Preferred Language
Articles
/
alkej-304
Produced Water Treatment Using Ultrafiltration and Nanofiltration Membranes
...Show More Authors

The application of ultrafiltration (UF) and nanofiltration (NF) processes in the handling of raw produced water have been investigated in the present study. Experiments of both ultrafiltration and nanofiltration processes are performed in a laboratory unit, which is operated in a cross-flow pattern. Various types of hollow fiber membranes were utilized in this study such as poly vinyl chloride (PVC) UF membrane, two different polyether sulfone (PES) NF membranes, and poly phenyl sulfone PPSU NF membrane. It was found that the turbidity of the treated water is higher than 95 % by using UF and NF membranes. The chemical oxygen demand COD (160 mg/l) and Oil content (26.8 mg/l) were found after treatment according to the allowable limits set by means of world health organization WHO water quality standards. The final composition of SO4-2 (110 mg/l) and NO3 (48.4 mg/l) components within the produced water after treatment were agreed with the permissible limits of WHO, whereas Cl-1 (8900 mg/l) component is not in the allowable limits. Finally by the use of PVC, PES and PPSU hollow fiber membranes; this method is seen to be not sufficient to remove the salinity of the produced water.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
pH-Control Problems of Wastewater Treatment Plants
...Show More Authors

Experimental investigations have been carried out to investigate the pH-control problems of industrial electroplating wastewater treatment plants. The accurate and sensitive PID control system could treat most problem and disturbances in the normal operation of the water treatment. However, conventional treatment was replaced by proprietary treatment agent called a QUASIL which was found to be more effective for a wide range of pH.

View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Performance Evaluation of Al-Karkh Water Treatment Plant Using Model-driven and Data-Driven Models
...Show More Authors
Abstract<p>There is a great operational risk to control the day-to-day management in water treatment plants, so water companies are looking for solutions to predict how the treatment processes may be improved due to the increased pressure to remain competitive. This study focused on the mathematical modeling of water treatment processes with the primary motivation to provide tools that can be used to predict the performance of the treatment to enable better control of uncertainty and risk. This research included choosing the most important variables affecting quality standards using the correlation test. According to this test, it was found that the important parameters of raw water: Total Hardn</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Image restoration using regularized inverse filtering and adaptive threshold wavelet denoising
...Show More Authors

Although the Wiener filtering is the optimal tradeoff of inverse filtering and noise smoothing, in the case when the blurring filter is singular, the Wiener filtering actually amplify the noise. This suggests that a denoising step is needed to remove the amplified noise .Wavelet-based denoising scheme provides a natural technique for this purpose .

                In this paper  a new image restoration scheme is proposed, the scheme contains two separate steps : Fourier-domain inverse filtering  and wavelet-domain image denoising. The first stage is Wiener filtering of the input image , the filtered image is inputted to adaptive threshold wavelet

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Estimating concentration of toxic ions Arsenic in water by using Photonic Crystal Fiber based on Surface Plasmon Resonance (SPR)
...Show More Authors

In this work, an enhanced Photonic Crystal Fiber (PCF) based on Surface Plasmon Resonance (SPR) sensor using a sided polished structure for the detection of toxic ions Arsenic in water was designed and implemented. The SPR curve can be obtained by polishing the side of the PCF after coating the Au film on the side of the polished area, the SPR curve can be obtained. The proposed sensor has a clear SPR effect, according to the findings of the experiments. The estimated signal to Noise Ratio (SNR), sensitivity (S), resolution (R), and Figures of merit (FOM) are approaching; the SNR is 0.0125, S is 11.11 μm/RIU, the resolution is 1.8x〖10〗^(-4), and the FOM is 13.88 for Single-mode Fiber- Photonic Crystal Fiber- single mode Fiber (SMF-P

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Classical and Statistical Optimization of Medium Composition for Promoting Prodigiosin Produced by Local Isolate of Serratia Marcescens
...Show More Authors

Prodigiosin is a ‘natural red pigment produced by Serratia marcescens which exhibits immunosuppressive and anticancer properties in addition to antimicrobial activities. This work presents an attempt to maximize the production of prodigiosin by two different strategies: one factor at time (OFAT) and statistical optimization. The result of OFAT revealed that sucrose and peptone were the best carbon and nitrogen sources for pigment production with concentration of prodigiosin of about 135 mg/ L. This value was increased to 331.6mg/ L with an optimized ratio of C/N (60:40) and reached 356.8 with pH 6 and 2% inoculum size at end of classical optimization. Statistical experimental design based on Response surface methodology was co

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Engineering
Water Treatment With Conventional and Alternative Coagulants: A Review
...Show More Authors

There is no access to basic sanitation for half the world's population, leading to Socioeconomic issues, such as scarcity of drinking water and the spread of diseases. In this way, it is of vital importance to develop water management technologies relevant to the target population. In addition, in the separation form of water treatment, the compound often used as a coagulant in water treatment is aluminum sulfate, which provides good results for raw water turbidity and color removal. Studies show, however, that its deposition in the human body, even Alzheimer's disease, can cause serious harm to health and disease development. The study aims to improve the coagulation/flocculation stage related to the amount of flakes, i

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Renewable energy between limited use and treatment of the electricity crisis in Iraq
...Show More Authors

The electric energy is one of the most important renewable energies used in the world as it is the main source for sustainable development and economic development through its use in (production, transport and distribution), and in Iraq, the electric power sector has suffered from many problems and obstacles, as providing electric current is one of the most prominent difficulties and challenges That successive governments and residents have faced since the early nineties of the last century and are still ongoing, and that Iraq has all the climatic conditions for developing the work of the electricity system from renewable energies such as solar and hydroelectric energy, as well as gas fields that have become a Basic pillar of pow

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
...Show More Authors

Abstract

    In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at d

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Materials Today Sustainability
Structure and performance of polyvinylchloride microfiltration membranes improved by green silicon oxide nanoparticles for oil-in-water emulsion separation
...Show More Authors

View Publication
Scopus (8)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.: STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.
...Show More Authors

Steps were taken to obtain the Kojic acid crystals from local fungal isolation A. flavus WJF81 by separating the fermentation products from the fungus mycelium from the production plant at the centrifuge at a speed of 5000 cycles for 10 minutes. The extraction was followed by ethyl acetate then supernatant concentrate by using rotary evaporator, and dried with heat oven 37ºC. Long, yellowish, pristine acid crystals were obtained that examined the optical microscope with a magnification force of 10x and 40x. The melting point of kojic acid was determined between 152.9-153.5 °C Results of the diagnosis of Kojic acid by applying High pressure liquid chromatography HPLC technique showed that the acid was at one peak, which was close to the

... Show More
View Publication Preview PDF