This work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power is 2.15kW, while the experimental measurement revealed that the cooling capacity of the cycle is about 1.98 kW with a relative error of % 0.02. The generator and condensing temperatures are 83 and 30 °C, respectively. The coefficient of performance (COP) of that chiller was in the range of 0.37 to 0.49. The best operating point and the best working conditions were also investigated. The present chiller is superior more than the single stage, two beds adsorption chiller that works on the activated carbon methanol pair that needs a high ambient temperature.
The organizations and institutions of the developed countries have given attention to the subject of the knowledge economy by using advanced technology in the function of tax examination because of the important and effective role in ensuring the accuracy of the tax accounting process procedures, But the General Commission of taxes is still using traditional methods in the field of tax examination which affects the performance of its work. This research aims to explain the level of effect on introducing advanced methods of Economics and knowledge represented by advanced communication technology in the field of practicing tax examination function in the General Commission of taxes, A questionnaire has been used as a mea
... Show MoreA histological study showed the wall of the stomach in Pica pica and Herpestes javanicus consists of four layers: mucosa, submucosa, muscularis externa and serosa. Also, the present study showed many differences in the histological structures of the stomach for each in both types. The stomach of P. pica consists of two portions: the proventiculus and gizzard, while the stomach of H. javanicus consists of three portions: cardiac, fundic and pyloric regions. The mucosa layer formed short gastric folds, named plicae. In the proventiculus of P. pica, sulcus is found between each two plicae, but the folds called gastric p
... Show MoreThe aim: To examine the efficiency of different concentrations of Dimethyl sulfoxide (DMSO) and glycerol as a cytoprotectants in protection of human sperms during cryopres¬ervation in this technique. Materials and methods: Thirty oligozoospermic semen samples were used in this study. Samples diagnosed according to WHO 2010 criteria. Sheep’s ovarian follicles obtained from local slaughterhouse and prepared by slicing the ovaries and evacuating the follicular fluid and oocyte. Each semen sample divided into six equal parts, and diluted 1:1 with cryosolution contains 5%, 10%, 15% DMSO or glycerol and injected within the emptied follicles. After freezing and thawing, the semen mixture aspired outside the follicles and sperm concentr
... Show MorePrevious experimental studies have suggested that hot mixed asphalt (HMA) concrete using hydrated lime (HL) to partially replace the conventional limestone dust filler at 2.5% by the total weight of all aggregates showed an optimum improvement on several key mechanical properties, fatigue life span and moisture susceptibility. However, so far, the knowledge of the thermal response of the modified asphalt concrete and thermal influence on the durability of the pavement constructed are still relatively limited but important to inform pavement design. This paper, at first, reports an experimental study of the tensile fatigue life of HMA concrete mixes designed for wearing layer application. Tests were conducted under three different temperatur
... Show MoreThis paper reports test results and describes a numerical investigation of the effectiveness of using carbon fibre reinforced polymer (CFRP) fabrics for strengthening concrete cylinders that have been undamaged and damaged due to heating under preload. The purpose of this research was to investigate whether there is any difference in the performance of CFRP-wrapped cylinders if the wrapping is done under preload, and those for which neither heating, cooling nor wrapping was done under preload. The cylinders were exposed to 30% of maximum load at ambient temperature during heating and cooling before being wrapped under preload. Of 18 Ø 100 × 200 mm identical cylinders, 6 were left as control samples without heating, 12 were exposed t
... Show MoreThe continuous pressure of work and daily life and the increasing financial and social stress that Iraqi women are experiencing (both inside and outside Iraq) is one of the main causes of anxiety, particularly in those of working class women. This group of women carry the burden of carrying out multiple roles and responsibilities at the same time. All this collectively make them more prone to developing anxiety compared to men. In addition, the physiological and psychological nature of women, as females, on top of the other roles in life, like being a wife or mother or daughter or sister, all add extra pressure on women especially for those who are considered as productive working individuals in the society. In order to study the relatio
... Show MoreIn this study, the effect of increasing pump pulse energy and delay time on the energy conversion efficiency of the Potassium Titanyl Phosphate (KTP) crystal at room temperature was investigated. It was found that the higher the pump pulse the greater the efficiency at a certain value of the delay time. Moreover, at the delay time 3.524ns, we found that the efficiency of the conversion of energy increases from 0.0112 to 0.0159. We also observed that the lower delay time between the pump and the probe pulses leads to increase the rate of energy conversion efficiency of the KTP crystal, where the reaches up to 3, which is higher than the value recorded in the absence of a pump pulse. The highest value of the
... Show More