, was achieved. A total of 663 birds, belonging to 11 species, were captured and examined for helminth parasites. These birds were infected with seven trematodes (Notocotylus gibbus, Cyclocoelum mutabile, Echinostoma chloropodis, Patagifer parvispinosus, Psilochasmus oxyurus, Diplostomum spathaceum and Apharyngostrigea cornu), seven cestodes (Paricterotaenia porosa, Dicranotaenia tsengi, Diorchis brevis, D. inflatus, Tatria acanthorhyncha, T. decacantha and Diplophallus polymorphus) and four nematodes (Capillaria sp., Eustrongylides tubifex, Con

... Show More
View Publication
Publication Date
Wed Oct 24 2018
Journal Name
Al-kindy College Medical Journal
Echocardiographic assessment of Left Ventricular Dyssynchrony in Hypertensive Patients with Normal Systolic Function
...Show More Authors

Background: Normal Left Ventricular systolic function is present in nearly 50% of patients with congestive heart failure, the majority of such patients have systemic hypertension. Recent studies have demonstrated Left Ventricular dyssynchrony among patients with heart failure and normal systolic function. The co-existence between Left Ventricular dyssynchrony and hypertension with normal systolic function (with no clinical evidence of heart failure) is less well understood.

Objective:

To assess the Left Ventricular dyssynchrony among hypertensive patients with normal systolic function by using Tissue doppler imaging.To find out the associations between the LV dyssynchrony and other global

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH3 – H2O SYSTEM
...Show More Authors

This work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia – water).The experiments were carried out in solar absorption system .The system consisted of solar collector generator (0.25 m × 0.25 m × 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92° - 97°) during June 2009, and the minimum evaporator temperature was (5°C - 10°C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Pattern of Congenital Heart Disease In Children Attending Central Teaching Pediatric Hospital, Baghdad
...Show More Authors

Background: Congenital cardiac defects have a wide spectrum of severity in infants. About 30-40% of patients with congenital cardiac defects will be symptomatic in the 1st year of life, while the diagnosis was established in 60% of patients by the 1st month of age.

Objectives: To identify the occurrence of specific types of CHD among hospitalized patients and to evaluate of growth of patients by different congenital heart lesions.

Methods: A retrospective study, done on ninety-six patients (51 male and 45 female) with congenital heart disease (CHD) admitted to central teaching hospital of pediatrics, Baghdad from 1st September 2009 to 30

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Basrah Journal Of Veterinary Research
Prenatal Histological study of the limbs bone onset development in Guinea pig (CaviaCutleri)
...Show More Authors

View Publication
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Influence of grounded electrode area on breakdown current in RF capcitively coupled plasma
...Show More Authors

The influence of the grounded electrode area on the ignition voltage in capcitively coupled radio frequency discharge at 13.56 MHz in argon gas is studied experimentally. The results indicate a systematic decrease of the breakdown voltage with increasing grounded electrode area for the same pd value. Results show that the secondary ionization coefficient γ increases with the increase of grounded electrode area. Furthermore, results also the discharge current at the breakdown voltage increases almost linearly with the increase of electrode area suggesting an almost constant current density.

View Publication Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
International Journal Of Pharmaceutical Research
Effect of Carbamazepine Drug on Liver Ultrastructure in Female White Mice (Mus musculus)
...Show More Authors

Epilepsy is the most common neurological disorder after Alzheimer and other cerebrovascular diseases. Antiepileptic drugs (AED's) are one of the most important methods to prevent epileptic seizers. Antiepileptic drugs can cause damage to the liver which is the largest and most important glandular organ in the body with many other drugs. Carbamazepine (CBZ) is a known anticonvulsant that is widely used and known for a decade, it was used to treat trigeminal neuralgia, bipolar disorder and epilepsy and it can cause hepatotoxicity. In this study female white mice received CBZ suspension at a dose of 20 mg/kg/mouse via gastric gavage for 30 days, tissue samples were collected for scanning electron microscopy. We observed the adverse effects of

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jul 01 2010
Journal Name
Clinical And Experimental Rheumatology
RE-EVALUATION OF PATHERGY TEST IN IRAQI PATIENTS WITH BEHCET'S DISEASE
...Show More Authors

KE Sharquie, R Hayani, J Al-Rawi, A Noaimi, SH Radhy, CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2010

View Publication
Publication Date
Fri Jun 05 2026
Journal Name
Journal Of Systems Science And Mathematical Sciences
SCREENING TESTS FOR DISEASE RISK HAPLOTYPE SEGMENTS IN GENOME BY USE OF PERMUTATION
...Show More Authors

The haplotype association analysis has been proposed to capture the collective behavior of sets of variants by testing the association of each set instead of individual variants with the disease.Such an analysis typically involves a list of unphased multiple-locus genotypes with potentially sparse frequencies in cases and controls.It starts with inferring haplotypes from genotypes followed by a haplotype co-classification and marginal screening for disease-associated haplotypes.Unfortunately,phasing uncertainty may have a strong effects on the haplotype co-classification and therefore on the accuracy of predicting risk haplotypes.Here,to address the issue,we propose an alternative approach:In Stage 1,we select potential risk genotypes inste

... Show More
View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Route Educational And Social Science Journal
THE PARADOX OF A POSTMODERN TECHNOLOGY IN SARAH RUHL’S DEAD MAN’S CELL PHONE
...Show More Authors

View Publication
Crossref