This paper presents a vibration suppression control design of cantilever beam using two piezoelectric patches. One patch was used as an actuator element, while the other was used as a sensor. The controller design was designed via the balance realization reduction method to elect the reduced order model that is most controllable and observable. the sliding mode observer was designed to estimate six states from the reduced order model but three states are only used in the control law. Estimating a number of states larger than that used is in order to increase the estimation accuracy. Moreover, the state estimation error is proved bounded. An optimal LQR controller is designed then using the estimated states with the sliding mode observer, to suppress the vibration of a smart cantilever beam via the piezoelectric elements. The control spillover problem was avoided, by deriving an avoidance condition, to ensure the asymptotic stability for the proposed vibration control design. The numerical simulations were achieved to test the vibration attenuation ability of the proposed optimal control. For 15 mm initial tip displacement, the piezoelectric actuator found able to reduce the tip displacement to about 0.1 mm after 4s, while it was 1.5 mm in the open loop case. The current experimental results showed a good performance of the proposed LQR control law and the sliding mode observer, as well a good agreement with theoretical results.
Zerumbone is a well-known compound having anti-cancer, anti-ulcer, anti-inflammatory and anti-hyperglycemic effects. During its use for the disease treatment, the membrane of erythrocyte can be affected by consumption of this bioactive compound. The current study was the first report of investigation of the hemolytic activities on human erythrocytes and cytotoxic profile of zerumbone. The toxicity of zerumbone on human erythrocytes was determined by in vitro hemolytic assay. Brine shrimp lethality assay was used to evaluate the cytotoxic effect of zerumbone at concentrations 10, 100 and 1000 μg/mL. The human erythrocyte test showed no significant toxicity at low concentrations, whereas hemolytic effect was amplified up to 17.5 % at
... Show MoreDuring the last quarter century, many changes have taken place in the tanks industry and also in the materials that used in its production، while concrete is the most suitable material where concrete tanks has the benefits of strength, long service life and cost effectiveness. So, it is necessary improvement the
conventional concrete in order to adapt the severe environment requirements and as a result high
performance concrete (HPC) was used. It is not fundamentally different from the concrete used in the past, although it usually contains fly ash, ground granulated blast furnace slag and silica fume, as well as
superplasticizer. So, the content of cementitious material is high and the water/cement ratio is low. In this
stu
Summary First: The importance of the study and the need for it: The society is composed of an integrated unit of groups and institutions that seek to achieve a specific goal within a system of salary, and the family remains the most influential institutions on the individual and the unity of society, with the roles and responsibilities of the individual and society, and through the continuation and strength of other social organizations derive their ability On the other hand, any break-up in the institution of the family is reflected negatively on the cohesion of society and its interdependence, and the causes of this disintegration vary from society to another, but family problems remain the main factor in obtaining it. Second: Study Ob
... Show MoreThis study aims to model the flank wear prediction equation in metal cutting, depending on the workpiece material properties and almost cutting conditions. A new method of energy transferred solution between the cutting tool and workpiece was introduced through the flow stress of chip formation by using the Johnson-Cook model. To investigate this model, an orthogonal cutting test coupled with finite element analysis was carried out to solve this model and finding a wear coefficient of cutting 6061-T6 aluminum and the given carbide tool.
The isolates of Staphylococcus aureus were isolated from patients with various infections in hospitals, the isolates were identified and accurately diagnosed by phenotypic examination and biochemical tests, as well Vitek-2, and then genetic detection and diagnosis of many of the pathogenic factors associated with Staphylococcus aureus using conventional polymerase chain reaction (PCR) and testing for association by antibiotic resistance and production of some toxins by Staphylococcus aureus. After performing analysis of statistical, it was set up that the correlation coefficient of the PCR technique using virulence genes, sensitivity test to antibiotics and other virulence factors were significant at p < 0.05, but was insignificant with the
... Show MoreExtensive evaluation of 76 women with polycystic ovary syndrome compared with 25 fertile women as control group was achieved by routine investigations and hormonal study of each female which were done in one period during the menstrual cycle. Then the women with PCOS have been divided into 2 groups according to their menstrual cycle (irregular menstrual cycle) during assessing their hormonal profiles as follow:- 1- (54) Patients with oligomenorrhea. 2- (22) Patients with menorrhea. This study shows that the women with PCOs have different clinical features taken from a history of disease of all of the women. Those features were distributed as follow: 57.92% of them suffer from hirsutism. 19.24% suffer from irregular menstr
... Show MoreThis paper demonstrates an experimental and numerical study aimed to compare the influence of openings of different configurations on the flexural behavior of prestressed concrete rafters. The experimental program consisted of testing six simply supported prestressed concrete rafters; 5 rafters are perforated, and the other one is solid as a reference. All rafters were tested under monotonic midpoint load. The variable which has been investigated in this work was the opening’s configuration (quadrilateral or circular) with the same upper and lower chords depths. The results indicate improvement in the beam flexural behavior using the circular openings compared to the quadrilateral o
Zerumbone is a well-known compound having anti-cancer, anti-ulcer, anti-inflammatory and anti-hyperglycemic effects. During its use for the disease treatment, the membrane of erythrocyte can be affected by consumption of this bioactive compound. The current study was the first report of investigation of the hemolytic activities on human erythrocytes and cytotoxic profile of zerumbone. The toxicity of zerumbone on human erythrocytes was determined by in vitro hemolytic assay. Brine shrimp lethality assay was used to evaluate the cytotoxic effect of zerumbone at concentrations 10, 100 and 1000 μg/mL. The human erythrocyte test showed no significant toxicity at low concentrations, whereas hemolytic effect was amplified up to 17.5
... Show MoreOne of the therapeutic effects of nicotine is used as a protective against developing ulcerative colitis . ulcerative colitis is an inflammatory disease of the bowel affecting the superficial lining mucosa in the rectum and large intestine. In this study nicotine tablets were formulated as modified release tablets targeted to the colon. All formulas were studied for drug release , effect of diluent, retardant concentration, avicel grade,and compression force, the selected formula was then further studied for drug release in 3 different pH ( coated tablets) .The kinetic study revealed acceptable shelf life . Finally the selected formula was given to 6 patients in a pre-liminary clinical study which showed that nicotine c
... Show More