This work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power is 2.15kW, while the experimental measurement revealed that the cooling capacity of the cycle is about 1.98 kW with a relative error of % 0.02. The generator and condensing temperatures are 83 and 30 °C, respectively. The coefficient of performance (COP) of that chiller was in the range of 0.37 to 0.49. The best operating point and the best working conditions were also investigated. The present chiller is superior more than the single stage, two beds adsorption chiller that works on the activated carbon methanol pair that needs a high ambient temperature.
ABSTRACT: Ultimate bearing capacity of soft ground reinforced with stone column was recently predicted using various artificial intelligence technologies such as artificial neural network because of all the advantages that they can offer in minimizing time, effort and cost. As well as, most of applied theories or predicted formulas deduced analytically from previous studies were feasible only for a particular testing environment and do not match other field or laboratory datasets. However, the performance of such techniques depends largely on input parameters that really affect the target output and missing of any parameter can lead to inaccurate results and give a false indicator. In the current study, data were collected from previous rel
... Show MoreThe driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa
Many previous investigations have found quercetin to be a powerful antioxidant and antitumor flavonoid, but its poor bioavailability has limited its use. This current study investigated the effects of two newly synthesized Quercetin Schiff bases containing 2-amino thiadiazole-5-thiol (Q1), and its benzyl derivatives (Q2) on MCF-7 human breast cancer cells. Cell viability and apoptosis were assessed to determine the toxic effects of Q1 and Q2. Cytotoxicity valuation showed that both compounds inhibited MCF-7 cell growth, and lactate dehydrogenase (LDH) activity increased in a dose-dependent aspect compared to the control group. Comet assay results observed that Q1 and Q2 induce more serious DNA damage than the control (untreated cell
... Show MoreThe pumping station became widely used in many fields. Free surface vortices at intakes of pumps are not favorable. It may cause noise, excessive vibration, damage to the pumping structure, reduction in efficiency and flow for hydro-turbines, etc. One of the important problems encountered during the pump intake design is the depth of submergence and other design parameters to avoid strong free-surface vortices formation. This study aims to compute the critical submergence depth with some geometrical and hydraulic limitations by using Computational Fluid Dynamic (CFD) package. The mathematical model was validated with a laboratory model that had been conducted. The model of three intake pipes was investigated under five d
... Show MoreThe use of biopolymer material Chitosan impregnated granular activated carbon CHGAC as adsorbent in the removal of lead ions pb.2+ from aqueous solution was studied using batch adsorption mode. The prepared CHGAC was characterized by Scanning Electronic Microscopy (SEM) and atomic-absorption pectrophotometer. The adsorption of lead ions onto Chitosan-impregnated granular activated carbon was examined as a function of adsorbent weight, pH and
contact time in Batch system. Langmuir and Freundlich models were employed to analyze the resulting experimental data demonstrated that better fitted by Langmuir isotherm model than Freundlich model, with good correlation coefficient. The maximum adsorption capacity calculated f
When it comes to boosting the economy, development, and allocation of financial resources from accessible savings to be employed in all economic sectors (industrial, agricultural, and service), commercial banks in developing and Arab countries are seen as one of the tools. Foreign and domestic investment play critical roles in the economies of both established and developing nations by providing much-needed capital, allowing for the more efficient use of available natural and human resources, and allowing for the more rapid adoption of cutting-edge technologies. Investment success depends on the presence of institutions and capacities of a developed financial and banking type. The significance of this study can be seen in how it exa
... Show MoreThis study included the extraction properties of spatial and morphological basins studied using the Soil and Water Assessment Tool (SWAT) model linked to (GIS) to find the amount of sediment and rates of flow that flows into the Haditha reservoir . The aim of this study is determine the amount of sediment coming from the valleys and flowing into the Haditha Dam reservoir for 25 years ago for the period (1985-2010) and its impact on design lifetime of the Haditha Dam reservoir and to determine the best ways to reduce the sediment transport. The result indicated that total amount of sediment coming from all valleys about (2.56 * 106 ton). The maximum annual total sediment load was about (488.22 * 103 ton) in year 1988
... Show More