Preferred Language
Articles
/
alkej-309
Helical Piles Embedded in Expansive Soil Overlaying Sandy Soil
...Show More Authors

In this study, the behavior of square helical piles models (5×5) mm2 embedded in expansive soil bed overlaying a layer of sandy soil was investigated. The sand layer 200mm thickness was compacted into four sub layers in a steel container with diameter 400mm in size. Sandy soil layer was compacted into two relative densities 40% and 80%. The bed of ثءحties 40% and 80%.The bed of o00mm in size.Sandy soil layer was compacted into two relative densities 40% and 80%.The bed of oexpansive soil 300mm thickness was compacted into six sub layers on sandy soil layer. Model tests are performed with helical pile length 350mm, 400mm and 450mm and with helix diameter 15mm and 20mm. Also, one helix and double helix were used for these piles. Water was allowed to seep from bottom of sandy soil to reach surface of expansive soil through four sand drains around helical pile. This study revealed that the upward movement of helical piles decreases with increasing depth of embedment in the sandy layer, helix diameter and number of helix. The increase in these parameters provides anchorage against uplifting. Helical piles embedded in sandy soil of relative density (40%) have uplift movement more than helical piles of relative density (80%).

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 29 2024
Journal Name
Sabrao Journal Of Breeding And Genetics
LOW-‎COST SOIL ‎MOISTURE SENSORS’ ASSESSMENT FOR THEIR ACCURACY AFTER CALIBRATION THROUGH THE ‎GRAVIMETRIC METHOD
...Show More Authors

The existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufac

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Baghdad Science Journal
Existence of Fixed Points for Expansive Mappings in Complete Strong Altering JS-metric space
...Show More Authors

The paper aims at initiating and exploring the concept of extended metric known as the Strong Altering JS-metric, a stronger version of the Altering JS-metric. The interrelation of Strong Altering JS-metric with the b-metric and dislocated metric has been analyzed and some examples have been provided. Certain theorems on fixed points for expansive self-mappings in the setting of complete Strong Altering JS-metric space have also been discussed.

View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Materials Science Forum
Spatial Analyzing of the Chemical Soil Properties for the Sanam Mountain- Al Zubair Region South of Basra Province and Diagnosis of its Effects on Soil Qualities Using Remote Sensing Technology and GIS
...Show More Authors

The article discusses the spatial analysis of the chemical soil properties that is a key component of the agriculture ecosystem based on satellite images. The main objective of the present study is to measure the chemical soil properties (total dissolved salts (TDS), Electrical conductivity (EC), PH, and) and the ​spatial variability. On 13 November 2020 (wet season), a total of 12 soil samples were collected in the field through random sampling in the Sanam mountain-Al Zubair region south of Basra province, to contain its soil samples components of minerals and precious elements such as silica and sulfur. From experimental results, the soil sample in the sixth position has the highest concentration of TDS values, reached (5798.4

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Materials Science Forum
Spatial Analyzing of the Chemical Soil Properties for the Sanam Mountain-Al Zubair Region South of Basra Province and Diagnosis of its Effects on Soil Qualities Using Remote Sensing Technology and GIS
...Show More Authors

Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
An Embedded Data Using Slantlet Transform
...Show More Authors

Data hiding is the process of encoding extra information in an image by making small modification to its pixels. To be practical, the hidden data must be perceptually invisible yet robust to common signal processing operations. This paper introduces a scheme for hiding a signature image that could be as much as 25% of the host image data and hence could be used both in digital watermarking as well as image/data hiding. The proposed algorithm uses orthogonal discrete wavelet transforms with two zero moments and with improved time localization called discrete slantlet transform for both host and signature image. A scaling factor ? in frequency domain control the quality of the watermarked images. Experimental results of signature image

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Rehabend
Prediction of impact force-time history in sandy soils
...Show More Authors

Scopus
Publication Date
Mon Sep 01 2008
Journal Name
Journal Of Engineering
GEOTEXTILE AND GEOMEMBRANE USAGE IN AN IRAQI SANDY GEOENVIRONMENT
...Show More Authors

The work in this research presents an experimental and a theoretical study to obtain the effect of using a low permeability geosynthetic material on the longitudinal and lateral coefficients of dispersion. This would have its effect on the contaminants migration through an isotropic, homogenous and saturated soil. The first stage of this research involves the study of the geosynthetic material and in calculating the longitudinal and lateral coefficients of dispersion for an Iraqi sandy soil by using an experimental set-up to simulate the processes. To investigate the effect of using a geosynethtic material on the dispersion coefficients, the test was conducted for each velocity that was used in the experimental work and as follows:  with

... Show More
Publication Date
Thu Mar 22 2018
Journal Name
Environmental Toxicology And Chemistry
Fate, uptake, and distribution of nanoencapsulated pesticides in soil–earthworm systems and implications for environmental risk assessment
...Show More Authors
Abstract<sec><label></label><p>Nanopesticides are novel plant protection products offering numerous benefits. Because nanoparticles behave differently from dissolved chemicals, the environmental risks of these materials could differ from conventional pesticides. We used soil–earthworm systems to compare the fate and uptake of analytical‐grade bifenthrin to that of bifenthrin in traditional and nanoencapsulated formulations. Apparent sorption coefficients for bifenthrin were up to 3.8 times lower in the nano treatments than in the non‐nano treatments, whereas dissipation half‐lives of the nano treatments were up to 2 times longer. Earthworms in the nano treatments accumulated approximately 50% more b</p></sec> ... Show More
View Publication
Scopus (36)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Mon Mar 31 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Evaluation of Sodium Chloride and Acidity Effect on Corrosion of Buried Carbon Steel Pipeline in Iraqi Soil
...Show More Authors

In this work, corrosion parameters were evaluated using potentiodynamic polarization curves. In order to determine corrosion parameters of potential and current density of the interesting metal, carbon steel, environmental conditions of external corrosion of buried carbon steel pipeline in Iraqi soil were prepared in the laboratory using simulated prepared conditions. Solutions of sodium chloride at different concentrations (300, 1100, 1900, 2700, and 3500 ppm) were used. pH of solution were acidic at pH =5, and alkaline at pH = 9. Laboratory conditions were similar to those of Iraqi soil where the pipelines were buried. Temperature was constant at 20 °C. Potentiodynamic polarization curves, of potential vs. log current density, were ob

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archives
Effect of alternate water quality irrigation on pore sizes distribution during drainage in clay loam texture soil
...Show More Authors

Scopus (2)
Scopus