Preferred Language
Articles
/
alkej-369
Recovery of Platinum and Palladium from Scrap Automotive Catalytic Converters
...Show More Authors

Abstract

    

The hydrometallurgical method was used to platinum and palladium leaching with aqua regia solution (3HCl: HNO3). The leaching experiments were designed to obtain the optimum conditions by using Taguchi method with 16 experiments at three different factors (time, temperature and solid to liquid ratio), and each factor has four different levels. In this study, leaching the powder sample of catalytic converter that contains platinum and palladium was conducted on the basis of the formation of chloro complexes platinum and palladium (PtCl62-, PdCl42-) with different concentrations in the acidic solution. The optimum conditions for leaching process are (time = 120 minutes, temperature = 100°C, and solid to liquid ratio = 1/20).The best efficiency for platinum and palladium leaching at these conditions were 97.58%, 93.23%, respectively. After leaching process at optimum conditions, platinum was firstly precipitated in the form of (NH4)2PtCl6 (ammonium chloroplatinate) by adding (5ml/l) of ammonium chloride (NH4Cl) as a precipitant agent .Then, palladium was precipitated in the form of (NH4)2PdClO3 (palladium ammonium chlorate) by adding (5g/l) of sodium chlorate (NaClO3) as a precipitant agent to the remaining solution after the removal of platinum. The best efficiency for platinum and palladium recovery at optimum leaching conditions were 91.94%, and 98.82%, respectively.

                                                                                  

Keywords: Aqua regia, catalytic converter, PGMs, Platinum, Palladium, recovery, catalytic converter, 3HCl:HNO3.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archive
Genetic analysis of sorghum cultivars from USA using SSR markers
...Show More Authors

Scopus (4)
Scopus
Publication Date
Fri Jan 26 2024
Journal Name
Iraqi Journal Of Science
Effect of LPS Extracted from Campylobacter coli on Lymphocyte Transformation
...Show More Authors

Lipopolysaccharide (LPS) of Campylobacter coli was extracted by using
digestive enzyme and hot phenol method. The effect of LPS on lymphocyte
transform was studies by lymphocyte transformation index for twenty blood samples
were collected from apparently healthy control.
The results were showed significant differences (P< 0.05) between samples which
treatrd with phytohemagglutnin PHA (66.1 ± 0.6) and the samples which treated
with LPS of C. coli (74.2 ± 0.8) when compared with control, this lead to suggest
that the LPS extracted from C. coli may play a role as a mitogen to transformed
lymphocytes.

View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Neutron Yield From Gamma Ray Incineration of Radioactive Fission Products
...Show More Authors

The neutron flux in this paper, which is generated as a result of γ incineration of the radioactive fisssion products isotopes has been evaluated .It is obvious from this paper that the neutron flux value depends on the number of incineration nuclei and the nuclear cross-section of the incinerated isotopes, and the neutron flux is directly dependent on γ-ray flux. The neutron flux increases from 1010to 1017n/s.gm as the irradiation flux increases from 1016to 1020 γ/cm2.s. It is concluded that the γ-incineration technique can be used to produce a switchable neutron source of high flux.

View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Sorption Efficiency of Bentonite in Removal Cd from Aqueous Solutions
...Show More Authors

A series of adsorption laboratory experiments were conducted to study the sorption efficiency of bentonite in removal Cd from aqueous solutions. The bentonite was found to be a good receptive to the adsorption of Cd under specific laboratory conditions. The sorption capacity for Cd onto bentonite was investigated through the variation in pH and initial Cd2+ concentration. The sorption efficiency onto bentonite was examined as a function of pH, initial ion concentration, equilibrium reaction time and solid mass/ liquid volume ratio. The maximum sorption (%) of Cd from solutions were determined when solid to liquid ratio is 2 gm of bentonite versus 50 ml solution, the equilibrium reaction time is 50 minute at pH ranges from 5-7. The sorpti

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Synthesis of Some Heterocyclic Compounds Derived from 2-Mercapto Benzoxazole
...Show More Authors

New series of 2-mecapto benzoxazole derivatives (1-20) incorporated into fused to different nitrogen and suphur containing heterocyclic were prepared from 2-meracpto benzoxazole, when treated with hydrazine hydrate to afford 2-hydrazino benzoxazol (1). Compound (1) converted to a variety of pyridazinone andphthalazinone derivatives (2-4) by reaction with different carboxylic anhydride. Also, reaction of (1) with phenyl isothiocyanate and ethyl chloro acetate afforded 3-phenyl-1,3-thiazolidin-2,4-dione-2-(benzoxazole-2-yl-hydrazone) (6). Azomethines (7-10) were prepared through reaction of (1) with aromatic aldehyde, then (7, 8) converted to thaizolidinone derivatives (11, 12). Treatment of (1) with active methylene compounds afforded deriva

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 15 2023
Journal Name
Iraqi Journal Of Science
Sorption efficiency of kaolinte in removal Cd from aqueous solutions
...Show More Authors

Because of the contaminants represented by heavy metals in the aquatic
environment have an adverse effects need to be addressed, therefore, a laboratory
simulation was conducted on Cd using kaolinite that collected from Ga’ara Formation
as considered as a natural sorbent material that can be used to remove heavy metals
from aqueous environments. Mineralogical study was conducted on kaolinite using
X-Ray diffraction (XRD), Scanning Electron Microscope (ESM) and Energy-
Dispersive X-ray Spectroscopy (EDS) for the purpose of investigating the microtexture.
It was found that kaolinite has pure phase of very fine grains with a very little
quantity of quartz and has a number of active sites for adsorption. Chemical an

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Flotation of Chromium Ions from Simulated Wastewater Using Air Microbubbles
...Show More Authors

   A microbubble air flotation technique was used to remove chromium ions from simulated wastewater (e.g. water used for electroplating, textiles, paints and pigments, and tanning leather). Experimental parameters were investigated to analyze the flotation process and determine the removal efficiency. These parameters included the location of the sampling port from the bottom of the column, where the diffuser is located to the top of flotation column (30, 60, and 90 cm), the type of surfactant (anionic, SDS, or cationic, CTAB) and its concentration (5, 10, 15, and 20 mg/L), the pH of the initial solution (3, 5, 7, 9, and 11), the initial contaminant concentration (10, 20, 30, and 40 mg/L), the gas flow rate (0.1, 0.2, 0.3, and 0.5 L/mi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
Movement of Irrigation Water in Soil from a Surface Emitter
...Show More Authors

Trickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter disch

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 20 2019
Journal Name
Journal Of The College Of Education For Women
History of Local Reprimands in the Northwest Caucasus from Ancient Times to the 19th century
...Show More Authors

Ubikh is one of the most important tribes of the Northwest Caucasus and has a long history. Naturally, rebukes are an integral part of the Caucasus region. Their people were able to confront the Russian invasion of their lands like the rest of the Caucasus tribes to defend their existence, freedom and the right to build their independent state, but they were not able to resist the great Russian military progress they achieved on all sides. For the territory that belonged to Persia and the Ottoman Empire and ended the resistance of the Meridian movement in the Northeast Caucasus, the Russians left only the weak resistance of the tribes of the Northwest Caucasus led by the rebuke after Russia managed to eliminate all resistance movements i

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
...Show More Authors

The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, wit

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref