Design & Implementation of High Switching & Low Phase Noise Frequency Synthesizer
...Show More Authors

This research  describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc

  The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar &  reference divider in single chip. Therefore our system consists of  a single chip contains (low phase noise PFD, charge pump, prescalar  & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip is used to provide the following properties :

  • Low power consumption.
  • Small size, light weight.
  • Flexibility in selecting crystal oscillator frequencies to fit into the system frequency planning.
  • High reliability.

The application of this synthesizer  in frequency hopping systems, satellite communications & radar because it has high switching speed  ,low phase noise & low spurious level.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 15 2024
Journal Name
Journal Of Ethnicity In Substance Abuse
Knowledge, attitude, and frequency of hookah smoking among medical students
...Show More Authors

Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Effect of frequency Chirp on the black and gray solitions
...Show More Authors

the behavior of the first-order black and gray solitons propagtedin optical fiber in the presence of frequency chirp is studied analytically and numerically results show that phase profile of black solitons changes abruptly

View Publication Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Frequency of Antineutrophil Cytoplasmic Antibodies (ANCA) in Some Autoimmune Diseases
...Show More Authors

Anti-Neutrophil Cytoplasmic Antibodies (ANCA) are a heterogeneous group of autoantibodies with a broad spectrum of clinically associated diseases. The diagnostic value is established for Proteinase 3 (PR3)-ANCA as well as Myeloperoxidase (MPO)-ANCA. To estimate the frequency of anti-neutrophile cytoplasmic antibodies (ANCA) in sera from a group of Iraqi patients with some autoimmune diseases compared with a healthy control group. Serum samples were collected from one hundred patient, 47 males and 53 females; with age range of 16-70 years; 20 specimens from patients with systemic lupus erythematosus (SLE), 30 from patients with ulcerative colitis (UC), and 50 from patients with rheumatoid arthritis (RA). A group of 40 apparently healthy b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 30 2021
Journal Name
Al-kindy College Medical Journal
Impact of different sources of noise exposure on hearing impairment: A cross- sectional study
...Show More Authors

Background: Mental health is integrated into PHC as a strategy of WHO to fill the gap in mental health treatment. Part of this strategy needs a level of task shifting so that mental health care is provided by different level of PHC workers and not only specialists such as psychiatrists and psychologists.

Objectives: To assess the knowledge and attitudes of family doctors regarding the provision of psychological health in PHCC and if there is an association between the certificates of these family doctors and their Knowledge and attitudes to psychological health.

Subjects and Methods:  A cross-sectional descriptive study with analytic elements was conducted in 8 famil

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
An Enhanced Approach of Image Steganographic Using Discrete Shearlet Transform and Secret Sharing
...Show More Authors

Recently, the internet has made the users able to transmit the digital media in the easiest manner. In spite of this facility of the internet, this may lead to several threats that are concerned with confidentiality of transferred media contents such as media authentication and integrity verification. For these reasons, data hiding methods and cryptography are used to protect the contents of digital media. In this paper, an enhanced method of image steganography combined with visual cryptography has been proposed. A secret logo (binary image) of size (128x128) is encrypted by applying (2 out 2 share) visual cryptography on it to generate two secret share. During the embedding process, a cover red, green, and blue (RGB) image of size (512

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
"Using Markov Switching Model to Investigate the Link between the Inflation and Uncertain Inflation in Iraq for the periods 1980-2010"
...Show More Authors

In this paper we use the Markov Switching model to investigate the link between the level of Iraqi inflation and its uncertainty; forth period 1980-2010 we measure inflation uncertainty as the variance of unanticipated  inflation. The results ensure there are a negative effect of inflation level on inflation uncertainty and  all so there are a positive effect of inflation uncertainty on inflation level.                                                   &nbsp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 06 2023
Journal Name
Karbala International Journal Of Modern Science
Improving the BURT’s Sensitivity using Noise Calibration Unit via Crab Nebula Observations
...Show More Authors

Radio observations from astronomical sources like supernovae became one the most important sources of information about the physical properties of those objects. However, such radio observations are affected by various types of noise such as those from sky, background, receiver, and the system itself. Therefore, it is essential to eliminate or reduce these undesired noise from the signals in order to ensure accurate measurements and analysis of radio observations. One of the most commonly used methods for reducing the noise is to use a noise calibrator. In this study, the 3-m Baghdad University Radio Telescope (BURT) has been used to observe crab nebula with and without using a calibration unit in order to investigate its impact on the sign

... Show More
Preview PDF
Scopus Crossref
Publication Date
Sun Aug 06 2023
Journal Name
Karbala International Journal Of Modern Science
Improving the BURT’s Sensitivity using Noise Calibration Unit via Crab Nebula Observations
...Show More Authors

Radio observations from astronomical sources like supernovae became one the most important sources of information about the physical properties of those objects. However, such radio observations are affected by various types of noise such as those from sky, background, receiver, and the system itself. Therefore, it is essential to eliminate or reduce these undesired noise from the signals in order to ensure accurate measurements and analysis of radio observations. One of the most commonly used methods for reducing the noise is to use a noise calibrator. In this study, the 3-m Baghdad University Radio Telescope (BURT) has been used to observe crab nebula with and without using a calibration unit in order to investigate its impact on the sign

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Engineering
Software Implementation of Binary BCH Decoder Using Microcontroller
...Show More Authors

In this paper a decoder of binary BCH code is implemented using a PIC microcontroller for code length n=127 bits with multiple error correction capability, the results are presented for correcting errors up to 13 errors. The Berkelam-Massey decoding algorithm was chosen for its efficiency. The microcontroller PIC18f45k22 was chosen for the implementation and programmed using assembly language to achieve highest performance. This makes the BCH decoder implementable as a low cost module that can be used as a part of larger systems. The performance evaluation is presented in terms of total number of instructions and the bit rate.

 

 

View Publication Preview PDF
Publication Date
Tue Nov 01 2011
Journal Name
Journal
Frequency of autoimmune diseases and estimation of P53 among vitiligo patients
...Show More Authors

KE Sharquie, AA Noaimi, SY Mohsin, 2011 - Cited by 4

View Publication