Preferred Language
Articles
/
alkej-301
Experimental Investigations Performance for (VCC) Using 2-Way (PFCV) Type (2FRE)
...Show More Authors

In modern hydraulic control systems, the trend in hydraulic power applications is to improve efficiency and performance. “Proportional valve” is generally applied to pressure, flow and directional-control valves which continuously convert a variable input signal into a smooth and proportional hydraulic output signal. It creates a variable resistance (orifice) upstream and downstream of a hydraulic actuator, and is meter in/meter out circuit and hence pressure drop, and power losses are inevitable. If velocity (position) feedback is used, flow pattern control is possible. Without aforementioned flow pattern, control is very “loose” and relies on “visual” feed back by the operator. At this point, we should examine how this valve works and how can use it in electro-hydraulic circuit designs.

In this paper, constructed and compared velocity control cylinder (VCC) by using a proportional flow control valve (PFCV) and with a fine throttle valve. With the aid of a check valve and that check valve, the proportional valve can be made to act in the “lift” direction, and the fine throttle in the “lower” direction. As with all proportional valves, there is also some hysteresis in a proportional flow control valve. The valve used in this work with a hysteresis of <±1% of  . The repetition accuracy is quoted in data sheet as < 1% of . The inferential results are good, acceptable and useful for designers which are working at hydraulic proportional field.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Doppler Phenomenon on the Speed of Blood Flow
...Show More Authors

This research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of  disease and morbidity  of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of

... Show More
View Publication Preview PDF
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Adenosine Deaminase Activity in type 1 and type 2 Diabetes Mellitus
...Show More Authors

         Serum adenosine deaminase (ADA) activity was determined in 30 blood sample of type 1 diabetic individuals 30 blood sample for the type 2 and 15 normal children as a control for type 1 15 normal adults as control for type 2. The mean ADA activity and specific activity in type 1 was (8.85± 5.55 U/mg of protein) which is compared with control (32.11± 1.54 U/mg of protein) while in type 2 was (48.46±11.91 U/mg of protein) is compared with control (5.18± 2.27 U/mg of protein ). We conclude that the altered blood level of ADA activity may help in predicting immunological dysfunction in diabetic individuals and also has a prognostic value.

View Publication Preview PDF
Publication Date
Sun Jul 02 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
role of liver /kiudney microsomal antibody type 1 with type 2-autoimmune hepatitis
...Show More Authors

Background:

View Publication Preview PDF
Crossref
Publication Date
Sun Oct 02 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Glycemic control in children and adolescents with type 1 diabetes mellitus in post conflict Iraq: a primary report
...Show More Authors

Background: Type 1 diabetes mellitus (T1DM) is a common disease in childhood. A linear relation between glycemic control (HbA1c < 7) and onset or progression of complication was detected. Only few individuals achieve glycemic control.
Objective: To estimate the glycemic control among diabetic children attending tertiary center.
Methods: All diabetic children registered in the diabetic consultancy clinic in Children Welfare Teaching hospital (298) were included in the study. Case records were reviewed and information on demography, weight and height, age at diagnosis and HbA1c was requested.
Results: Out of the total, 23.8% diabetic children had glycemic control. Glycemic control was decreasing with age (p=0.001), significantl

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Genetic Algorithm Based PID Controller Design for a Precise Tracking of Two-Axis Piezoelectric Micropositioning Stage
...Show More Authors

 In this paper, an intelligent tracking control system of both single- and double-axis Piezoelectric Micropositioner stage is designed using Genetic Algorithms (GAs) method for the optimal Proportional-Integral-Derivative (PID) controller tuning parameters. The (GA)-based PID control design approach is a methodology to tune a (PID) controller in an optimal control sense with respect to specified objective function. By using the (GA)-based PID control approach, the high-performance trajectory tracking responses of the Piezoelectric Micropositioner stage can be obtained. The (GA) code was built and the simulation results were obtained using MATLAB environment. The Piezoelectric Micropositioner simulation model with th

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
19th International Conference On Methods And Models In Automation And Robotics (mmar) 2014
A PSO-optimized type-2 fuzzy logic controller for navigation of multiple mobile robots
...Show More Authors

Scopus (20)
Crossref (17)
Scopus Crossref
Publication Date
Mon Dec 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Performance of Gas Induction in a Dual – Impeller Agitated Bioreactor
...Show More Authors

The rate of gas induction was measured in gas-inducing type mechanically agitated contactors provided with two impellers. A reactor of 0.5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of two equal diameter stirrers; the top impeller is shrouded-disk/curved-blade turbine with six evacuated bending blades, while the bottom impeller was disk turbine. The impeller speed was varied in the range of 50 to 800 rpm. The ratio of impeller diameter to tank diameter (D/T) and the submergence (S) of upper impeller from the top were varied. The effects of clearance of lower impeller from the tank bottom (C2) an

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Improve the performance of solar cells using new designs for pelvic center wheel Type V compound mirrors encased by Vernil glasses
...Show More Authors

Design and build a center basins new p-type four mirrors were studied its effect on all parameters evaluating the performance of the solar cell silicon in the absence of a cooling system is switched on and noted that the efficiency of the performance Hzzh cell increased from 11.94 to 21 without cooling either with cooling has increased the efficiency of the

View Publication Preview PDF
Publication Date
Sun Jan 02 2011
Journal Name
Journal Of The Faculty Of Medicine Baghdad
QT interval analysis in type 2 diabetic patients
...Show More Authors

Background: The electrocardiographic QT interval has been extensively studied in diabetes mellitus. Recently, there has been increasing interest in the relationship between diabetes and QT abnormalities .The QT interval, which is easily obtained from a standard resting electrocardiogram( ECG), reflected the total duration of ventricular myocardial depolarization and repolarization. The heart rate corrected QT interval (QTc) by Bazett's formula on the electrocardiogram has been proposed as a risk factor for ventricular arrhythmias in diabetes mellitus. Dispersion of QT(QTd) is defined as the difference between maximum and minimum QT interval QT interval on 12 lead ECG, which reflected spatial ventricular

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Load and Pressure Distribution on Wing with Wake Rollup for Low Speed Aircraft
...Show More Authors

The presented work shows a preliminary analytic method for estimation of load and pressure distributions on low speed wings with flow separation and wake rollup phenomena’s. A higher order vortex panel method is coupled with the numerical lifting line theory by means of iterative procedure including models of separation and wake rollup. The computer programs are written in FORTRAN which are stable and efficient.

      The capability of the present method is investigated through a number of test cases with different types of wing sections (NACA 0012 and GA(W)-1) for different aspect ratios and angles of attack, the results include the lift and drag curves, lift and pressure distributions along the wing s

... Show More
View Publication Preview PDF